Vector Fog VECTORFOG H400 Скачать руководство пользователя страница 7

 

MAINTENANCE 

Cleaning the Chemical Tank and Pipes 

 

Fill the chemical tank with 25% of clean water and turn on the unit. Then open the chemical supply and close valves 
to flush it through. This will prevent corrosion and the accumulation of chemical deposits in the tank and pipes.

 

Spark Plug Maintenance 

  
Remove the spark plug using a spanner or spark plug remover. Remove any carbon deposits between the electrode 
and the earth section with a wire brush. Make sure that there is a space of 3.5 mm between the electrode and the 
earth. 

 

 

Fuel injector Maintenance 

 
Unscrew the fuel injector situated on the side of the carburettor. Clean the injector with compressed air to remove 
any blockages. 

Important: Never use a metallic punch to clean the injector. The injecting hole is calibrated for 

optimum performance

 

 
STANDARD SYSTEM 

  

  

  

 

SF MODEL 

  

  

  

 

  

  

  

 

Содержание VECTORFOG H400

Страница 1: ...isk of fire CAUTION MARKS Please read this manual before using the equipment You must wear protective equipment face breathing mask protective clothing gloves etc when handling potentially hazardous c...

Страница 2: ...Fuel Petrol Fuel Consumption 1 8 Litres Per Hour Start Automatic Fuel Tank Capacity 3 8 Litres Performance 23kW 30 08 hp Weight net 36 Kg Dimensions 162 x 110 x 58 cm Additional Features Tool Kit Clea...

Страница 3: ...r are all housed inside of the main body of the machine Operating at its optimum performance combustion and injection is repeated with a frequency of around 200 250 cycles per second Once the machine...

Страница 4: ...power supply is being used 110 220 volts Connect the charger to the unit and then connect to the mains When first purchased the machine requires around 8 to 10 hours to fully charge Fill the fuel tan...

Страница 5: ...ank cap tightly To turn on the machine Press the power button START and keep it pressed for 8 to 10 seconds once you hear combustion starting sounds like small explosions After the engine starts leave...

Страница 6: ...the Chemical Supply Valve clockwise to stop the supply of chemical to the resonator Before turning the Close Valve off keep it running for 5 10 seconds to get rid off any chemical mixture still in th...

Страница 7: ...spark plug using a spanner or spark plug remover Remove any carbon deposits between the electrode and the earth section with a wire brush Make sure that there is a space of 3 5 mm between the electrod...

Страница 8: ...embled The distance between the petal valve and the valve plate o should be approximately 1 mm COMMON TROUBLESHOOTING If there is no ignition If there is noise coming from the engine but there is no i...

Страница 9: ...sure the seal in the petrol cap is not damaged Make sure the cap is firmly closed to prevent leakage Unscrew the fuel injector and examine that the injector hole is not blocked If blocked clean with...

Страница 10: ...ng compressed air to remove any blockages Check there is no leaks in the chemical tank Blow compressed air backwards though the chemical tube from the inlet nozzle to see if any bubbles appear Replace...

Страница 11: ...0 Engine 11 Ejection nozzle 12 Nozzle 13 Ring 14 Nut 15 Engine upper pipe 16 Plug 17 Plug cap 18 Metal grip 19 O ring 20 Engine rear peg 21 Reducer 22 Run tee 23 Elbow 24 Explosion pipe 25 Air gasket...