54
©Vecow EPBC-1000 User Manual
Appendix B
BOOL Set_WDT(DWORD WDT)
Set watchdog timer setup
WDT: watchdog timer setup
Unit: second. (Range: 0 ~ 65535 sec, 1093 ~ 65535 min (=65580 ~
3932100 sec))
Return:
TRUE (1): Success;
FALSE (0): Fail (Initial error, or setup 0, or hardware problem )
BOOL Cancel_WDT()
Cancel watchdog timer
Return:
TRUE (1): Success;
FALSE (0): Fail (Initial error, or hardware problem)
BOOL config_COMPORT(BYTE *PORT_NUM)
Set COMPORT configuration.
A. PORT_NUM: Usable COMPORT number.
Range: 1~2.
Return:
TRUE (1): Success;
FALSE (0): Fail (Initial error, or setup 0, or hardware problem)
BOOL set_COMPORT_mode(BYTE port, BYTE mode, BYTE term)
Set COMPORT mode.
B. port: which port set.
Range: 1~2.
C. mode: Usable COMPORT number.
0: RS232 mode; 1: RS422-5Wire mode.
2: RS422-9Wire mode; 4: RS485 mode.
4: Loopback mode.
D. term: Termination enable for RS422/RS485 mode.
1: Enable; 0: Disable.
Return:
TRUE (1): Success;
FALSE (0): Fail (Initial error or hardware problem)
BOOL get_COMPORT_mode(BYTE port, BYTE *mode, BYTE term)
Get COMPORT mode.
E. port: which port get.
Range: 1~2.
F. mode: Usable COMPORT number.
0: RS232 mode; 1: RS422-5Wire mode.
2: RS422-9Wire mode; 4: RS485 mode.
4: Loopback mode.
G.term: Termination enable for RS422/RS485 mode.
1: Enable; 0: Disable.
Return:
TRUE (1): Success;
FALSE (0): Fail (Initial error or hardware problem)
Содержание EPBC-1000
Страница 57: ...51 Vecow EPBC 1000 User Manual Appendix A Vecow_WDT...
Страница 67: ...61 Vecow EPBC 1000 User Manual Appendix E Select Browse my computer for drivers Click Browse...
Страница 68: ...62 Vecow EPBC 1000 User Manual Appendix E Click OK Select decompressed file Click Next...
Страница 69: ...63 Vecow EPBC 1000 User Manual Appendix E Update Unknown Driver successfully...