7.1.1.2 Interface:
Allows the user to select the following:
Clock source:
Internal:
The clock for the transmitter is derived from the internal clock. The internal clock has an accuracy of +/- 3.5ppm conforming to G.812 recommendations.
External:
2MHz, 2Mbit/s
Termination:
Terminated, Monitor, Bridge
Line code:
HDB3, AMI
RX
(
Received):
The clock for the transmitter is derived from the received signal and the jitter of the incoming signal is suppressed.
Offset:
The clock for the transmitter is derived from internal clock generator. It can change the offset while measurements are running. Use the numeric key to
increase and decrease the frequency shift, up to 0.01ppm. Frequency offset: ± 50ppm with 1, 0.1, 0.01ppm resolution.
Interface Menu
Interface External Clock
7.1.1.3 Structure:
Allows the user to configure lower order mapping and the channel number.
Structure Menu