background image

8

©Vecow SEC-2000 User Manual  

GETTING TO KNOW YOUR SEC-2000

2.2.1.2  Power Button

Isolated

COM 1

Isolated

COM 2

COM 3

COM 4

DIO 1

DIO 2

LAN 1

LAN 2

VGA

HDMI

Switch

On | Off

DC-IN 12V

Isolated

COM 1

Isolated

COM 2

COM 3

COM 4

DIO 1

DIO 2

LAN 1

LAN 2

VGA

HDMI

Switch

On | Off

DC-IN 12V

2.2.1.3  PWR and HDD LED Indicator

The Power Button is a non-latched switch. To power on the system, press the power 

button and then the Green LED is lightened. To power off the system, you can either 

command shutdown by OS operation or just simply press the power button. If system 

error, you can just press the power button for 4 seconds to shut down the machine 

directly. Please do note that a 4-second interval between each 2 power-on/power-off 

operation is necessary in normal working status. (For example, once turning off the 

system, you have to wait for 4 seconds to initiate another power-on operation.)

Power LED/Green (Left) : If the LED is solid green, it indicates that the system 

is powered on. 

HDD LED/Orange (Right) : If the LED is on, it indicates that the system's storage 

is functional. If it is off, it indicates that the system's storage is not functional. If it 

is flashing, it indicates data access activities.

LED Color

Indication

System Status

Orange

HDD

•  On/Off : Storage status, function or not.

•  Twinkling : Data transferring.

Green

Power

System power status (on/off)

Содержание SEC-2000 Series

Страница 1: ...USER Manual USER Manual 1 1 0 Edition 20190314 Intel Atom x7 E3950 Apollo Lake Expandable Fanless System Isolated COM PCI PCIe Slots 40 C to 75 C Operation SEC 2000...

Страница 2: ...i Vecow SEC 2000 User Manual Version Date Page Description Remark 0 10 02 27 2019 All Preliminary Release 1 00 03 05 2019 All Official Release 1 10 03 14 2019 2 4 13 18 19 22 Update Record of Revision...

Страница 3: ...io frequency energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential...

Страница 4: ...SIM 16 GPIO Order Information Part Number Description DDR3L8G Certified DDR3L 1866 1600 8G RAM DDR3L4G Certified DDR3L 1866 1600 4G RAM PWA 160W WT 12V 160W 12V 85V AC to 264V AC Power Adapter with 3...

Страница 5: ...C 2000 series 5 CHAPTER 2 GETTING TO KNOW YOUR SEC 2000 6 2 1 Packing List for SEC 2000 6 2 2 Front Panel I O Functions 7 2 3 Main Board Expansion Connectors 15 2 4 Main Board Jumper Settings 34 CHAPT...

Страница 6: ...Setup 49 4 2 Main Menu 50 4 3 Advanced 50 4 4 Chipset 56 4 5 Security 62 4 6 Boot 63 4 7 Save Exit 64 APPENDIX A GPIO Guide 65 APPENDIX B Software Functions 68 APPENDIX C RAID Functions 70 APPENDIX D...

Страница 7: ...IEEE 1588 Precision Time Protocol PTP 4 COM RS 232 422 485 with 2 Isolated protection 16 GPIO 4 USB SIM socket for WiFi 4G 3G LTE GPRS UMTS 2 PCI PCIe slots 2 Mini PCIe expansion 1 SATA III 1 mSATA 1...

Страница 8: ...SATA III SIM socket for WiFi 4G 3G LTE GPRS UMTS 12V DC Power Input TPM 2 0 supported 1 3 Product Specification 1 3 1 Specifications of SEC 2220 System Processor Intel Atom x7 E3950 processor Apollo L...

Страница 9: ...nterface 3 pin Terminal Block V V Frame Ground Remote Switch 2 pin Terminal Block Others TPM Optional Infineon SLB9665 supports TPM 2 0 LPC interface Watchdog Timer Reset 1 to 255 sec min per step HW...

Страница 10: ...e USB SIM card 1 Mini PCIe for PCIe USB Optional mSATA PCI PCIe 1 PCIe x16 Slot 1 PCI Slot PCIe x1 signal supported Graphics Processor Intel HD Graphics 505 Interface HDMI Up to 3840 x 2160 30Hz Locka...

Страница 11: ...unt by mounting bracket Environment Operating Temperature 40 C to 75 C 40 F to 167 F Storage Temperature 40 C to 85 C 40 F to 185 F Humidity 5 to 95 Humidity non condensing Relative Humidity 95 at 85...

Страница 12: ...Utilities DVD Wall mounting bracket Foot Pad Screws Terminal block 1 2 4 Below Item Description Outlook Usage P N Qty 1 PHILLPIS M4x16L with washer Ni Mount 53 24D6416 30B 4 2 PHILLPIS M2 5x6L Ni Min...

Страница 13: ...000 Front I O Functions Isolated COM 1 Isolated COM 2 COM 3 COM 4 DIO 1 DIO 2 LAN 1 LAN 2 VGA HDMI Switch On Off DC IN 12V 2 2 1 1 Reset Tact Switch It is a hardware reset switch Use this switch to re...

Страница 14: ...an just press the power button for 4 seconds to shut down the machine directly Please do note that a 4 second interval between each 2 power on power off operation is necessary in normal working status...

Страница 15: ...itch On Off DC IN 12V Onboard VGA Port supports auxiliary channel mode The connection supports up to 1920 x 1440 resolution at 60Hz Isolated COM 1 Isolated COM 2 COM 3 COM 4 DIO 1 DIO 2 LAN 1 LAN 2 VG...

Страница 16: ...e 2 USB 2 0 connections available supporting up to 480MB per second data rate Isolated COM 1 Isolated COM 2 COM 3 COM 4 DIO 1 DIO 2 LAN 1 LAN 2 VGA HDMI Switch On Off DC IN 12V 2 2 1 7 USB 3 0 There a...

Страница 17: ...d COM 1 Isolated COM 2 COM 3 COM 4 DIO 1 DIO 2 LAN 1 LAN 2 VGA HDMI Switch On Off DC IN 12V 2 2 1 9 10 100 1000 Mbps Ethernet Port There are 2 8 pin RJ 45 jacks supporting 10 100 1000 Mbps Ethernet co...

Страница 18: ...eep twinkling off when Ethernet data packets are being transmitted received LED Location LED Color 10Mbps 100Mbps 1000Mbps Right Green Orange Off Solid Green Solid Orange Left Yellow Twinkling Yellow...

Страница 19: ...8 CTS CTS 9 RT CTS 2 2 1 11 GPIO Isolated COM 1 Isolated COM 2 COM 3 COM 4 DIO 1 DIO 2 LAN 1 LAN 2 VGA HDMI Switch On Off DC IN 12V There is a 16 bit GPIO connection Please refer to below table to see...

Страница 20: ...k You could turn on or off the system power by using this contact This terminal block supports dual function of power on power off instant off or delay 4 second and suspend modes Isolated COM 1 Isolat...

Страница 21: ...JPS2 CN5 CN11 CN12 CN1 CN2 J1 JDIO2 JDIO1 CN10 JUSB1 VGA2 JHDD1 SO DIMM1 CN14 CN18 CPU_FAN1 JPWBTN1 JRESET1 JSTATUS1 JP6 JP5 JP2 JP3 JP7 JP4 SW3 Isolated COM 1 Isolated COM 2 COM 3 COM 4 DIO 1 DIO 2 L...

Страница 22: ...Pin No Description JPWBTN 1 GND 2 FP_PWR_BTN_IN JRESET 1 GND 2 FP_RST_BTN_N JSTATUS 1 PWR_LED_N 2 PWR_LED_P JHDD 1 HDD_LED_N 2 HDD_LED_P 1 2 3 3 Battery BAT The SEC 2000 real time clock is powered by...

Страница 23: ...Pin No Definition 1 USB_VCC 2 USB_VCC 3 USB_VCC 4 USB_D_4N 5 USB_D_4P 6 USB_D_5N 7 USB_D_5P 8 GND 9 GND 10 GND 1 10 JUSB1 There are 3 audio connectors Mic in Line in and Line out in the top side of S...

Страница 24: ...lectrical pinout assignments on their connectors You can adjust JP5 to choose mSATA or Mini PCIe function The pin assignments of CN15 and JP5 are listed in the following table JP5 Pin No Function 1 3...

Страница 25: ...ux 40 GND 37 GND 38 USB_D 35 GND 36 USB_D 33 PETp0 34 GND 31 PETn0 32 SMB_DATA 29 GND 30 SMB_CLK 27 GND 28 1 5V 25 PERp0 26 GND 23 PERn0 24 3 3Vaux 21 GND 22 PERST 19 Reserved 20 reserved 17 Reserved...

Страница 26: ...of CN13 are listed in the following table Pin No Signal Name Pin No Signal Name 51 Reserved 52 3 3Vaux 49 Reserved 50 GND 47 Reserved 48 1 5V 45 Reserved 46 Reserved 43 GND 44 Reserved 41 3 3Vaux 42...

Страница 27: ...RS 232 If you want to change to RS 422 or RS 485 you can find the setting in BIOS BIOS Setting Function COM 1 CN6 Isolated COM 2 CN7 Isolated COM 3 CN8 COM 4 CN9 RS 232 RS 422 5 wire RS 422 9 wire RS...

Страница 28: ...R RXD RXD 5 CTS CTS 6 TXD RXD RXD 7 RTS RTS 8 RXD TXD TXD DATA 9 DSR RTS 10 DCD TXD TXD DATA 10 1 2 3 9 VGA SEC 2000 supports VGA under auxiliary channel mode and up to 1920 x 1440 pixels resolution T...

Страница 29: ...ions available supporting up to 480MB per second data rate in the top side of SEC 2000 CN12 2 3 11 CN11 USB 3 0 There are 2 USB 3 0 connections available supporting up to 5GB per second data rate It i...

Страница 30: ...100Mbps 1000Mbps Right Green Orange Off Solid Green Solid Orange Left Yellow Twinkling Yellow Twinkling Yellow Twinkling Yellow 1 8 2 3 12 CN5 LAN There are 2 8 pin RJ 45 jacks supporting 10 100 1000...

Страница 31: ...are listed in the following table Pin No Signal Name Pin No Signal Name 1 PANEL_VDD 2 TXO0 3 PANEL_VDD 4 TXO0 5 PANEL_VDD 6 TXO1 7 GND 8 TXO1 9 GND 10 TXO2 11 GND 12 TXO2 13 GND 14 TXOC 15 GND 16 TXOC...

Страница 32: ...power to LCD display The pin assignments are listed in the following table Pin No Signal Name Pin No Signal Name 1 5V 2 12V 3 12V 4 LBKLT_CTL 5 GND 6 GND 7 LBKLT_EN 1 7 2 3 14 CN18 Power Input SEC 20...

Страница 33: ...hich is selected by jumper JP5 The pin assignments of CN1 and CN2 are listed in the following table Pin No Signal Name Pin No Signal Name 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND 1 7 2 3 16 J1 SATA P...

Страница 34: ...Name Pin No Signal Name A1 P3V3 B1 P3V3 A2 P3V3 B2 P3V3 A3 P3V3 B3 P3V3 A4 N C B4 N C A5 GND B5 S_SMB_CLK A6 GND B6 S_SMB_DAT A7 GND B7 GND A8 12V_EN_R B8 GND A9 GND B9 N C A10 GND B10 P3V3_A A11 BUF...

Страница 35: ...e GF2_DP B25 GND A26 CLK_PCIe GF2_DN B26 GND A27 GND B27 GND A28 GND B28 GND A29 GND B29 GND A30 N C B30 N C A31 P3V3 B31 P5V A32 P3V3 B32 P5V A33 P3V3 B33 P5V A34 P3V3 B34 P5V A35 P3V3 B35 P5V A36 P3...

Страница 36: ...2 3 19 JPS2 PS 2 Mouse Keyboard Pin Head Pin No Signal Name Pin No Signal Name 1 SIO_MCLK 2 SIO_MDAT 3 GND 4 SIO_KCLK 5 SIO_KDAT 6 VCC5_KBMS 1 6 JPS2 FAN power connector supports for higher thermal re...

Страница 37: ...to GPI or GPO Please refer to below table to see the pin definition in details JDIO1 and JDIO2 Pin define are as below Pin No JDIO1 Definition JDIO2 Definition 1 SIO_GPO70 SIO_GPI80 2 SIO_GPO71 SIO_GP...

Страница 38: ...that the system is powered on HDD LED LED2 If the LED is on it indicates that the system s storage is functional If it is off it indicates that the system s storage is not functional If it is flashin...

Страница 39: ...l GETTING TO KNOW YOUR SEC 2000 2 3 23 Reset Tact Switch SW3 It is a hardware reset switch Use this switch to reset the system without power off the system Press the Reset Switch for a few seconds and...

Страница 40: ...Front View of SEC 2000 Main Board With Jumper Location JP6 JP2 JP3 JP5 JP4 JP7 2 4 2 JP3 LVDS Module Power Selection JP3 JP3 provides LVDS voltage selection function closing Pin 1 2 is for 3 3V LVDS p...

Страница 41: ...2 4 4 JP5 CN13 mSATA Mini PCIe CN1 SATA NC select JP5 Pin No CN15 CN1 1 3 2 4 mSATA N C N C Mini PCIe Default SATA Default 2 4 1 3 2 4 5 JP2 Backlight Control Level Select JP2 JP2 provides LVDS backli...

Страница 42: ...W YOUR SEC 2000 2 4 6 JP4 USB Power Select JP4 Pin No Function 1 2 5V Standby Power Default 2 3 5V System Power 1 3 2 4 7 JP7 GPI Signal Pull High Power Rail Select JP7 Pin No SIO_GPI80 to SIO_GPI87 1...

Страница 43: ...37 Vecow SEC 2000 User Manual SETUP 3 SETUP 3 1 How to Open Your SEC 2000 Step 1 Please place your SEC 2000 like this Step 2 Remove eight PHILLIPS M3 screws...

Страница 44: ...38 Vecow SEC 2000 User Manual SETUP Step 3 Please place the system like below image Step 4 Remove six PHILLIPS M3 screws Step 5 Finish...

Страница 45: ...39 Vecow SEC 2000 User Manual SETUP 3 2 Installing DDR3L Module Step 1 Find DDR3L SO DIMM socket Note only Non ECC supported Step 2 Install DDR3L RAM module into SO DIMM socket Step 3 Finished...

Страница 46: ...40 Vecow SEC 2000 User Manual SETUP 3 3 Installing Mini PCIe Card Step 1 Find Mini PCIe socket Step 2 Install Mini PCIe card into socket Step 3 Fasten a PHILLIPS M2 5 screw...

Страница 47: ...41 Vecow SEC 2000 User Manual SETUP 3 4 Installing Antenna Cable Step 1 Check antenna cable washer and nut Step 2 Install antenna cable and then fasten washer and nut 1 2...

Страница 48: ...42 Vecow SEC 2000 User Manual SETUP Step 2 Open situation 3 5 Installing SIM Card Step 1 Push SIM card slot cover to open...

Страница 49: ...43 Vecow SEC 2000 User Manual SETUP Step 3 Install SIM card and close the cover Step 4 Finish...

Страница 50: ...44 Vecow SEC 2000 User Manual SETUP 3 6 Installing SSD HDD Step 1 Remove one PHILLIPS M3x6L screw and SSD HDD bracket Step 2 Remove SSD HDD bracket...

Страница 51: ...45 Vecow SEC 2000 User Manual SETUP Step 3 Fasten four PHILLPIS M3x6L screws Step 4 Connect SATA cable and SATA power cable to SSD HDD...

Страница 52: ...46 Vecow SEC 2000 User Manual SETUP Step 5 Finish connect cable and install bracket with latch Step 6 Install the bracket and then fasten one PHILLIPS M3x6L screw...

Страница 53: ...47 Vecow SEC 2000 User Manual SETUP 3 7 Installing PCI PCIe Card Step 1 Remove one PHILLIPS M3 screw Step 2 Install PCI PCIe Card with slot Step 3 Fasten one PHILLIPS M3 screw...

Страница 54: ...48 Vecow SEC 2000 User Manual SETUP 3 8 Mounting Your SEC 2000 3 8 1 Wall Mount Fasten four PHILLIPS M3 screws...

Страница 55: ...UP BIOS SETUP 4 1 Entering Setup BIOS provides an interface for users to check and change system configuration The BIOS setup program is accessed by pressing the Del key when POST display output is sh...

Страница 56: ...n Main menu System Data Set the date Use Tab to switch between date elements System Time Set the time Use Tab to switch between time elements 4 3 Advanced Figure 4 2 BIOS Main Menu Figure 4 3 BIOS Adv...

Страница 57: ...system will enter when the SUSPEND button is pressed 4 3 2 SMART Settings Figure 4 3 2 SMART Settings SMART Self Test Run SMART Self Test on all HDDs during POST 4 3 3 IT8786 Super IO Configuration S...

Страница 58: ...onitor Settings 4 3 5 Serial Port Console Redirection Console Redirection Console Redirection Enable or Disable Console Redirection Settings The settings specify how the host computer and the remote c...

Страница 59: ...tive Processor Cores Enable this to disable core in each processor package Intel Virtualization Technology When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Te...

Страница 60: ...CPU Power Management Network Stack Enable Disable UEFI Network Stack Ipv4 PXE Support Enable Ipv4 PXE Boot Support If disabled IPV4 PXE boot option will not be created Ipv6 PXE Support Enable Ipv6 PXE...

Страница 61: ...T19 Trap Response BIOS reaction on INT19 trapping by Option ROM IMMEDIATE execute the trap right away POSTPONED execute the trap during legacy boot Boot option filter This option controls Legacy UEFI...

Страница 62: ...figuration Uncore Configuration Uncore Configuration South Cluster Configuration South Cluster Configuration 4 4 Chipset 4 4 1 North Bridge Figure 4 4 1 North Bridge Settings Max TOLUD Maximum Value o...

Страница 63: ...ection Select the target OS There are some settings difference between windows and Linux We advise you to change this option with the OS you will use 4 4 3 LVDS Configuration Figure 4 4 3 LVDS Panel S...

Страница 64: ...Primary Display Select which of IGD PCI Graphics device should be Primary Display GTT Size Select the GTT Size Aperture Size Select the Aperture Size DVMT Pre Allocated Select DVMT 5 0 Pre Allocated...

Страница 65: ...Gating PCI Express Clock Gating Enable Disable for each root port Compliance Mode Compliance Mode Enable Disable Riser Card Slot Riser Card Slot settings Intel R Ethernet Controller I210 Intel R Ether...

Страница 66: ...Selection Determines how SATA controller s operate Aggressive LPM Support Enable PCH to aggressively enter link power state Options for each SATA port Port 0 1 Enable or Disable SATA Port Spin up Devi...

Страница 67: ...pplied S5 State System keeps in power off state until power button is pressed Board Clock Spread Spectrum Enable Clock Chip s Spread Spectrum feature Wake On Lan Enable or Disable the Wake on Lan BIOS...

Страница 68: ...ure 4 5 BIOS Security Menu 4 5 1 HDD Security Configuration Set User Password Set HDD user password Advisable to Power Cycle System after Setting Hard Disk Passwords Discard or save changes option in...

Страница 69: ...er reset the mode will return to STANDARD mode Key Management Enables expert users to modify Secure Boot Policy variables without full authentication 4 6 Boot Figure 4 5 2 Security Boot Settings Setup...

Страница 70: ...hanges and Reset Reset system setup without saving any changes Save Changes Save Changes done so far to any of the setup options Discard Changes Discard Changes done so far to any of the setup options...

Страница 71: ...ctor and a watchdog timer GPIO definition is shown below APPENDIX A GPIO Guide DIO1 DIO2 Pin No GPIO Definition Pin No GPIO Definition 1 GPIO 0 11 GPIO 8 2 GPIO 1 12 GPIO 9 3 GPIO 2 13 GPIO 10 4 GPIO...

Страница 72: ...5 distribution for sample Win10_32 bat and Win10_64 bat Installation for driver and installation to Framework 3 5 distribution for sample Uninstall_32 bat and Uninstall_64 bat Uninstallation for driv...

Страница 73: ...ite button activate GPIO input pin check button read only pin 18 pin 11 pin 8 pin 1 GPIO input pin state Use for Read button activate GPIO output pin check button pin 18 pin 11 pin 8 pin 1 User settin...

Страница 74: ...or machine not match BOOL GetGPIOConfig WORD Mask Get GPIO configuration by variable Mask 15 0 In Out pin setting by hexadecimal bitmask 1 Output 0 Input Return TRUE 1 Success FALSE 0 Fail Initial er...

Страница 75: ...p Unit second Range 0 65535 sec 1093 65535 min 65580 3932100 sec Return TRUE 1 Success FALSE 0 Fail Initial error or call by pointer error or hardware problem BOOL SetWDT DWORD WDT Set watchdog timer...

Страница 76: ...2 To install Network driver 3 To install ME driver if available 4 To install Audio driver 5 To install VGA driver C 4 To Install Intel Rapid Storage Technology Software You can get the software on SEC...

Страница 77: ...Create RAID Volume on Rapid Storage Technology Software SEC 2000 is featured with three SATA devices for RAID volume so there are three options for choose on this page Let s take RAID 1 as an example...

Страница 78: ...To start Disk Management tool select initialize disk Then add Logical Device for Windows access C 8 If One SATA HDD on RAID Volume is Out of use After RAID 1 volume created you can see the figure of...

Страница 79: ...ildWhen Use DIFFERENT RAID HDD Awarning will pop up to ask you if the disk is not a member of the original RAID volume If you press Rebuild it will replace the broken SATA HDD to the last SATA HDD of...

Страница 80: ...soft Wired Keyboard 600 USB 2 USB Mouse Logitech M105 USB 3 USB Flash ADATA 3 0 16GB USB 4 USB Flash Transcend 3 0 16GB CFAST N A SATA 0 Intel SSD E5400s 120GB SATA 1 Toshiba HDD MQ01ABD050 500GB LAN...

Страница 81: ...sage with 3D Max Current Max Consumption Max Current Max Consumption Apollo Lake x7 E3950 12V 1 119A 13 43W 1 603A 19 24W D 2 Intel Atom x7 E3950 1 6GHz Apollo Lake 2M Cache up to 2 00GHz With Turbo M...

Страница 82: ...ASS PASS PASS E 2 NON ECC Brand Info Test Temp Celsius Vecow 4GB 240PIN DDR3L 1333 SODIMM M340L W28M1 25 C 25 C Kingston 2GB 240PIN DDR3L 1600 SODIMM KVR16LS11S6 2 25 C 25 C Kingston 4GB 240PIN DDR3L...

Страница 83: ...SATA Intel Intel 310 SSDMAEMC080G2 80GB SATA SSD Kingston SUV400S37 120G 120GB Innodisk 3MG2 P DGS25 64GD81BC1QC 64GB Intel SSD 540s SSDSC2KW120H6 120GB Intel SSD E 5400s SSDSC2KR120H6 120GB MEMXPRO 2...

Страница 84: ...fications are subject to change without prior notice No part of this publication may be reproduced in any form or by any means electric photocopying or recording without prior authorization from the p...

Отзывы: