Extending Operating Time

Longer operating time can be realized by connecting ElectroMate to an

external battery. The external battery will combine the Ampere Hour ratings

of connected batteries. If your original configuration contains an 80 ampere

hour rated battery, connecting another similar battery will provide 160

ampere hours of capacity. This at least doubles the run time of your unit

before the batteries must be recharged.  The user should be aware that with

two similar batteries connected,  (one inside and one external) the charger

will take twice as long to recharge as with a single battery. There are two

methods to connect to an external battery: One is to use the Jumper cables;

the other way is to direct wire to the high current posts. Use the jumper cables

for extending run times of lighter temporary loads. Use the direct wiring method

for extended and more permanent higher power loads.

WARNINGS:

Never use the jumper cables to connect to a battery that is not stationary

– vibration can shake loose the cable clamps. A moving vehicle or boat

can shake loose connections. Never operate ElectroMate or an external

battery without securing them first. Cover any battery terminals.

Vector Manufacturing has #2 AWG cable sets that will ease connection to

an external battery. These are equipped with a fuse, fuse holder and ring

terminals on the cable ends. The cables are easily connected between the

external battery and the high current posts.  The only cautions are that the

high current post connection polarities must agree with the battery polarities.

The red cable must connect the red cap post and Pos or (+) battery terminal.

The black cable must connect the black cap post and Neg or (-) battery

terminal. Make sure all connections are tight. If you require a cable set,

contact Vector Technical Support at 866-584-5504.

Appendix A – Battery Installation Con’t

FIGURE A1

FIGURE A2

NEGATIVE

POSITIVE

PHILLIP SCREWS

POST COVERS

Содержание ElectroMate VEC095

Страница 1: ...AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 110 Volt AC 12 Volt DC Portable Power Supply VEC095 Electronic Gen...

Страница 2: ...le battery is jump started Before jump starting this type of vehicle read the vehicle s owner s manual to confirm that external starting assistance is advised 11 Excessive engine cranking can damage t...

Страница 3: ...Tips 12 5 7 Troubleshooting the Inverter 12 6 COMPRESSOR TIRE INFLATOR 12 6 1 Compressor Use 13 6 2 Compressor Safety Information 13 6 3 Inflation of Tire or Products with a Valve Stem 13 6 4 Typical...

Страница 4: ...ccessories This ElectroMate model is modular in design and can be considered as several interconnected components The major components are Battery Power Inverter Automatic Battery Charger Tire Compres...

Страница 5: ...I outlets can connect to any two or three pin North American standard appliance plugs ElectroMate is also ideal to power 12 Volt DC cordless portable appliances with a combined current rating up to 30...

Страница 6: ...rage Hatch and must be removed from the Storage Hatch for use The VEC077EM is a high frequency three stage charger that can either be permanently connected to ElectroMate or connected to a battery cla...

Страница 7: ...Battery Status Button Polarity Correct LED indicates when it s safe to turn on the Safety Switch Audible alarm sounds when polarity is incorrect Visual LED Alarm indicates Reverse Polarity Adjustable...

Страница 8: ...start Procedure 1 Make sure the ElectroMate Safety Switch is turned OFF enabling the reverse polarity alarms and correct polarity indicator 2 Turn Off ignition and all accessories radio A C lights et...

Страница 9: ...FCI dual outlets 110 Volt 60 Hz AC alternating current household power It s DC source is the installed 12 Volt battery Safety features include an audible low battery alarm and automatic shutdown to pr...

Страница 10: ...ied sine wave produced by the Power Inverter has an RMS root mean square voltage of 110 which is the same as standard household power Most AC voltmeters both digital and analog are calibrated for RMS...

Страница 11: ...itor its temperature for the initial ten minutes of use to determine whether it becomes warmer than usual If excessive heat is generated it is a good indication that the device should not be used with...

Страница 12: ...those that start under load such as compressors and pumps Testing is the only definitive way to determine whether a specific load can be started and how long it can run The unit will simply shut down...

Страница 13: ...re with the pressure gauge Never leave compressor unattended while in use Allow unit to cool after 10 minutes of continuous operation 6 3 Inflation of tire or products with a valve stem 1 Place connec...

Страница 14: ...ocation NOTE The lamp may be used with any 12 Volt DC source vehicle accessory socket that can supply at least one ampere This allows great flexibility in positioning the lamp during tire inflation an...

Страница 15: ...STORAGE HATCH IT WILL OVERHEAT AND SHUT DOWN POSSIBLE DAMAGE TO THE CHARGER MAY RESULT As recharge progresses the battery level LEDs will light one by one Charge the ElectroMate until the Battery Sta...

Страница 16: ...ry compartment cover Periodically the cables and connectors should be inspected for dam age corrosion dust and dirt If surfaces are dirty they can be wiped clean with a cloth moistened with water and...

Страница 17: ...artment Lift the two cables out of the way so they are not down inside the battery compartment Carefully lower the battery into the battery compartment The terminals on the battery can be one of sever...

Страница 18: ...extended and more permanent higher power loads WARNINGS Never use the jumper cables to connect to a battery that is not stationary vibration can shake loose the cable clamps A moving vehicle or boat c...

Страница 19: ...er Green LED lit battery charged and no alarms sound Battery is charged but Loose battery connections Clean all contacts tighten won t handle large loads the post connectors and battery terminals Fluo...