Страница 1: ...S MANUAL INCLUDES INSTRUCTIONS FOR 110 VOLT AC POWER INVERTER OPTION THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT BEFORE USE READ AND...
Страница 2: ...g 8 3 2 12 Volt DC Charging 8 3 3 110 120 Volt AC Charging Using VEC070 Automatic 1 5 Amp Battery Charger 9 3 4 Estimated Battery Life 9 4 OPERATING AS A PORTABLE POWER SUPPLY 4 1 Operating as a 12 Vo...
Страница 3: ...not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents...
Страница 4: ......
Страница 5: ...UNIT ON A FLAT STABLE SURFACE BE SURE TO KEEP ALL CLAMPS CORDS CLOTHING AND BODY PARTS AWAY FROM MOVING VEHICLE COMPONENTS 9 DO NOT WEAR VINYL CLOTHING WHEN JUMPSTARTING A VEHICLE FRICTION CAN CAUSE...
Страница 6: ...NOT ATTEMPT TO JUMPSTART A VEHICLE THAT DOES NOT HAVE A BATTERY INSTALLED 9 VEHICLES THAT HAVE ON BOARD COMPUTERIZED SYSTEMS MAY BE DAMAGED IF VEHICLE BATTERY IS JUMPSTARTED BEFORE JUMPSTARTING READ...
Страница 7: ...ycling contact your local authority for information THIS UNIT CONTAINS A MAINTENANCE FREE SEALED NON SPILLABLE LEAD ACID BATTERY WHICH MUST BE DISPOSED OF PROPERLY SOME STATES REQUIRE RECYCLING DISPOS...
Страница 8: ...C Power Supply NOTE ALL TIMES ARE APPROXIMATE AND BASED UPON FULLY CHARGED UNIT 4 3 Operation as a 110 Volt AC Power Supply Use with VEC040 50 Watt VEC023 175 Watt or VEC024 400 Watt Maxx Power Invert...
Страница 9: ...ng amps 1200 peak amps Solid state automatic operation and built in circuit protection Safe to use transport and store Includes non spillable maintenance free heavy duty 19 amp hour sealed battery Req...
Страница 10: ...AN ADDITIONAL HOUR USING THE DC METHOD OR 2 4 HOURS USING THE AC METHOD 3 FULLY RECHARGE UNIT AFTER EACH USE OR WHEN CHARGE STATUS INDICATOR SHOWS LOWER THAN 4 RED LED AND EVERY 2 MONTHS WHEN NOT IN...
Страница 11: ...he NEGATIVE BLACK DC Battery Clip to the BLACK NEGATIVE jumpstarter clamp 5 Connect the charger to an AC outlet or extension cord rated at 18 AWG or larger 6 Turn ON the Safety switch and observe the...
Страница 12: ...tlet 2 Plug the 12 volt DC cigarette type plug into the 12 volt DC receptacle on the unit 3 Charge this device for at least 14 16 hours or until the FULL indicator lights when Charge Status Button is...
Страница 13: ...e lighter This allows maximum portability and utility when the START IT is used in remote locations For maximum convenience the START IT can be recharged from any standard 110 120 volt AC or 12 volt D...
Страница 14: ...strain long hair before attempting jumpstart procedure WARNINGS 1 Vehicles that have on board computerized systems may be damaged if vehicle battery is jumpstarted Before jumpstarting this type of veh...
Страница 15: ...ve clamps disconnect the negative Black jumper cable first followed by the positive Red jumper cable and replace them in the built in storage holsters CAUTIONS 1 If vehicle fails to start leave vehicl...
Страница 16: ...VECTOR MANUFACTURING Ltd 4140 S W 28th Way Ft Lauderdale FL 33312...