To enter Configuration Mode,
power-down the Counter and
remove it from its housing.
Change the position of the link
jumper on the CPU PCB (the
actual position is irrelevant, as
long as the position is
changed). Replace the Counter
in its housing and power-up.
The PGM indicator will flash
whilst the Counter is in
Configuration Mode.

Parameter

Counter Speed

Input Operation

Panel Reset Key

Auto Reset

Input Pull-Ups

Count Direction

Lock Strategy

Parameter

Description

(Upper Display)

Available Settings

To exit Configuration Mode, either momentarily remove power from the Counter
or press and hold down the 

RST

 key for at least two seconds.

To edit a parameter, use the Down key to step through the parameters; when the desired

parameter description is shown in the upper display, press the Next key to enter Edit Mode

and to scroll through the available settings. When desired setting is shown, press the 

ENT

key. The Configuration Mode parameters/settings, in order of appearance, are:

LOCK STRATEGY:

None

= No security; all parameters available through regular methods of access

Preset Lock

= Presets become Read Only

Partial Lock

= Output ON times are Read Only

Both

= Operator Mode parameters and Output ON times are Read Only.

Down key steps

through parameters

Counter

(Top view)

20Hz

S E T   U P

200Hz

10kHz

A-B

(Add/Subtract)

Quadrature

(bi-directional)

Enable

Disable

Enable

Disable

Yes

(current-sinking

No

(current-sourcing

Up-countin

Down-countin

None

Preset

Lock

Partial

Program

Lock

Preset &
Program

Lock

Содержание V454501

Страница 1: ...e V454500 family of preset counters combines state of the art circuitry and electronic assembly techniques with an ergonomic package design that results in the most cost effective high performance cou...

Страница 2: ...s display of Count and Preset data Red LED display Annunciators show input display and output status Ergonomic Keypad Simple key sequences to view and edit Presets Front Panel Reset key can be disable...

Страница 3: ...Current Sinking NPN Count Inputs Connect Add count input to Terminal 2 A and or Subtract count input to Terminal 3 B see below In Configuration Mode set PuLL parameter to YES and for Add Subtract oper...

Страница 4: ...rom the front of the mounting panel and hold the Counter lightly in position against the panel Ensure that the panel gasket is not distorted and that the Controller is positioned squarely against the...

Страница 5: ...ting left most digit will start to flash and to move between the digits Once the proper digit is selected flashing with the Next key its value can be altered through use of the Down key Program Mode U...

Страница 6: ...ts are as required press the ENT key to confirm the changes the display will stop flashing IMPORTANT You must press the ENT key within 15 seconds of the last keypress when entering a new value otherwi...

Страница 7: ...e digits will flash use Next key to select each digit to be adjusted and adjust digit value using Down key When adjustment is complete press ENT key to exit Edit Mode digits will become static 2 To ad...

Страница 8: ...a parameter use the Down key to step through the parameters when the desired parameter description is shown in the upper display press the Next key to enter Edit Mode and to scroll through the availab...

Страница 9: ...medium speed 25 0ms low speed Control Inputs Remote Reset Terminal 5 edge sensitive Program Mode Terminal 6 level sensitive Input Voltage High 3 0V or open Low 2 0V Input Impedance 4 7k to V Input Re...

Страница 10: ...10 N O T E S...

Страница 11: ...11 N O T E S...

Страница 12: ...Neuhausen ADF Tel 49 71589003 0 Fax 49 71589003 32 In Brazil Veeder Root do Brasil Rua Ado Benatti No 92 Caixa Postal 8343 CEP 05037 010 S o Paulo Tel 55 118612155 Fax 55 118611982 1675 N Delany Road...

Отзывы: