background image

5

Note:

The only time the selected charge rate does not display at the full selected rate
is when the battery is nearly full and charging at either step two or three. The
display will be showing a reduced charge rate. To return to 2A, press the
2/20/50 AMP button. When the battery is fully charged, the charging complete
and “FUL” is displayed on the Digital Display.

WARNING

If Digital Display shows “F02” and the Fault indicator lights, the
connection to the battery terminals is bad. Follow the steps outlined in
“Important Safety Instructions” at the front of this manual to
disconnect, clean battery terminals, then reconnect.
If Rev. Polarity indicator also lights, the Red (POSITIVE) and Black
(NEGATIVE) clamps are incorrectly connected to battery terminals.
Follow the steps outlined in “Important Safety Instructions” at the
front of this manual to disconnect, then reconnect in correct polarity.

Charging the Battery

1. Press Battery Type selector until desired battery type LED lights.

Note:

The default selection is “GEL” type battery.

2. Press 4/10/20/50 AMP button to begin charging at the 4 amp rate; the unit

sounds a beep and the charging current LED lights. The charger starts charging
at 4 amp rate automatically if 4/10/20/50 AMP button is not pressed within
3 minutes after applying AC power.
If the Display on the charger varies between “F03” and the amp rate, the battery
is sulfated and the charger is trying to give it some charge. If after approximately
2 hours the display just shows “F03”, then the battery will not charge.
Charger occasionally sounds a beep and displays “0.0” during self-test or
charging stage changes.

3. Pressing the 4/10/20/50 AMP button again advances charging rate to 10

amps, pressing once more advances charging rate to 20 amps, and again to 50
amps. (Pressing the button again will turn OFF the charger output and the Display
will show “000”.) This selection and actual battery charge rate are monitored by
the microprocessor, and the unit will stop charging if the selected rate is too fast
or too slow for battery size or condition.
As the battery nears full charge capacity, the unit’s output will automatically drop
to a lower charge rate.
Pressing the 4/10/20/50 AMP button repeatedly advances to standby mode;
the unit sounds a beep, displays “000” and stops charging.

4. The battery charger displays the charge current. To view the battery voltage,

press BATTERY VOLTAGE button. The charger will sound a beep and display the
battery voltage for 3 seconds, then returns to displaying the charge current.

5. The display shows “FUL” when the battery is fully charged.
6. Follow the steps outlined in “Important Safety Instructions” at the front of this

manual to disconnect.

4

CONTROL PANEL LED INDICATORS:

WET — 

lights when battery type selector is on WET battery type

GEL —

lights when battery type selector is on GEL battery type

AGM — 

lights when battery type selector is on AGM battery type. 

Float Charge —

lights when automatic charge monitoring is active. This feature

allows a battery to maintain its’s charge over long periods of non use. If there is any
loss of power to the charger once power is restored charger will automatically return
to the default settings. Battery selector type would be “GEL”.

Battery Voltage —

lights when battery voltage is displayed. 

Alternator Good — 

lights when load or not load checks show the alternator is

keeping up with the electrical load.
BUTTON (TO THE RIGHT OF LEDS):

Equalize — 

a recessed button used to start the equalize process.

OPERATING INSTRUCTIONS

Ensure that all installation and operating instructions and safety 
precautions are understood and carefully followed by anyone
installing or using the charger. Follow the steps outlined in “Important
Safety Instructions” at the front of this manual.  

Charge Rate Selection

After charger clamps are correctly connected, plug in the charger to a 120 volt AC
outlet and the charger will show a circulating pattern on the Digital Display, indicating
power has been applied. Select the proper charge current rate based on battery size.
Press the 4/10/20/50 AMP button and the charger will begin charging at 2 amps.
Pressing the 4/10/20/50 AMP button again will advance the charge rate to 10
amps, again to 20 amps, and again to 50 amps. Pressing the switch again will turn
OFF the charger output and the display will show “000.”

VEC1098A_Manual_022405  2/24/05  6:08 PM  Page 4

Содержание 4/10/20/50 Amp 12 Volt Smart

Страница 1: ......

Страница 2: ...l For a battery without cell caps maintenance free carefully follow manufacturer s charging instructions 5 Study all battery manufacturer s specific precautions such as removing or not removing cell caps while charging and recommended rates of charge 6 Area around battery should be well ventilated while battery is being charged Gas can be forcefully blown away by using a piece of cardboard or othe...

Страница 3: ... lead acid batteries conventional automotive maintenance free marine deep cycle and gel used in cars trucks farm equipment boats RVs and SUVs awn mowers garden tractors motorcycles personal watercraft snowmobiles ATVs and various applications Smart Battery Chargers feature 3 stage high efficiency charging technology built in microprocessor control that ensures fast safe and complete charging of se...

Страница 4: ...tery Recond is an automatic mode that once started continues for 24 hours and then stops A series of electrical pulses breaks the crystalline form of lead sulfate o return these chemicals into useful battery electrolytes More than 24 hours may be needed to restore Periodic reconditioning is recommended to maintain a battery s optimum performance However if 5 cycles does not improve battery perform...

Страница 5: ...pressed within 3 minutes after applying AC power If the Display on the charger varies between F03 and the amp rate the battery is sulfated and the charger is trying to give it some charge If after approximately 2 hours the display just shows F03 then the battery will not charge Charger occasionally sounds a beep and displays 0 0 during self test or charging stage changes 3 Pressing the 4 10 20 50 ...

Страница 6: ...t at starting the engine if needed 5 During the rest period the battery is charging at 50 amps After engine starts follow the steps outlined in Important Safety Instructions at the front of this manual to disconnect Recondition Mode Whenever a lead acid battery begins to discharge lead sulfate an insulator begins o build up on the battery s internal plates This reduces the ability of the battery t...

Страница 7: ...damage to the cords WARNINGS Do not use charger if cords or clamps have been damaged in any way call Technical Support toll free at 866 584 5504 There are no user serviceable parts in this unit Do not open the unit In the event of malfunction it must be returned to manufacturer for professional testing and repair OPENING THE UNIT WILL VOID THE MANUFACTURER S WARRANTY TROUBLESHOOTING Display Indica...

Страница 8: ...11 ...

Отзывы: