background image

IMPORTANT SAFETY INFORMATION

To  ensure reliable service, your power inverter must be installed and used 
properly. Please read the installation and operating instructions thoroughly prior
to installation and use. Pay particular attention to the WARNING and CAUTION
statements in this manual. The CAUTION statements advise against certain 
conditions and practices that may result in damage to your inverter. The WARNING
statements identify conditions or practices that may result in personal injury.

READ ALL INSTRUCTIONS BEFORE USING THIS POWER INVERTER

WARNINGS

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION OR INJURY:

Do not

connect to AC distribution wiring

Remove appliance plug from outlet strip or turn off inverter before
working on the appliance

DO NOT

place inverters in an area, room or compartment where

explosive or flammable fumes might be present

Using power strips, with switches and circuit breakers, only interrupt 
power to the “hot” receptacle terminals. The  “neutral” terminals remain 
powered with respect to the “ground” terminals

Always unplug appliances when servicing

This is not a toy - 

keep away from children

CAUTIONS

NO USER-SERVICEABLE COMPONENTS INSIDE; 
OPENING UNIT WILL VOID WARRANTY; TO SERVICE INVERTERS 
CONTACT SERVICE DEPARTMENT AT (866) 584-5504

Do not

install in engine compartment - install in a well ventilated area

Do not

use with positive ground electrical systems (the majority of

modern automobiles, RVs, trucks and boats are negative ground)

Reverse polarity connection will result in a blown fuse, may cause
permanent damage to the inverter and will void the warranty

This inverter will not operate appliances or equipment that exceed 
inverters maximum rating

Grounding the Neutral will cause the inverter to shut down

Do not

operate this inverter if it is wet

Not approved for use with medical equipment

IMPORTANT CABLE INFORMATION

Substantial power loss and reduced battery operating time results when inverters
are installed with cables that are not able to supply full power. Low 
battery power can result from cables that are either excessively long or an 
insufficient gauge. The installer/operator should be aware of all installation
requirements to maintain secure, electrical connections. Cable insulation and
ampacity must be the appropriate type for the environment. To purchase a prepared
cable and fuse set, 

contact Technical Support at (954) 584-4446 or 

toll-free (866) 584-5504.

Содержание MAXX SST VEC049C

Страница 1: ...NG SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT TO AVOID POSSIBLE INJURY OR PROPERTY DAMAGE PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS PRODUCT MAXX SST COMPACT POWER I...

Страница 2: ...p away from children CAUTIONS NO USER SERVICEABLE COMPONENTS INSIDE OPENING UNIT WILL VOID WARRANTY TO SERVICE INVERTERS CONTACT SERVICE DEPARTMENT AT 866 584 5504 Do not install in engine compartment...

Страница 3: ...Size 11 4 3 Battery Operating Time 11 12 4 4 Protective Features 12 5 0 INSTALLATION 13 5 1 Input Power Requirements 13 5 2 Operating Environment 13 14 5 3 Installation Sequence 14 5 4 Quick Operation...

Страница 4: ...covers to allow large motorized loads to start This eliminates almost all shutdowns from momentary overloads 3 This power inverter also incorporates a new cooling technology The new design cools the p...

Страница 5: ...w voltage audible alarm and reset sounds at 10 6 volts input Low voltage shutdown and automatic reset activates at 10 0VDC High input voltage shutdown activates at above 15 5VDC and automatic reset WA...

Страница 6: ...r cordless power tools if the charger carries a warning that dangerous voltages are present at the battery terminals Some fluorescent lamps may not operate properly with this type of inverter If the b...

Страница 7: ...y floats on the DC from the charger not really supplying power or being charged When out side AC fails the inverter continues to power the appliances for the life of the useful charge of the battery b...

Страница 8: ...MOSFETS This stage functions as a high power bipolar switch alternately applying opposite polarity to the AC out let HOT and NEUTRAL terminals Figure 4 Simplified Diagram Some Models only include vol...

Страница 9: ...verter avoid exceeding the watt rating of this unit If the power consumption of the tool or device is rated in amps multiply the amps by 110 120 VAC to determine the wattage For instance a power tool...

Страница 10: ...h in specifications for this power inverter If a motor refuses to start observe the battery voltage using a DC voltmeter while trying to start the motor If the battery voltmeter drops below 11 volts w...

Страница 11: ...f energy use the total running time and the average power consumption To get an estimate of the current in amps that the battery must be capable of delivering divide the load consumption power in watt...

Страница 12: ...ssive voltage drop between the battery power source and the inverter NOTE It is normal for the alarm to sound when the inverter is being connected to or disconnected from a 12VDC power source This doe...

Страница 13: ...Figure 7 Battery Wiring NOTE Vector Manufacturing recommends that for typical heavy duty uses a specified or equivalent main buss fuse See Page 18 be added as close as possible to the power source ba...

Страница 14: ...to use the inverter with any 12VDC power source that uses a positive ground Most vehicles boats and aircraft use negative ground systems Never connect the ground wire from the inverter to the DC negat...

Страница 15: ...manent installation or continue to use the inverter with low wattage appliances If the lamp does not light or does not work correctly A Check all connections and tighten any loose connections B Ensure...

Страница 16: ...r Contact Vector Manufacturing for any further installation information or questions You can purchase fuses fuse holders specific cable or cable battery connectors from your local electrical supplier...

Страница 17: ...erminal of the heavy duty fuse holder 15 Connect the other conductor of the heavy duty fuse holder to the positive battery terminal 16 Connect an insulated wire at least 12 AWG between the chassis gro...

Страница 18: ...Cable Gauge 6 FT 3 3 2 1 0 2 0 Proper Cable Gauge 10 FT 1 1 0 2 0 3 0 3 0 ANL Fuse Rating 200 250 300 500 500 Weight 4 6 lbs 2 08 kg 5 75 lbs 2 6 kg 8 4 lbs 3 81 kg 11 lbs 5 0 kg 11 lbs 5 0 kg Length...

Страница 19: ...elded without the inverter operating The problem may not be with the inverter However in some cases some interference may be visible particularly with weak TV signals Try the following corrective meas...

Страница 20: ...ed power tool Purely inductive load Make the load not purely does not operate at inductive Operate an correct speed incandescent lamp at same time as motor Television radio Snow in picture buzz Keep i...

Страница 21: ...r is responsible for the shipping charges on all returned items During the warranty period Vector Manufacturing Ltd will be responsible for the return shipping charges LIMITATIONS This warranty does n...