The inverter can be operated in any position, however, if it is to be
mounted on a wall, mount it horizontally so that indicators, switches,
outlets and terminal blocks located on the front panel are visible and 
accessible. If inverter is to be installed in a moving vehicle, Vector strongly
recommends that the inverter be shock-mounted either on the floor (in a
clear, safe area) or on a secure flat surface. Look for a convenient place
to mount inverter and the fuse holder. Take the length of cable and do a
trial routing of the cable. Don’t do any cutting at this time. Take a look at

FIGURE 7

. Measure the cable path and ensure that either the positive cable

run to the battery or negative cable run to the battery does not exceed 4
feet. Using #4 AWG reposition the inverter and fuse holder if necessary.
Remember and observe the other environmental requirements described
earlier.
After you have selected an appropriate location for the inverter and fuse
block, proceed with the actual installation of the inverter.
Contact Vector

Manufacturing for any further installation information or

questions. You can purchase fuses, fuse holders, #4 AWG cable or cable
battery connectors from your local electrical supplier or call Vector
Technical Support at (954) 584-4446 Ext. 119 for advice.

Common unattended applications for the UPS (floating battery) configura-
tions are for powering: sump pumps, safety lighting, communications
equipment, burglar alarm systems and computer systems.

3.0  THEORY OF OPERATION

MAXX SST™ inverters change 12 VDC into 110 VAC (110 VAC RMS), elec-
trical power. This is accomplished in two steps. See FIGURE 4.
The first stage raises the 12 VDC input to 145 VDC. The advanced
design of the DC-to-DC first stage uses modern high-frequency conversion 
techniques that replace bulky and heavy transformers found in older, less
technologically-advanced inverters. The output stage changes the 145-VDC
to 110 VAC. This solid-state circuitry ensures excellent overload protection
and the ability to operate reactive loads such as those found in inductive
motors and most fluorescent lamps. The inverter’s output stage uses multiple
banks of metal-oxide semiconductor field-effect transistors (MOSFETS). This
stage functions as a high-power bipolar switch, alternately applying oppo-
site polarity to the AC outlet HOT and NEUTRAL terminals.

Figure 4

Simplified Diagram

• Some Models only include volt, Amp and over temp indicators.

Neutral

100 AMP

TERMINAL

BLOCK

DC to DC

CONVERTER

INTERNAL WARNINGS &

PROTECTION CIRCUITS

VOLT, AMP METERS*

OVER TEMP & 

VOLT INDICATORS

ON/OFF

SWITCH

#4 AWG

WIRE

#4 AWG

WIRE

#4 AWG

WIRE

200

AMP

FUSE

Hot

145 VDO

Ground

VEC049

12 VOLT DC

INPUT FROM

BATTERY

THREE

OUTLETS

MOSFET

BIPOLAR

SWITCH

BANKS

+

+

NOTE: Cables, Fuse and
Battery Are Supplied By User

6

17

Содержание MAXX SST 1000

Страница 1: ...ETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT TO AVOID POSSIBLE INJURY OR PROPERTY DAMAGE PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS PRODUCT MAXX SST TM 1000 POWER INVERTE...

Страница 2: ...is not a toy keep away from children CAUTIONS NO USER SERVICEABLE COMPONENTS INSIDE OPENING UNIT WILL VOID WARRANTY Do not use with positive ground electrical systems the majority of modern automobil...

Страница 3: ...packaging in case you need to ship the unit When returning a product include your name address phone number dated sales receipt or copy and a description of the reason for return and product serial n...

Страница 4: ...fan only operates when the inverter s load requires it to operate It shuts off when cooling is not required 9 0 MAINTENANCE The inverters require minimal maintenance However for optimum perform ance...

Страница 5: ...l times If appliance does not start then appliance will not work with inverter Motorized power tool Purely inductive load Make the load not purely does not operate at inductive Operate an correct spee...

Страница 6: ...ude a high surge capability up to 2 000 watts which is required to start heavy loads such as motors and other inductive devices 8 0 TROUBLESHOOTING 8 1 COMMON PROBLEMS POWER TOOLS AND MICROWAVE OVENS...

Страница 7: ...liances into the inverter receptacles to directly recharge their nickel cadmium batteries Always use the recharger provided with that appliance DO NOT plug in battery chargers for cordless power tools...

Страница 8: ...he inverter should be as shown in FIGURE 7 Be sure to remove terminal cover and terminal nuts before starting permanent installation Inverter DC cables and fuse installation is as follows 1 Using tool...

Страница 9: ...n unattended applications for the UPS floating battery configura tions are for powering sump pumps safety lighting communications equipment burglar alarm systems and computer systems 3 0 THEORY OF OPE...

Страница 10: ...ctly A Check all connections and tighten any loose connections B Ensure that the source battery has adequate charge C If steps A through B do not correct the problem contact Vector Customer Service De...

Страница 11: ...d terminal nuts 2 Identify the Positive and negative terminals on the 12 volt DC battery and identify the positive and negative terminals on the inverter 4 0 OPERATION NOTE Ensure that the total conti...

Страница 12: ...harged If the connections are good and the battery is charged but the voltage still drops below 11 volts you may need to use a larger battery or battery combination 5 2 OPERATING ENVIRONMENT WARNINGS...

Страница 13: ...nput voltage drops below 10 5 VDC This built in feature protects the battery from being completely discharged The inverter will also shut down if the input voltage exceeds 15 volts This protects the i...

Страница 14: ...the number of amp hours you expect to use should be less than 50 of the battery s rated capacity 100 100 1000 1000 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 900 900 800 800 700 700 600 60...

Отзывы: