background image

 

 
 

Page 1 of 8

 

GC31-IOM Rev. B     

07/19 

 

 

 

 

 

 

Enidine / Conoflow 

105 Commerce Way 
Westminster, SC  29693 
Tel:  (864) 647-9521 
Fax: (864) 647-7993 

 

 

 
 

INSTRUCTION AND MAINTENANCE MANUAL 

GC31 COMMANDAIRE POSITIONER

 

 

 

PRINCIPLE OF OPERATION 

 

The COMMANDAIRE Model GC31 positions the actuator by applying a sufficient air pressure in the load chamber to overcome the cushion load 
pressure, plus any external forces or load acting on the actuator stem.  An increase in air signal pressure acts on a diaphragm and moves the yoke to 
the right.  This closes an exhaust port and opens the supply valve.  Air flows through the supply valve into the load chamber and drives the piston 
downward, extending the actuator stem.  Piston movement extends the range spring,

 which in turn

, causes the bellcrank to rotate

 

counterclockwise.  

This rotation of the bellcrank exerts a force against the yoke pin and moves the yoke towards a balanced position.  A decrease in instrument air pressure 
reverses the procedure, closing the supply valve and opening the exhaust port.  This vents the pressure in the load chamber to atmosphere and allows 
the cushion load pressure to move the piston and retract the actuator stem. 

WARNING 

Conoflow products are designed and manufactured using 
materials and workmanship required to meet all applicable 
standards.  The use of these products should be confined to 
services specified and/or recommended in the Conoflow 
catalogs, instructions, or by Conoflow application engineers. 

 

To avoid personal injury or equipment damage resulting from 
misuse or misapplication of a product, it is necessary to select 
the proper materials of construction and pressure-temperature 
ratings which are consistent with performance requirements. 

Содержание GC31

Страница 1: ...lcrank to rotate counterclockwise This rotation of the bellcrank exerts a force against the yoke pin and moves the yoke towards a balanced position A decrease in instrument air pressure reverses the p...

Страница 2: ...at the factory for the proper range and spring rod 8A extension as shown on page 6 With the actuator stem in the fully retracted position and the spring rod nut 16 removed from the spring rod 8A thre...

Страница 3: ...or stem to retract when an air supply failure occurs The airlock system consists of a volume tank pressure vessel and a check valve that drives the cushion load regulator and lifts the actuator piston...

Страница 4: ...0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 9 10 4 2 2 3 4 2 3 5 TRAVEL IN INCHES FOR SPAN REQUIRED NOTE For travels greater than 10 254mm consult factory 3 4 6 12 24 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 R...

Страница 5: ...31 IOM Rev B 07 19 Notes 1 All connections are NPT unless otherwise noted 2 When ordering specify model range and stroke 3 For additional piping schematics see A50 48 4 Vent ports can be tapped NPT fo...

Страница 6: ...8 32 x 1 2 Long 6 G6900574 11 5 Spacer 2 G6026785 12 4 Self Tapping Screw 3 8 Long 3 G6900545 13 1 Gasket 1 G6001762 Item No Description Qty Req d Part No 14 Hex Head Capscrew 1 4 20 x 5 8 Long 6 G69...

Страница 7: ...entification and rapid handling of order 3 For body assembly order item G6026504 Consists of items 10 through 12 and items 15 through 25 4 For tapped exhaust use a G6026819 for item 9 b G6027155 for i...

Страница 8: ...Page 8 of 8 GC31 IOM Rev B 07 19 This Page Intentionally Left Blank...

Отзывы: