TECHNICAL SPECIFICATIONS 

 

These specifications are subject to changes without notice. 
 
Input impedance                                   

superior to 30 kOhms 

Sensitivity                                                        300 mVrms 
Output power                                         

2 x 100 W (1kHz  8 Ohm) 

                                                                      2x 150 W (1 kHz  4 Ohm) 
Frequency response                                  

10 Hz – 40 KHz   +/- 0,5 dB 

Non-linear distorsion                                   

moins de 0,08% (1  kHz  90 W  8 Ohm) 

Signal to noise ratio                                  

Superior to 100 dB (A-weighted) 

 

Headphone/earphone terminal 

Maximum output level                          

superior to 6 Vrms/600 Ohm 

Ouput impedance                               

60 to 600 Ohm 

 
 

Overall 
 

Power supply determinate by switch          

230 V (+/- 5%) 50 Hz   500 VA (max.) pour Europe 

 

 

115 V (+/- 5%) 50 Hz   500 VA (max.) USA/Japan 

 

 

Fuse Specifications : 115V T6A,  230V T3A 

Working environment             

Temperature:   5°C to 40°C 

                                                                     Humidity          35% to 80% 
Dimensions (WxHxD)                                    

434 mm x 105 mm x 358 mm  

Shipping weight                                        

12 kg 

 

Weight and dimensions are approximates. 

                                      

 

IR remote control

 

 
Maximum working distance                              larger than 7 m 
Effective angle for IR receiving            

=/- 15° 

Battery                                                       

2 x AAA 

 
 

Содержание AI4

Страница 1: ...VECTEUR AI4 Hi EndIntegrated Amplifierfor Music Copyright Vecteur Mosquito 2007 Manual Ai 4 ...

Страница 2: ... amplifier without any additional energy consumption Our XDrive A technology enables to keep working in Class A at high power when most of the amplifiers go down in Class B under these conditions Sound quality and high dynamics which are the mark of excellence of class A are maintained well beyond normal limits The care we put in designing the power supply stage the fact that we use components sel...

Страница 3: ...fire or electric shock so check the power cord periodically If damage is found contact your closest service agent as well as replace the damaged power cord This unit should not be used neat water for example rain showers high humidity environments or near flower vases water pails or kitchen sinks Important if water or fluids get into the unit this may cause sever damages If water or fluids get int...

Страница 4: ...te control has 2 buttons for volume control By pressing the key the volume will be increased and by pressing the key it will be reduced If you press on of them continuously the volume will be changed continuously too During this operation the signal indication light will flash quickly to indicate that the remote control is working normally Use alkaline batteries inside the remote control If the IR...

Страница 5: ...tput to speakers will be switched off 5 Volume control knob Volume adjustment when you turn the knob clockwise volume increases counter clockwise it is reduced 6 CD input terminal Used to connect signal coming from a CD player 7 DVD input terminal Used to connect signal coming from a DVD player 8 Aux 1 Aux 2 input terminal Used to connect signal input coming from any source matching input terminal...

Страница 6: ...t cable and plug and check clean them from time to time in order to ensure that your hifi system works in the best possible conditions If the signal interconnect cable plug is pushed or pulled out while the unit is working it could damage the unit Any connection of a source with the amplifier must be conducted with the unit off Connection of speaker cables The amplifier has 2 pairs of high quality...

Страница 7: ...our speakers Avoid extreme high volume when the amplifier is working Instruction for button knobs located on the front panel Input Signal Selection Button There are 5 input signal terminals available for selection By pressing a certain button the corresponding signal will be put into the preamplifier Power On Off button The power on off button controls the power on or off of the unit When this but...

Страница 8: ...uperior to 100 dB A weighted Headphone earphone terminal Maximum output level superior to 6 Vrms 600 Ohm Ouput impedance 60 to 600 Ohm Overall Power supply determinate by switch 230 V 5 50 Hz 500 VA max pour Europe 115 V 5 50 Hz 500 VA max USA Japan Fuse Specifications 115V T6A 230V T3A Working environment Temperature 5 C to 40 C Humidity 35 to 80 Dimensions WxHxD 434 mm x 105 mm x 358 mm Shipping...

Отзывы: