OFF – the port is turned off;
Pr1 – Protocol VEDIA with uninterrupted weight transmission;
Prn – is not used.
After each change of the protocol, the scale is restarted.
- In the submenu, an operating mode for the backlights of the two LCD displays is
selected. Available working modes:
1.OFF – Backlight is turned off each time the readings for the weight is zero (battery saving mode);
2.On – Backlight is always on.
- In the submenu the user has access to the following service mode functions:
1. ADC – Test of the Analog-to-Digital Converter. The display shows direct readings of the
ADC;
2. t
o
C – Thermometer. The display shows themperature in degree Celsius;
3. Ver – Version. The display shows the current version of the scale software;
4. nCal – The display shows the number of the performed actions in service mode.
6. Operation with the rechargeable battery
The charging of the rechargeable battery is made with an adapter, bought together with the scale.
The adapter should be plug in DC 12V jack that is on the right side of the case. During the recharging
the scale can operate or can be switched off. The battery is fully recharged for approximately 8 hours.
The current voltage of the battery can be checked from menu 1.Bat of the scale. When “battery”
symbol is shown on the display, please recharge the battery as soon as possible. In reaching
impermissibly low voltages, the display turns off and the scale operation is blocked till the normal
values of the voltage are restored (plug in the adaptor).
7. Errors
Err1 – it is shown after passing the indication test when the load cell is deformed of
overloading or due to some reason the platform is heavier. The extra load should be removed.
If the error does not disappear turn to the closest service centre.
Err2 – when it is shown after passing the indication test it means that the load cell is
deformed backwards or the platform has is lightened. Place the pan on the scale or if it is on
its place turn to the closest service centre.
Err3 – after the initial zero- setting the weight of the platform is below the given limits.
Probably the pan has been removed during the operation or something is raising it.
Err4 – the scale is loaded with so extremely heavy load that it cannot be read by the
electronic block. If the scale is unloaded, turn to the nearest service.
Err5 – It is shown on the display with turning on the scale when data incorrectness in the
memory is detected.
“-HI-“ – overloading indication –a load over the maximum capacity is placed on the platform