CAUTION:

DO NOT CONNECT TO AC DISTRIBUTION WIRING: 

The 

Power Force 50™

is engineered to be connected directly to standard

electrical and electronic equipment in the manner described above. Do not
connect the Power Inverter to household or RV AC distribution wiring. Do not
connect the Power Inverter to any AC load circuit in which the neutral conductor is
connected to ground (earth) or to the negative of the DC (battery) source. 

CAUTION:

RECHARGEABLE APPLIANCES

Certain rechargeable devices are designed to be recharged by plugging them
directly into an AC receptacle. These devices may damage the 

Power Force 50™

.

When first using a rechargeable device, monitor its temperature for the initial ten
minutes of use to determine whether it emits excessive heat. If excessive heat is
detected, it is a good indication that the device should not be used with this
inverter. This problem does not occur with the majority of battery-operated
equipment.  Most of these devices use a separate charger or transformer that is
plugged into an AC receptacle. The 

Power Force 50™

is capable of running most

chargers and transformers.

FUSE REPLACEMENT

If the 

Power Force 50™

is overloaded, replace the main fuse as follows:

1. Open the top flap of the 

Pocket Generator™

, carrying case. The main fuse

holder’s screw-on/off cap will immediately be visible.

2. Unscrew the fuse holder cap and remove the fuse.
3. Replace with a new 10-amp fuse, if needed.
4. Screw fuse holder cap back on.
5. Close case securely.

1

2

3

4

Fig. 3.

Содержание Pocket Generator VEC018-AC

Страница 1: ...WNER S MANUAL WARRANTY INFORMATION POCKET GENERATOR PORTABLE CORDLESS RECHARGEABLE POWER SUPPLY 1 1 0 VOLT AC 1 2 VOLT DC PATENT PENDING THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARD ING SAFETY OP...

Страница 2: ...nent utility power sources are not available It is ideal for use with Vector 12 volt DC cordless portable rechargeable products The Pocket Generator can be used to Operate 12 volt DC Fans inflators fl...

Страница 3: ...t note will not recharge a completely dead vehicle battery Use as a Memory Saver protects pre set electronic settings for seats radio A C etc if battery power is to be disconnected for repair maintena...

Страница 4: ...take 12 15 hours approx 2 Insert the cigarette lighter plug at the end of the AC charger cord into the matching 12 volt receptacle on the side of the Pocket Generator 3 Plug the charger into any stand...

Страница 5: ...Estimated run times 4 12 VOLT DC APPLIANCE APPROX RUNNING TIME CELL PHONE FLORESCENT LIGHT 6 12 HOURS RADIO FAN DEPTH FINDER 5 HOURS CAMCORDER VCR SPOTLIGHT 2 5 HOURS ELECTRIC TOOLS BILGE PUMP 1 HOUR...

Страница 6: ...e device and operate as usual Run time depends upon the amperage draw of the device see charts 5 Green power ON light next to switch will be lit 12 volt DC Operation WARNINGS When using the Pocket Gen...

Страница 7: ...sure that the ON OFF switch on the inverter is in the OFF position before using unit as Memory Saver Failure to do so may cause damage to the inverter and will void manufacturer s warranty When the ve...

Страница 8: ...ps peak surge capacity Weight 4 60lbs Height 6 25 Depth 4 00 Width 7 50 Power Force 50 Inverter WARNING Do not attempt to remove the inverter from the unit for any reason it is hard wired into the uni...

Страница 9: ...50 INVERTER WORKS The Power Force 50 inverter is an electronic device that converts low voltage DC direct current electricity from a battery to standard 110 volt AC alternating current household powe...

Страница 10: ...e output of the Power Force 50 For accurate measurement of the output voltage of this unit use a true RMS reading voltmeter such as a Fluke 87 Fluke 8080A Beckman 4410 or Triplett 4200 POWER SOURCE RE...

Страница 11: ...device monitor its temperature for the initial ten minutes of use to determine whether it emits excessive heat If excessive heat is detected it is a good indication that the device should not be used...

Страница 12: ...ve labels that indicate the power consumption in amps or watts Be sure that the power consumption of the item to be operated is below 50 watts If the power consumption is rated in amps simply multiply...

Страница 13: ...tially hazardous conditions Low Battery Voltage this condition is not harmful to the inverter but could dam age the power source so the inverter automatically shuts down when input voltage drops to 10...

Страница 14: ...vides an adequate snow free signal and that high quality shielded antennae cable is used Common Power Output Problems Problem Lack Of Power Output Possible Causes Recommendations Inverter not adequate...

Страница 15: ...wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight Damage caused by misuse abuse neglect alterations repairs by unauthorized persons or fail...

Страница 16: ...chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse ab...

Отзывы: