2.6
Diagnostics Menu
Within the Tachograph Programmer there are a number of additional functions provided which
carry out various self-test functions and which allow setting of various default values.
To gain access to the internal utilities, first ensure that the Tachograph Programmer is turned off.
Press and hold
the ENTER key and then turn on the unit by pressing the ON key. As the unit
turns on it will emit a beep as usual, but in this case will request a Pass code – type “8642” and
press “ENTER” – the Programmer will then enter the DIAGNOSTICS MENU.
2.6.1 Diagnostics Menu - Function Descriptions
Language Select
- The MKII Tachograph Programmer may be operated in a number of
different languages. The available languages are dependant on the
Tachograph Programmer type.
Set Time and Date
- This is used to set the time (24 hour clock) and date (ddMMyyyy format)
used by the Programmer.
Fixed Distance Length - This allows the Length of the Fixed Distance Track (used in Programmer
Fixed-Distance Tests) to be altered between 20 and 1000m (previously
this was fixed at 20m permanently).
Hardware Test
- This function is used in conjunction with an external test jig for
conformance testing.
It is for use by SE personnel only.
Keyboard Test
- This enables the user to check that the keyboard is fully functional by
pressing each key in turn.
Display Test
- This causes the unit to display a visual routine so that the user can check
that the display is functioning correctly.
ROM Test
- This function can be used to check the Programmer’s internal read-only
memory (ROM) and display the result.
Battery Detect
- This is used to check the Voltage of the Programmer’s internal battery
pack. If within tolerance, message “Battery OK!” should be displayed. If
not then the battery needs recharging.
Frequency Test
- Used during conformance testing to calibrate the accuracy of the clock
within the Tachograph Programmer.
This function is for use by SE
personnel only.
Set calib no.
- This enables a user to enter a default identification string for a particular
tachograph fitting station. Generally this is the identification issued by the
approvals authority.
Bench test type
- This allows the selection of the appropriate bench test for any given
country. Standard bench tests are pre-programmed for several countries;
selecting the Custom bench test option allows a user to define a different
test sequence. See Annex B for details of the Bench Tests available and
instructions for programming a custom bench test.