background image

 

XSTREAM 2.4 GHZ WIRELESS MODEM  

For use with VEEDER-ROOT EMR³ DATALINK 

INSTALLATION INSTRUCTIONS 

Manual 577013-894,  Rev. B 

 

 

 

  

  

Page 14 of 14 

 

Important Note  

MaxStream does not list the entire set of standards that must be met for each country. MaxStream 
customers assume full responsibility for learning and meeting the required guidelines for each 
country in their distribution market. For more information relating to European compliance of an 
OEM product incorporating the 24XStream modem, contact MaxStream, or refer to the following 
web sites:  

CEPT ERC 70-03E – Technical Requirements, European restrictions and general requirements: 
Available at www.ero.dk/  

R&TTE Directive – Equipment requirements, placement on market: Available at 

www.ero.dk/  

 
Notice 

 
Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, 
the implied warranties of merchantability and fitness for a particular purpose. 
 
Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in 
connection with the furnishing, performance, or use of this publication. 
 
Veeder-Root reserves the right to change system options or features, or the information contained in this 
publication. 
 
This publication contains proprietary information which is protected by copyright. All rights reserved. No 
part of this publication may be photocopied, reproduced, or translated to another language without the 
prior written consent of Veeder-Root. 
 

DAMAGE CLAIMS 

1. Thoroughly examine all components and units as soon as they are received. If damaged, write a 
complete and detailed description of the damage on the face of the freight bill. The carrier's agent 

must 

verify the inspection and sign the description. 
 
2. Immediately notify the delivering carrier of damage or loss. This notification may be given either in 
person or by telephone. Written confirmation must be mailed within 48 hours. Railroads and motor 
carriers are reluctant to make adjustments for damaged merchandise unless inspected and reported 
promptly. 
 
3. Risk of loss, or damage to merchandise remains with the buyer. It is the buyer's responsibility to file a 
claim with the carrier involved. 
 

RETURN SHIPPING 

For the parts return procedure, please follow the appropriate instructions in the "General Returned 
Goods Policy" and "Parts Return" section of the Veeder-Root EMR³

 

price list. 

 

©Veeder-Root 2017. All rights reserved. 

 

Содержание EMR3 XStream-PKG

Страница 1: ...e Program Disc The Program Disc includes the USB Drivers and the full Program Manual as a pdf file 0846000 035 Truck Kit with Keypad XStream 2 4 GHZ Europe and Other The Truck Kit with Keypad includes...

Страница 2: ...ample of Label on Side of Modem FOR XSTREAM 2 4 GHZ MODEMS XSTREAM TRUCK MODEM MOUNTING AND CONNECTION 1 The dip switches on the XStream modem should be set to 1 ON 2 OFF 3 OFF 4 OFF 5 OFF 6 OFF 2 Scr...

Страница 3: ...with VEEDER ROOT EMR DATALINK INSTALLATION INSTRUCTIONS Manual 577013 894 Rev B Page 3 of 14 4 Add the screw clips and screws to the head of the RS 232 cable plug into the connector and tighten the sc...

Страница 4: ...provides the communication to the wireless modem and also the modem power Modem power is provided from the 12 V OUT in the Interconnect Box Install the cord grip in the interconnect box and connect t...

Страница 5: ...e red light on the modem next to the RS 232 connector will be on Before leaving the vehicle go to the display and make sure the PORT 2 ASSIGN under SETUP SYSTEM ADDRESS is set to OBC Push the MODE but...

Страница 6: ...connector into the modem completely and attach the USB CABLE 3 Plug the power supply into a normal 110 volt outlet or with the proper non Americas Plug The three green signal lights on the modem will...

Страница 7: ...e Install from specific list or location Advanced option then select the Next button 3 Select the Search for best driver in these locations option and check the Search removable media CD ROM box 4 Sel...

Страница 8: ...OOT EMR DATALINK INSTALLATION INSTRUCTIONS Manual 577013 894 Rev B Page 8 of 14 Finding the communications port for using the USB Modem with the DataLink Program Start Control Panel Double Click on Sy...

Страница 9: ...TREAM 2 4 GHZ WIRELESS MODEM For use with VEEDER ROOT EMR DATALINK INSTALLATION INSTRUCTIONS Manual 577013 894 Rev B Page 9 of 14 Click on the Hardware Tab Device Manager Screen Click on Device Manage...

Страница 10: ...the MaxStream Modem have not been loaded Plug the MaxStream USB Modem into your computer and follow the Plug and Play instructions or got to Add Hardware on the Control Panel For use with the DataLink...

Страница 11: ...d gently removed from the housing 1 Remove the cover from the hole in the right side of the display head housing 2 Put the rubber gasket over the threads on the keypad outlet 3 Align the gasket and ke...

Страница 12: ...XSTREAM 2 4 GHZ WIRELESS MODEM For use with VEEDER ROOT EMR DATALINK INSTALLATION INSTRUCTIONS Manual 577013 894 Rev B Page 12 of 14 6 Connect the keypad wires per this diagram...

Страница 13: ...SE PRICE OF THE PRODUCT FOR ANY LOSS OF USE LOSS OF TIME INCONVENIENCE COMMERCIAL LOSS LOST PROFITS OR SAVINGS OR OTHER INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY...

Страница 14: ...ion Veeder Root reserves the right to change system options or features or the information contained in this publication This publication contains proprietary information which is protected by copyrig...

Отзывы: