Auto Negotiation:
On or Off. Matches the test set's negotiation settings to those of the link partner.
Speed (only when Auto Negotiation is Off):
10 Mbps, 100 Mbps, or 1000 Mbps.
Duplex (only when Auto Negotiation is Off):
Half or Full.
Advertisement (only when Auto Negotiation is On):
Default-All or Custom. Custom options include 10/100/1000M/Half or
10/100/1000M/Full.
Flow Control:
TX On, RX On, Both On, or Off.
When flow control is On, the test set will respond to pause frames received by the link partner by adjusting the transmit
rate.
When flow control is Off, the test set ignores all incoming pause frames from the link partner and continues transmitting
at the configured transmit rate.
MDIX:
Off, On, or Auto. When MDIX is set to Auto, the test set detects the required cable connection type and configures the
port connection properly for interfacing the partner device, eliminating the need for crossover cables.
Clock Offset (ppm):
The frequency may be offset in parts per million.
Transmit clock offset (10/100/1000Base-T only)
: Disabled or Enabled. Due to hardware limitation, transmit clock offset is only
valid when PHY is working on Master mode. Clock offset measurement is only valid when PHY is working on Slave mode.
PHY working mode
: Master or Slave.
Synchronous Ethernet (SyncE):
Disabled or Enabled. When Enabled, makes the signal traceable to an internal or external
reference clock.
Note
: For information on configuring SyncE operation, see Port Page 2 - Mode Selection in the Synchronous Ethernet section.
1GE Ethernet Port Setup
Tap
Apply
to save changes. Tap
Discard
to revert to previous selections.
10 GE Port
10GE Mode:
LAN, WAN, 10GBase-T
WIS Mode
(only available in WAN mode): SDH or SONET
Flow Control:
Enable is selected as the default option
Clock Offset (ppm):
The frequency is offset in parts per million
Link Fault Response:
Disable or Enable (also enables Local link and failure, remote, failure). Link Fault Response turns on the
Local and Remote fault counter. Local and Remote Faults are caused by a link down (loss pf PCS alignment)/loss of signal
condition. The unit that detects (RX) the link down/loss of signal condition will declare a Local Fault. It will then send a Remote
Fault message to the other unit at the far end. When the far end unit receives the remote fault message it stops sending frames
to the unit with the local fault.
10 GE Dual Ethernet Port Setup
RXT-3900 e-Manual D07-00-111P Rev A00
Содержание RXT3900
Страница 1: ...RXT 3900 e Manual D07 00 111P Rev A00...
Страница 19: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Страница 35: ...Tx Structure Setup Graphical Mode Tx Payload Setup Tx Pattern Setup RXT 3900 e Manual D07 00 111P Rev A00...
Страница 50: ...RXT 3900 e Manual D07 00 111P Rev A00...
Страница 74: ...RXT 3900 e Manual D07 00 111P Rev A00...
Страница 75: ...RXT 3900 e Manual D07 00 111P Rev A00...
Страница 119: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Страница 240: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Страница 282: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Страница 294: ...Go back to top Go back to TOC 13 15 IP Monitoring RXT 3900 e Manual D07 00 111P Rev A00...
Страница 296: ...Net Wiz Trace Route Setup Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Страница 363: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Страница 377: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...