background image

WARNING: Damage could be caused to the product
if the installation instructions are not followed.

• The product should 

not

be used in an ambient 

temperature higher than 40°C (104°F).

• The product should 

not

be exposed to atmospheric

agents (rain, sun, snow, etc.).

• The product or its parts should 

not

be placed in 

water or other liquids.

• Routine maintenance as described below should 

be carried out to check the condition of the fan.

• The air or fumes being extracted must be clean 

and free from greasy particles, soot, chemical and 
corrosive agents, flammable or explosive mixtures. 

The product must be installed by professionally 
qualified personnel.  Incorrect installation can 
cause damage to people, animals or property, 
for which the manufacturer cannot be held 
liable.

• The product must be connected to the electricity 

supply via a double pole switch of a suitable size, 
with contact openings of at least 3 mm.  

• If the electrical supply board (or switching device) 

is located some distance from the fan a  means of 
local isolation must be provided.

• To ensure optimum operation, do not block the 

air intake and exit vents. 

• Any ducting used must be free of blockages, and 

should be insulated if in an unheated area.

• The room where the product is operating must 

have adequate air replacement to ensure maxi-
mum effectiveness.

• If the product is sited in a room containing a fuel

burning appliance which is not of the balanced flue
type, the installer must ensure that air replace
ment is adequate both for the fan and the fuel 
burning appliance 

• The product must 

not

be used as an activator 

for water heaters, stoves, etc.

• The product must 

not

exhaust into ducts 

designed to evacuate fumes from combustion 
in stoves or other combustion-powered devices.

RANGE

Trickle Speed 1 -  8 lt/sec - 28.8 m³/h
Trickle Speed 2 - 14 lt/sec - 50.4 m³/h 
ELX1003 

- this fan combines the latest technology

with energy saving and efficiency.  It is a quiet run-
ning, 3 speed fan designed to run continuously at a
pre-selectable choice of 2 trickle speeds (see jumper
switch settings).  The user can boost the fan speed
to its maximum performance when required by
means of the cord or remove the cord and use a
remote switch, light switch, PIR sensor or humidistat.

If the fan is to be ceiling mounted, the pull-cord
switch should be put in the “off” position and the
cord removed. A remote switch will be necessary
for changing the fan speed. See wiring diagrams. 

The ELX1003 is SAP Appendix Q Listed

ELX1003DT 

- 3 speed, continuous running fan with

delay-on timer and pull cord.  The delay-on timer ver-
sion will run at low speed until the boost speed
(speed 2) is activated by means of the cord or, if the
cord is removed, by means of a remote switch, light
switch, PIR sensor or humidistat.  There is a 2
minute delay before the fan starts to run at its high
speed - if the boost speed is deactivated before that
time lapse, the fan will continue to run at low speed.
If the boost speed is activated, the fan will operate at
high speed until the boost switch is turned off. After
this, the fan will continue at high speed for the length
of time set on the timer overrun adjustment,
between 0 and 30 mins (see Trimmer Adjustment
diagram).  After the overrun time has elapsed, the
fan will return to the slower speed.

4

Содержание ELIX 1003

Страница 1: ...d continuous running SAP Appendix Q Eligible 3 models standard timer humidity control for all domestic wet rooms for walls or ceilings Energy Efficient Centrifugal Fan with EC Motor Installation and O...

Страница 2: ...people To dispose of the pack aging and the appliance at the end of its useful life refer to current recycling rules The use of any electrical product requires compli ance with some basic rules which...

Страница 3: ...ance The product must not be used as an activator for water heaters stoves etc The product must not exhaust into ducts designed to evacuate fumes from combustion in stoves or other combustion powered...

Страница 4: ...wall plugs 7 8 Decide whether to have cable access from rear recessed or top surface of fan if from top ensure that included grommet is properly fixed See dia 8 If cable is to come through rear of fan...

Страница 5: ...INSTALLATION 1 2 4 5 3 6 6...

Страница 6: ...7 8 9 10 7 INSTALLATION...

Страница 7: ...1 12 8 INSTALLATION ELXs 3 Speed with Cord WIRING DIAGRAMS ELXs 3 Speed via remote switch N B When installing fans via a remote switch pullcord switch must be left in off position and the cord removed...

Страница 8: ...DT Speed 2 Jumpers 2 and 3 To DISABLE delay on timer remove Jumper 3 TRIMMER ADJUSTMENT To adjust the humidistat and timer trimmers remove the front cover and cir cuit board cover of the fan to access...

Страница 9: ...the fan and disconnect it from the main power supply The filter can be easily removed and carefully washed The front cover can be cleaned with a dry cloth or soft brush The fan must not come into cont...

Страница 10: ...Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel 44 0 1494 522333 Fax 44 0 1494 522337 Email sales vectaire co uk Web www vectaire co uk Vectaire Ltd reserves the right to alter s...

Отзывы: