5.4 RFC 2544 Conformance Testing
Starting / Stopping a RFC2544 Measurement
Overview:
RFC 2544 recommendations are well accepted in the test and measurement industry for network performance testing. The RFC
2544 test suite consists of and performs a set of four automated tests (throughput, latency, frame loss, and burst or back-to-back) to
qualify the performance of a network link under test. The tests are especially popular for the verification of network links with certain
service level agreements (SLA).
The following settings must be configured prior to RFC 2544 testing:
Test layer (Layer 2, 3, & 4)
Frame header (PBB, MAC, VLAN, IP, UDP, and Data)
Test frames selection
Pass/fail thresholds (optional)
Far-end unit loop control
Throughput
Latency
Frame loss
Burst (back-to-back)
RFC 2544 Setup - Layer 2 parameters
RXT-6400_Module_Manual
Page 38 of 119
Содержание RXT-6400
Страница 1: ......
Страница 14: ...100 GE Setup Setup Clock Source Clock Offset RXT 6400_Module_Manual Page 14 of 119 ...
Страница 87: ...File Manager Saved Results Go back to top Go back to TOC RXT 6400_Module_Manual Page 87 of 119 ...
Страница 118: ...Go back to top Go back to TOC RXT 6400_Module_Manual Page 118 of 119 ...