TCP/IP Interface Module Installation
Connect a PC or Laptop to the TCP/IP Interface Module
9
3. Press the front panel MODE key to access the Setup Mode. Press the FUNCTION key to access
Communications Setup.
4. In Communications Setup, press STEP until you see Port Settings, then press ENTER to display the
message::
If necessary, press the TANK/SENSOR key until you see the message above, where X = the slot number in
which you installed the TCP/IP Interface Module, and Type = S-SAT.
For TLS-350/ProMax consoles only - if the TCP/IP module was installed in slot 4 of the
Comm Bay card cage, the displayed slot number (X) will be 5.
5. Depending on displayed board type (S-SAT) and the console’s installed software revision level, select the
Comm board setup parameters shown in Table 1 or Table 2 as applicable.
Connect a PC or Laptop to the TCP/IP Interface Module
There are two ways you can connect a PC to the module:
• Over a network (LAN, WAN), or
• Directly (requires a crossover cable)
Table 1. Comm Setup Selections - S-SAT board type & V15 - V20 console software
Comm Setup Parameter
Setting
Baud Rate
9600
Parity
NONE
Stop Bit
1 STOP
Data Length
8 DATA
RS-232 END OF MESSAGE
DISABLED
Table 2. Comm Setup Selections - S-SAT board type & V21 & later console software
Comm Setup Parameter
Setting
Baud Rate
9600
Parity
NONE
Stop Bit
1 STOP
Data Length
8 DATA
Code (security)
DISABLED
DTR NORMAL STATE
HIGH
RS-232 END OF MESSAGE
DISABLED
COMM BOARD: X (Type)
BAUD RATE: 1200