Technical data 

 

Doc: 70-00-0588 V1.0, 20180928 

© Vector Controls GmbH, Switzerland 

Page 2 

Subject to alteration 

www.vectorcontrols.com 

 

Technical specifications 

Power Supply 

Operating Voltage 

24 V AC/DC ± 10 %, 50/60 Hz, Class 2 48VA max 

Power Consumption 

Max. 1.5 VA 

Electrical Connection 

Terminal Connectors,  

wire 0.34-2.5 mm

2

 (AWG 24…12)

 

Signal inputs 

Temperature Input 

 

Range 

0-50 °C (32-122 °F) 

Accuracy 

0.5 K 

Signal outputs 

Analog Outputs 
Output Signal 

Resolution 
Maximum Load 

AO1, AO2  
DC 0-10 V 

9.76 mV (10 bit) 
10 mA  

Environment 

Operation 
Climatic Conditions 

Temperature 

Humidity 

To IEC 721-3-3 
class 3 K5 

0-50 °C (32-122 °F) 

<95 % r.H. non-condensing 

Transport & Storage 
Climatic Conditions 

Temperature 

Humidity 

Mechanical Conditions 

To IEC 721-3-2 and IEC 721-3-1 
class 3 K3 and class 1 K3 

-25-70 °C (-13-158 °F) 

<95 % r.H. non-condensing 

class 2MT2 

Standards 

conform according to  
EMC Standard 

89/336/EEC 

EMEI Standard 73/23/EEC 

 
EN 61 000-6-1/ EN 61 000-6-3 

Product standards 
Automatic electrical controls for 

household and similar use 

Special requirement on 

temperature dependent controls 

 
EN 60 730 –1 

 

EN 60 730 – 2 – 9 

Degree of Protection 

IP30 to EN 60529 

Safety Class 

III (IEC 60536) 

 

 

General 

Housing material: 

Fire proof ABS plastic (UL94 class V-0) 

 

Dimensions (H x W x D) 

Front part: 60 x 60 x 8 mm (2.4” x 2.4” x 0.3”)  

Power case: ø 58 x 27 mm (ø 2.3” x 1.1”) 

 

Weight (including package) 

115 g (4.0 oz) 

Dimensions [mm] (inch) 

 

 

6

0

 (

2

.4

)

 

60 (2.4) 

27 (1.1)

 

8 (.3)

 

58 

(2

.3

)

 

Содержание TCT-MZ

Страница 1: ...plications Control of ventilation systems for comfort and industrial applications General description The TCT MZ is a microprocessor controlled precision positioner with real time clock and time sched...

Страница 2: ...0 C 32 122 F 95 r H non condensing Transport Storage Climatic Conditions Temperature Humidity Mechanical Conditions To IEC 721 3 2 and IEC 721 3 1 class 3 K3 and class 1 K3 25 70 C 13 158 F 95 r H non...

Страница 3: ...mmon U1 Analog output supply air 0 10 V DC U2 Analog output return air 0 10 V DC Mounting location On an easy accessible interior wall approx 1 5 m 4 5 above the floor in an area of average temperatur...

Страница 4: ...are memorized and do not need to be reentered Depending on UP03 the unit will remain switched off switch on automatically or return to the operation mode it was in before the power failure Deluxe ver...

Страница 5: ...schedules Press CLOCK key 2 sec Time schedule operation is enabled or disabled alternately Creating time schedules Step 1 Select a switching time Up to 8 Pr01 Pr08 Press CLOCK Key 2 sec SEL and curre...

Страница 6: ...ct a password using UP or DOWN buttons Select 009 in order to get access to the user parameters Press OPTION after selecting the correct password 3 Once logged in the parameter is displayed immediatel...

Страница 7: ...OFF 0V energy hold off 0 100 0 10V or 2 10V OFF 0 100 100 CP 12 Full supply mode Volume for return air OFF 0V energy hold off 0 100 0 10V or 2 10V OFF 0 100 OFF Signal limitation for VAV systems The m...

Отзывы: