background image

1 1

OPERATING TIPS

The 

Power Force 50™

should only be operated in locations that meet the

following criteria:

DRY -

Do not allow water or other liquids to come into contact with the inverter.

COOL -

Ambient air temperature should be between  -20°C and 40°C - ideally

between 15°C and 25°C (60 - 80°F). Do not place the inverter on or near a
heating vent or any piece of equipment which is generating heat above room
temperature. Keep the inverter away from direct sunlight, if at all possible.

VENTILATED -

Keep the area surrounding the 

Power Force 50™

clear to ensure

free air circulation around the unit. Do not place items on or over the inverter
during operation. The unit will shut down if the internal temperature exceeds 90°C.
Restart the unit once it cools down sufficiently.

SAFE -

Do not use the 

Power Force 50™

near flammable materials or in any

locations that may accumulate flammable fumes or gases.

Rated Versus Actual Current Draw of Equipment

Most electrical tools, appliances, electronic devices and audio/visual equipment
have labels that indicate the power consumption in amps or watts. Be sure that the
power consumption of the item to be operated is below 50 watts. If the power
consumption is rated in amps, simply multiply by the AC volts (110) to determine
the wattage.

Resistive loads are the easiest for the 

Power Force 50™

to run; however, it will not

run larger resistive loads (such as electric stoves and heaters) which require far more
wattage than the 

Power Force 50™

can deliver on a continuous basis. Inductive

loads (such as TVs and stereos) require more current to operate than do resistive
loads of the same wattage rating. Induction motors, as well as some TVs, may
require 2 to 6 times their wattage rating to start up. The most demanding in this
category are those that start under load, such as compressors and pumps. Testing
is the only definitive way to determine whether a specific load can be started and
how long it can run. For safety reasons, the unit will simply shut down if it is
overloaded. To restart the unit after a shutdown due to overloading, momentarily
turn off the power to the unit.

Note: The Power Force 50™ will not operate appliances and equipment that

generate heat, such as hair dryers, microwave ovens, and toasters.

Содержание Pocket Generator VEC018-AC

Страница 1: ...WNER S MANUAL WARRANTY INFORMATION POCKET GENERATOR PORTABLE CORDLESS RECHARGEABLE POWER SUPPLY 1 1 0 VOLT AC 1 2 VOLT DC PATENT PENDING THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARD ING SAFETY OP...

Страница 2: ...nent utility power sources are not available It is ideal for use with Vector 12 volt DC cordless portable rechargeable products The Pocket Generator can be used to Operate 12 volt DC Fans inflators fl...

Страница 3: ...t note will not recharge a completely dead vehicle battery Use as a Memory Saver protects pre set electronic settings for seats radio A C etc if battery power is to be disconnected for repair maintena...

Страница 4: ...take 12 15 hours approx 2 Insert the cigarette lighter plug at the end of the AC charger cord into the matching 12 volt receptacle on the side of the Pocket Generator 3 Plug the charger into any stand...

Страница 5: ...Estimated run times 4 12 VOLT DC APPLIANCE APPROX RUNNING TIME CELL PHONE FLORESCENT LIGHT 6 12 HOURS RADIO FAN DEPTH FINDER 5 HOURS CAMCORDER VCR SPOTLIGHT 2 5 HOURS ELECTRIC TOOLS BILGE PUMP 1 HOUR...

Страница 6: ...e device and operate as usual Run time depends upon the amperage draw of the device see charts 5 Green power ON light next to switch will be lit 12 volt DC Operation WARNINGS When using the Pocket Gen...

Страница 7: ...sure that the ON OFF switch on the inverter is in the OFF position before using unit as Memory Saver Failure to do so may cause damage to the inverter and will void manufacturer s warranty When the ve...

Страница 8: ...ps peak surge capacity Weight 4 60lbs Height 6 25 Depth 4 00 Width 7 50 Power Force 50 Inverter WARNING Do not attempt to remove the inverter from the unit for any reason it is hard wired into the uni...

Страница 9: ...50 INVERTER WORKS The Power Force 50 inverter is an electronic device that converts low voltage DC direct current electricity from a battery to standard 110 volt AC alternating current household powe...

Страница 10: ...e output of the Power Force 50 For accurate measurement of the output voltage of this unit use a true RMS reading voltmeter such as a Fluke 87 Fluke 8080A Beckman 4410 or Triplett 4200 POWER SOURCE RE...

Страница 11: ...device monitor its temperature for the initial ten minutes of use to determine whether it emits excessive heat If excessive heat is detected it is a good indication that the device should not be used...

Страница 12: ...ve labels that indicate the power consumption in amps or watts Be sure that the power consumption of the item to be operated is below 50 watts If the power consumption is rated in amps simply multiply...

Страница 13: ...tially hazardous conditions Low Battery Voltage this condition is not harmful to the inverter but could dam age the power source so the inverter automatically shuts down when input voltage drops to 10...

Страница 14: ...vides an adequate snow free signal and that high quality shielded antennae cable is used Common Power Output Problems Problem Lack Of Power Output Possible Causes Recommendations Inverter not adequate...

Страница 15: ...wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight Damage caused by misuse abuse neglect alterations repairs by unauthorized persons or fail...

Страница 16: ...chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse ab...

Отзывы: