![Vecow MTC-7000 Series Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/vecow/mtc-7000-series/mtc-7000-series_user-manual_3741248017.webp)
10
©Vecow MTC-7000 User Manual
GENERAL INTRODUCTION
Power
Power Input
9V to 48V, DC-in
Power Interface
3-pin Terminal Block : V+, V-, Frame Ground
Power Adapter
AC to DC 120W Power Adapter (Optional Accessory)
Surge Protection
Up to 80V/1ms Transient Power
Others
TPM
Optional Infineon SLB9665 supports TPM 2.0, LPC Interface
Watchdog Timer
Reset : 1 to 255 sec./min. per step
Smart Management
Wake on LAN, PXE supported
HW Monitor
Monitoring temperature, voltages. Auto throttling control when
CPU overheats.
Software Support
Microsoft
Window 10
Linux
Fedora 19, Ubuntu 10.04 LTS, or Linux Kernel 3.0 above
Mechanical
Dimension
537.8mm x 329.0mm x 77.1mm (21.17" x 12.95" x 3.04")
Weight
6.35 kg (13.99 lb)
Front Panel Protection IP65 Compliant
Mounting
• Panel Mount
• VESA 100/75
Environment
Operating Temperature -5°C to 55°C (23°F to 131°F)
Storage Temperature
-20°C to 60°C (-4°F to 140°F)
Humidity
10% to 95% Humidity, non-condensing
Relative Humidity
95% at 55°C
Shock
• IEC 60068-2-27
• 20G, Half-sine, 11ms
Vibration
• IEC 60068-2-64
• Non-operation : 10Hz to 200Hz, 1Grms, X, Y, Z, 30 mins
each Axis
EMC
CE, FCC