background image

VePAL V300

Quick Reference Guide

V-SAM

Configuration 

(cont’d)

15. Service Acceptance Parameters: Defines the threshold 

values for test Pass/Fail

 

Enter FLR (Frame Loss Rate) threshold

 

Optional Enter FTD (Frame Transfer Delay) threshold

 

Optional Enter IFDV (Inter Frame Delay Variation) threshold

 

Optional Enter AVAIL (availability) threshold. The service 
becomes unavailable if more than 50% of the frames 
are errored or missing in a one second interval.

16. Before starting the V-SAM test, a loopback at the far end is 

required. Choose one of the following options:

 

Place a physical loop at the far end (for Layer 1 tests)

 

Setup a remote VePAL unit in Loopback mode, already 
preconfigured at the far end.

 

Setup a remote VePAL unit in loopback mode using 
control commands (local and remote units need to be 
configured with IP addresses). Tap the               button.

 

802.1ag OAM loopbacks are also supported (if 802.1ag 
software option enabled). Tap the               button.

Note: If the far end test partner is already in loopback mode (preconfigured 

locally at the far end), there is no need to make use of the Control window

Содержание V-SAM VePAL V300

Страница 1: ...Quick Reference Guide VePAL V300 V SAM The Verification Experts Common Features...

Страница 2: ...t the service is compliant to its bandwidth profile and service acceptance criteria and is broken down into two phases Phase 1 Service Configuration test The services running on the same line are test...

Страница 3: ...nto three presentation areas LEDs Displays soft LEDs associated with Errors and Alarms Tools Management port IP connection status Fiber Scope ReVeal EZ Connect Utilities Applications Help Settings Fil...

Страница 4: ...commands to a remote unit To establish an IP connection from the Home menu tap the IP menu and configure the connection for static or DHCP If static configure the Local IP Subnet and Gateway IP addre...

Страница 5: ...t Setup screen 10 100 1000Base T port settings Auto Negotiation on or off forced speed and duplex and Flow Control 1000 Base X port settings Auto Negotiation on or off and Flow Control 10GE port setti...

Страница 6: ...From the Home menu tap on the V SAM menu 8 Configure the General tab Select the number of Services to be tested up to 8 on 1GE and up to 10 on 10GE Select if the results should be displayed in ULR or...

Страница 7: ...reen To modify the settings for whether the V SAM test continues or stops at a test failure for STOP V SAM on TEST FAILURE choose Enable or Disable If Disable is selected V SAM tests will continue eve...

Страница 8: ...tag if applicable Use to copy the Header settings from one specific Service number to one or more other Service numbers 12 Configure the MAC address for Layer 2 IP address for Layer 3 IP header VLAN...

Страница 9: ...end frames that will be forwarded on a best effort basis but may be dropped in the event of congestion within the network Enable Disable Traffic Policing Test this test ensures that traffic in excess...

Страница 10: ...erval 16 Before starting the V SAM test a loopback at the far end is required Choose one of the following options Place a physical loop at the far end for Layer 1 tests Setup a remote VePAL unit in Lo...

Страница 11: ...ils use the Service tabs CIR test The test passes if all measured values are below the thresholds configured If a threshold is disabled it will not be evaluated towards pass fail criteria CIR EIR test...

Страница 12: ...curate However we reserve the right to change any contents at any time without notice We accept no responsibility for any errors or omissions In case of discrepancy the web version takes precedence ov...