ERRORS AND LOGS 

This screen allows accessing the active errors screen and the warning/error 
log. 

 

Active errors: the screen shows all the errors, and it underlines the 
active ones with a full spot; you can also try to reset the error from 

this screen pressing “Press to reset”.

 

 

 

Error log:  the screen shows the list of the past errors, with date 
time information. 

 

INITIAL SETTINGS 

This screen allows accessing and modifying the initial board and display 
settings. 

 

Board program: from this screen, you can change the settings of 
the Compact/fancoil which have been selected during the first 
startup (see 

2.2. Initial settings at first start-up)

 

Modbus address: from this screen you can change the Modbus 
address of the electrical board (only for fancoils with MV8 control) 

 

Celsius/Farenheit: from this screen you can change the unit of 
measure used on the display, from Celsius to Farenheit, and you 
can also modify the scale used for the set-point. 

 

SERVICE 

This screen allows authorized service centers to access hidden parameters 
under password.  

 

TROUBLESHOOTING 

This screen guides the user into basic maintenance and troubleshooting of 
the unit.  In the main screen you can see some useful information on the 
system that can help in case of troubleshooting, or you can access a basic 
guide for 

Maintenance

 and 

Troubleshooting

 

DISPLAY INFO 

This screen shows the display basic information: Model, Software version 
and Board code. 

Содержание Climma C-TOUCH

Страница 1: ...Installation usage and maintenance manual C TOUCH CONTROL Rev 2 230511...

Страница 2: ...4 2 Installation 5 2 1 Climma C Touch display location 5 1 1 Cut out and display mounting 5 1 2 Battery 6 1 1 Battery change 6 2 Operating instructions 7 2 1 Home screen and symbols 7 2 2 Initial sett...

Страница 3: ...e Mk3 and EF with MK3 electronic control and with Climma fancoils with Mv8 electronic control and MCON electronic control C TOUCH can fully replace Mk3 controls and Mk2 controls considering that the M...

Страница 4: ...he recommendations of this manual are solely the responsibility of the unit operator before installation and maintenance operations disconnect the unit from the power supply failure to comply may resu...

Страница 5: ...erature therefore it s suggested to install it at the mid height of the cabin on an inside wall that provides a good air circulation The Climma C Touch display should not be installed in a position wh...

Страница 6: ...d battery type is CR2032 The battery is used only when the panel is powered off the battery will last for a minimum of 2 years when powered off When the battery dies you need to change it and then res...

Страница 7: ...ss to turn ON or OFF the fan Automatic mode when fan is in Auto mode the A is displayed on the screen 6 The bars are showing the actual fan speed through blue or red in case of heating bars 7 The symb...

Страница 8: ...has to be set depending on the system it needs to control At first startup please select the language it may be changed also later on from the Main Men The display will automatically recognize if it s...

Страница 9: ...an see it from its code as it containes the heater W value in the description e g MEVA7EJ FAN COIL EVA 7 DRY PAN J RES 1300W has a 1 3kW heater 2 3 Main menu The main menu is accessible through the ma...

Страница 10: ...nit works only in heat mode SCHEDULE In this mode the system will work based on the scheduled of the selected program see Chapter 2 4 for more LANGUAGE DATE TIME This screen allows modifying language...

Страница 11: ...rtup see 2 2 Initial settings at first start up Modbus address from this screen you can change the Modbus address of the electrical board only for fancoils with MV8 control Celsius Farenheit from this...

Страница 12: ...o to the Main Menu MAIN MENU MODE SCHEDULE From the main Scheduler screen you can Turn the Scheduler ON or OFF or access one over the 6 programs to select them check how they are configured or modify...

Страница 13: ...grammed correctly then the change over probe maybe faulty ERROR 2 Communication timeout ERROR 3 External alarm ERROR 4 Clean filter alarm This is a warning that comes every 2500 running hours and it s...

Отзывы: