Vector START-IT VEC021ST Скачать руководство пользователя страница 10

NOTE: The Start-It Jumpstart System is equipped with an audible Reverse

Polarity Alarm. This feature is only active when the Safety Switch is
turned OFF. After both battery clamp connections are made during
jump-start procedures, if you hear a buzzing sound, DO NOT TURN
ON THE SAFETY SWITCH. You must swap the clamp connections
before continuing. If the buzzer does not sound, it is safe to turn on
the Safety Switch and follow the Jumpstart procedure.

NOTE: The alarm requires at least two volts to operate, so in the rare

instance of a totally dead battery, the alarm may not sound if 
the polarity connection is reversed. This is very unlikely because
almost all dead batteries rarely go below four or five volts. Always
double-check your connections before turning on the Safety Switch.

IMPORTANT INFORMATION:

CAUTION

: READ INSTRUCTION MANUAL AND PRODUCT LABELING CAREFULLY, FOR COMPLETE 

INSTRUCTIONS, BEFORE USING THIS PRODUCT. FOLLOW RECOMMENDED WARNINGS, CAUTIONS, 
SAFETY PROCEDURES, AND MANUFACTURER GUIDELINES FOR YOUR VEHICLE’S BATTERY.

1.

IMPORTANT: ALTHOUGH THIS UNIT IS DELIVERED IN A PARTIALLY-CHARGED STATE—YOU
MUST FULLY CHARGE IT WITH THE SUPPLIED 110/120-VOLT AC CHARGER FOR A FULL 24
HOURS, BEFORE USING IT FOR THE FIRST TIME.

2.

IMPORTANT

: DO NOT OVERCHARGE UNIT, THIS WILL REDUCE BATTERY LIFE. CHARGE UNTIL GREEN

“CHARGED” INDICATOR IS LIT WHEN CHARGE STATUS BUTTON IS PRESSED. AFTER GREEN  “CHARGED”

INDICATOR LIGHT COMES ON WHEN CHARGE STATUS BUTTON IS PRESSED, UNIT CAN BE TOP-OFF

CHARGED FOR AN ADDITIONAL HOUR USING THE DC METHOD OR 2-4 HOURS USING THE AC

METHOD.

3.

FULLY RECHARGE UNIT AFTER EACH USE, OR WHEN CHARGE STATUS INDICATOR SHOWS LOWER THAN  

4 RED LED, AND EVERY 2 MONTHS WHEN NOT IN USE.

4.

ALWAYS RECHARGE IN A DRY, WELL-VENTILATED AREA, AWAY FROM WATER.

5.

WHEN CHARGING IN ANY WET OR DAMP AREA FROM A 110/120-VOLT ELECTRICAL 
OUTLET, MAKE SURE THAT THE OUTLET USED IS PROTECTED BY A GROUND FAULT CIRCUIT
INTERRUPT (GFCI) CIRCUIT.

6.

WHEN CHARGING THE UNIT NEAR WATER (POOL, DOCKSIDE, BEACH, ETC.) 

DO NOT ALLOW THE 

ELECTRICAL CORDS AND OUTLETS TO GET WET OR COME NEAR WATER — ELECTRICAL 
SHOCK COULD RESULT!

7.

USE ONLY THE SUPPLIED CORDS FOR RECHARGING/OPERATING THIS UNIT.

8.

IT IS RECOMMENDED THAT UNIT BE KEPT UPRIGHT DURING USE AND WHEN RECHARGING.

9.

WHEN NOT IN USE, STORE UNIT WITH ON/OFF SWITCH TURNED OFF.

SAFETY WARNINGS:

1.

THERE IS A RISK OF EXPLOSIVE GASES BEING RELEASED WHEN BATTERIES ARE IMPROPERLY CHARGED

OR DISCHARGED. FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE PROPERTY DAMAGE, EXPLOSIVE

HAZARD AND/OR PERSONAL INJURY.

2.

ALWAYS USE PROTECTIVE EYEWEAR WHEN USING THIS PRODUCT: CONTACT WITH BAT-
TERY ACID MAY CAUSE BLINDNESS AND/OR SEVERE BURNS.

3.

KEEP OUT OF REACH OF CHILDREN!!

4.

ALWAYS STORE BATTERY CLAMPS IN BUILT-IN HOLSTERS WHEN NOT IN USE. NEVER TOUCH BATTERY

CLAMPS TOGETHER – THIS CAN CAUSE DANGEROUS SPARKS, POWER ARCING, AND/OR EXPLOSION.

FIRST AID:

1.

SKIN

:IF BATTERY ACID COMES IN CONTACT WITH SKIN, RINSE IMMEDIATELY WITH WATER, THEN WASH

THOROUGHLY WITH SOAP AND WATER. IF REDNESS, PAIN, OR IRRITATION OCCURS, SEEK 

IMMEDIATE MEDICAL ATTENTION.

2.

EYES

: IF BATTERY ACID COMES IN CONTACT WITH EYES, FLUSH EYES IMMEDIATELY – FOR MINIMUM 

OF 15 MINUTES — SEEK IMMEDIATE MEDICAL ATTENTION.

4

Содержание START-IT VEC021ST

Страница 1: ...S MANUAL INCLUDES INSTRUCTIONS FOR 110 VOLT AC POWER INVERTER OPTION THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT BEFORE USE READ AND...

Страница 2: ...g 8 3 2 12 Volt DC Charging 8 3 3 110 120 Volt AC Charging Using VEC070 Automatic 1 5 Amp Battery Charger 9 3 4 Estimated Battery Life 9 4 OPERATING AS A PORTABLE POWER SUPPLY 4 1 Operating as a 12 Vo...

Страница 3: ...not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents...

Страница 4: ......

Страница 5: ...UNIT ON A FLAT STABLE SURFACE BE SURE TO KEEP ALL CLAMPS CORDS CLOTHING AND BODY PARTS AWAY FROM MOVING VEHICLE COMPONENTS 9 DO NOT WEAR VINYL CLOTHING WHEN JUMPSTARTING A VEHICLE FRICTION CAN CAUSE...

Страница 6: ...NOT ATTEMPT TO JUMPSTART A VEHICLE THAT DOES NOT HAVE A BATTERY INSTALLED 9 VEHICLES THAT HAVE ON BOARD COMPUTERIZED SYSTEMS MAY BE DAMAGED IF VEHICLE BATTERY IS JUMPSTARTED BEFORE JUMPSTARTING READ...

Страница 7: ...ycling contact your local authority for information THIS UNIT CONTAINS A MAINTENANCE FREE SEALED NON SPILLABLE LEAD ACID BATTERY WHICH MUST BE DISPOSED OF PROPERLY SOME STATES REQUIRE RECYCLING DISPOS...

Страница 8: ...C Power Supply NOTE ALL TIMES ARE APPROXIMATE AND BASED UPON FULLY CHARGED UNIT 4 3 Operation as a 110 Volt AC Power Supply Use with VEC040 50 Watt VEC023 175 Watt or VEC024 400 Watt Maxx Power Invert...

Страница 9: ...ng amps 1200 peak amps Solid state automatic operation and built in circuit protection Safe to use transport and store Includes non spillable maintenance free heavy duty 19 amp hour sealed battery Req...

Страница 10: ...AN ADDITIONAL HOUR USING THE DC METHOD OR 2 4 HOURS USING THE AC METHOD 3 FULLY RECHARGE UNIT AFTER EACH USE OR WHEN CHARGE STATUS INDICATOR SHOWS LOWER THAN 4 RED LED AND EVERY 2 MONTHS WHEN NOT IN...

Страница 11: ...he NEGATIVE BLACK DC Battery Clip to the BLACK NEGATIVE jumpstarter clamp 5 Connect the charger to an AC outlet or extension cord rated at 18 AWG or larger 6 Turn ON the Safety switch and observe the...

Страница 12: ...tlet 2 Plug the 12 volt DC cigarette type plug into the 12 volt DC receptacle on the unit 3 Charge this device for at least 14 16 hours or until the FULL indicator lights when Charge Status Button is...

Страница 13: ...e lighter This allows maximum portability and utility when the START IT is used in remote locations For maximum convenience the START IT can be recharged from any standard 110 120 volt AC or 12 volt D...

Страница 14: ...strain long hair before attempting jumpstart procedure WARNINGS 1 Vehicles that have on board computerized systems may be damaged if vehicle battery is jumpstarted Before jumpstarting this type of veh...

Страница 15: ...ve clamps disconnect the negative Black jumper cable first followed by the positive Red jumper cable and replace them in the built in storage holsters CAUTIONS 1 If vehicle fails to start leave vehicl...

Страница 16: ...VECTOR MANUFACTURING Ltd 4140 S W 28th Way Ft Lauderdale FL 33312...

Отзывы: