Veeder-Root V454501 Скачать руководство пользователя страница 5

1. Upper Display

2. Lower Display

3. Program

4. Preset Output Annunciator

(ON when active)

5. Reset Key

6. Enter

7. Next Key

8. Down

9. Preset
Annunciator

(ON when Preset
value is shown in the
lower display)

NOTE

To abort changes to a
parameter value, press
Down and Next together
instead of 

ENT

.

IMPORTANT

In Edit Mode, you must
press the 

ENT

 key within

15 seconds of the last
keypress, otherwise the
new data will be lost and
the old data will be
restored.

O P E R A T I O N

Down key

Operator Mode:

 Used to change the

currently-selected (flashing) digit.

Depressing this key will decrement the

value (wrap-around from 0 to 9). If the

key is held continuously, the value will

decrement at the rate of 2/sec.

Program Mode:

 Used to advance from

one parameter to the next. Once a

parameter value has been selected for

editing (through use of the Next key),

depressing this key will decrement the

value (wrap-around from 0 to 9). If the

key is held continuously, the value will

decrement at the rate of 2/sec.

Configuration Mode:

 Used to advance

from one parameter to the next.

Next key

Operator Mode:

 Used to select a

parameter for editing (left-most digit will

start to flash) and to move between the

digits. Once the proper digit is selected

(flashing) with the Next key, its value can

be altered through use of the Down key.

Program Mode:

 Used to select a

parameter for editing (left-most digit will

start to flash) and to move between the

digits. Once the proper digit is selected

(flashing) with the Next key, its value can

be altered through use of the Down key.

For Decimal Point Position, this key

scrolls through the available choices.

Configuration Mode:

 Used to select a

parameter for editing and to scroll through 

available choices.

ENT key

Operator Mode/Program Mode:

Confirms an edited value (display will

cease flashing after the 

ENT

 key is

depressed).

Configuration Mode:

 Confirms

setting/value selection (display will cease

flashing after the 

ENT

 key is depressed).

RST key

Operator Mode/Program Mode:

 Resets 

count value to either zero or Preset value

(based on the setting of the Count

Direction parameter in Configuration

Mode). Also releases latched outputs.

Configuration Mode:

 Exits

Configuration Mode when held down for 2 

seconds.

NOTE:

 The 

RST

 key will not be active

unless enabled in Configuration Mode.

For information on Operator Mode, see Page 6.
For information on Program Mode, see Page 7.
For information on Configuration Mode, see Page 8.

Содержание V454501

Страница 1: ...e V454500 family of preset counters combines state of the art circuitry and electronic assembly techniques with an ergonomic package design that results in the most cost effective high performance cou...

Страница 2: ...s display of Count and Preset data Red LED display Annunciators show input display and output status Ergonomic Keypad Simple key sequences to view and edit Presets Front Panel Reset key can be disable...

Страница 3: ...Current Sinking NPN Count Inputs Connect Add count input to Terminal 2 A and or Subtract count input to Terminal 3 B see below In Configuration Mode set PuLL parameter to YES and for Add Subtract oper...

Страница 4: ...rom the front of the mounting panel and hold the Counter lightly in position against the panel Ensure that the panel gasket is not distorted and that the Controller is positioned squarely against the...

Страница 5: ...ting left most digit will start to flash and to move between the digits Once the proper digit is selected flashing with the Next key its value can be altered through use of the Down key Program Mode U...

Страница 6: ...ts are as required press the ENT key to confirm the changes the display will stop flashing IMPORTANT You must press the ENT key within 15 seconds of the last keypress when entering a new value otherwi...

Страница 7: ...e digits will flash use Next key to select each digit to be adjusted and adjust digit value using Down key When adjustment is complete press ENT key to exit Edit Mode digits will become static 2 To ad...

Страница 8: ...a parameter use the Down key to step through the parameters when the desired parameter description is shown in the upper display press the Next key to enter Edit Mode and to scroll through the availab...

Страница 9: ...medium speed 25 0ms low speed Control Inputs Remote Reset Terminal 5 edge sensitive Program Mode Terminal 6 level sensitive Input Voltage High 3 0V or open Low 2 0V Input Impedance 4 7k to V Input Re...

Страница 10: ...10 N O T E S...

Страница 11: ...11 N O T E S...

Страница 12: ...Neuhausen ADF Tel 49 71589003 0 Fax 49 71589003 32 In Brazil Veeder Root do Brasil Rua Ado Benatti No 92 Caixa Postal 8343 CEP 05037 010 S o Paulo Tel 55 118612155 Fax 55 118611982 1675 N Delany Road...

Отзывы: