1.

 

Introduction 

1.1.

 

General information 

Thank you for purchasing a Climma CWS system! 
This manual will provide necessary information for the proper installation, operation, and maintenance of 

your Climma system.  
Climma chiller and products are designed and produced to the highest standards and they are all tested 
in the factory. If your Climma system is used according to the guidelines in this manual, it will guarantee 

you trouble free operation for many years. 
If you require assistance, please contact one of our many authorized service centers. To find the service 

center please check our website 

www.veco.net

 or write us at 

[email protected]

.  

WARNING 

This unit should only be used for the purposes for which it was designed. The manufacturer declines all 

responsibility for any damage caused by incorrect or unreasonable use, such as: 

 

improper use by untrained persons; 

 

technical modifications or operations not suited to specific models; 

 

use of non-original or non-specific spare parts; 

1.2.

 

System features 

Following the main features of the Climma DC chillers: 

 

Variable Output from a Single Air-conditioning Unit. Depending on the heat load requirements, 

the compressor frequency varies controlling the output capacity, to produce faster cooling and 

heating, significantly improving the comfort on-board.   

 

Water  Cooled  Inverter  Compressor.  Climma’s  water  cooled  inverter  protects  the  DC  brushless 

compressor from excessive temperature, current overload and irregular voltage supply, allowing 

it to be installed in the engine room without additional ventilation. Added to this, the electronic 

control  provides  continuous  monitoring  of  the  compressor  curve  to  keep  the  unit  within  safe 

operating limits, eliminating also stop-start cycles. 

 

Eco mode. This function has been specifically developed to optimize the power consumption of 
the system in three principle ways: it enables the chiller to work more efficiently with a smaller 

output generator than would ideally be required; in ECO mode the power consumption is further 

reduced during  night operation when only a  courtesy/night  generator  is working  running  and 

less  power  is  needed;  ECO  mode  allows  the  air-conditioning  to  run  while  on  the  dock  with  a 

limited shore power supply. 

 

No  Start Load.  By using  a DC compressor  with inverter  the Climma compressor  starts  at  a low 
frequency requiring a fraction of the power.   

 

Up to 50% energy saving 

A Climma centralized air-conditioning system includes different products: the Climma DC chiller, fancoils 

installed  in  each  cabins,  fresh  water  piping  that  connects  the  chiller  to  the  fancoils,  sea  water  piping 

bringing sea water to the chiller condenser, the fresh and the sea water pumps. 
While the Climma system is running in cool mode, the Climma DC chiller is cooling the fresh water that 

circulates  in  the  fresh  water  circuit  to  the  fancoils;  heat  is  removed  from  the  cabins  through  fancoils, 

blowing fresh air into the cabins. 
While in heat mode (reverse cycle mode), the Climma DC chiller is heating the fancoil water circuit that 

brings heated water to the fancoils, allowing them to blow heated air in the cabins.  

Содержание CLIMMA CWS DC INVERTER Series

Страница 1: ...Installation usage and maintenance manual CLIMMA CWS DC INVERTER Rev 141104...

Страница 2: ...ther system components sea water circuit 6 2 8 Other system components fresh water circuit 7 2 9 Electrical connections 8 2 10 Installation checks 8 3 Operating instructions 9 3 1 The electrical contr...

Страница 3: ...ture current overload and irregular voltage supply allowing it to be installed in the engine room without additional ventilation Added to this the electronic control provides continuous monitoring of...

Страница 4: ...nce all packing material has been removed check that the unit has not been damaged in any way Caution Wear protective gloves when handling any packing materials and the wood base Dispose of all packag...

Страница 5: ...unit must be secured on a surface using the mounting brackets below the drain pan WARNINGS The Climma DC chiller is provided with an inverter mounted on the unit VDF Variable Frequency Drive The inve...

Страница 6: ...ill In this case the display temperature sensor will be automatically excluded WARNING Do not place the temperature sensor on the supply air flow or close to return supply grills under the sunlight or...

Страница 7: ...The strainer has to be cleaned periodically WARNING Sea water strainer is mandatory in the seawater circuit Failure to install the sea water strainer will void the warranty SEA WATER OUTLET The sea wa...

Страница 8: ...will decrease as more water will be needed to fill the circuit therefore more antifreeze must be added to the circuit Empty the circuit from the water used for leak test Prepare an antifreeze solution...

Страница 9: ...the main power supply to the sea water pump and to the circulation pump The electrical box is already connected to the inverter the RC valve and water valve on the chiller to the electronic expansion...

Страница 10: ...stem power but this time the maximum power is limited to a specific ECO value which allows you to set a maximum power consumption lower than the maximum system power consumption Example Chiller maximu...

Страница 11: ...ntil the selector is on the value you want to change the value will blink then use the arrows UP DOWN to modify the value To confirm the value press ENTER again To go back to the main screen press ESC...

Страница 12: ...The system logs all alarms warnings and errors keeping track of all the information when the issue occurred When there is a warning error the main display will show a bell symbol to see the warning er...

Страница 13: ...e fresh water temperature SC02 Compressor speed This the real time compressor speed it varies from 20 up to 100Rps Hz SC03 Press Dischg Discharge pressure SC03 Press Suct Suction pressure SC03 EVD val...

Страница 14: ...ool and in heat mode When the system is not run for a long period it s important to manually run the pumps removing the back cover and manually rotate the cooling fan inside the pump This will extend...

Страница 15: ...below the safety levels Please check the value of the pressures and try to reset manually the alarm If it does not stop contact the closest Climma service center AL14 Min suction pressure compressor...

Страница 16: ...re compressor 4 Auto5 M 13 sec OFF compressor AL41 Envelope alarm compressor 1 Manual 60 sec OFF compressor The compressor was working outside of its safe zone therefore the system stopped Check sea w...

Страница 17: ...r disconnected AL68 Temperature sensor B6 error compressor 2 Auto 60 sec OFF compressor AL69 Temperature sensor B6 error compressor 3 Auto 60 sec OFF compressor AL70 Temperature sensor B6 error compre...

Страница 18: ...gh check the power supply then try to restart the system and reset the alarm If the error does not go eway contact the closest Climma service center 2 Motor overload The current delivered has exceeded...

Страница 19: ...reset manually the alarm then if it does not go away shut off the system wait 1 minute then try to restart the system If the error does not go eway contact the closest Climma service center 20 PFC Fai...

Страница 20: ...MP IS NOT STARTING Check the power supply to the pump check the connection from the electrical control box to the pump NB The pumps are working only when the compressor is running PROBLEM SYSTEM NOT C...