background image

obr3500_ml_01_sd

Approved: 

C.H.

4-9

 5)   Click the 

Add Virtual Interface

 address button.

 6)   Enter a name for the interface into the 

Virtual Interface Name

 field.

 7)   Enter virtual IP address for the new domain that you wish to add into the 

IP Address

 field.

 8)   Enter the subnet for the new address into the 

Subnet Mask

 field.

 9)   Click the 

Add

 button.

 10)  Repeat steps 5-7 to add more Virtual Addresses.

 11)  When you are done, close the browser.

Содержание VistaMax OBR3500

Страница 1: ...INSTALLATION AND OPERATION GUIDE VistaMax OBR3500 Base Station Transceiver...

Страница 2: ...to make changes in content from time to time without obligation on the part of Vecima Networks Inc to provide notification of such revision or change Vecima Networks Inc provides this guide without w...

Страница 3: ...r the ongoing video voice and data delivery revolution Vecima Networks design powerhouse has created custom RF and digital products for technology leaders such as AT T Cisco Systems Cogeco Comcast and...

Страница 4: ...les sections sur la s curit l installation et l utilisation Conserver ce manuel pour consultation future Suivre toutes les instructions sinon vous risquez d endommager l appareil ou de vous blesser g...

Страница 5: ...ace 3 1 3 2 OBR3500 Base Station Logs 3 4 3 3 Base Station Upgrade 3 5 3 4 Service Flow 3 6 3 5 SNMP Configuration 3 8 3 6 Subscriber Station Modulation Table 3 9 3 7 Base Station Status 3 10 4 0 Base...

Страница 6: ...Table of Contents obr3500_ml_01_sd Approved C H 2 This page intentionally left blank...

Страница 7: ...r Ethernet capability Vecima Networks WES800 to supply power and provide Ethernet connectivity to the OBR3500 1 2 OBR3500 Features Benefits 802 16 2004 OFDM Compliant PHY MAC standards based radio Sof...

Страница 8: ...grated antenna 43 dBm EIRP 120 deg integrated antenna 28 dBm at external antenna connector optional Output Power 28 dBm Output Power Control Range 10 dB Spectral Mask Compliance Industry Canada RSS 19...

Страница 9: ...C H 1 3 Mechanical Item Specification Operating Temperature 45 C to 55 C Physical 20 x 8 x 5 50 8cm x 20cm x 12 7cm maximum Mounting Pole mount 2 5 to 4 5 diameter pole Weight 20 lbs 9 kg maximum Wea...

Страница 10: ...obr3500_ml_01_sd Approved C H 1 4 This page intentionally left blank...

Страница 11: ...owing hardware is included in the box for mounting the OBR3500 to the pole The Chassis Bracket and Elevation Adjustment Bracket come pre installed on the OBR3500 chassis Figure 2 1 OBR3500 Pole Mounti...

Страница 12: ...YH WKH OHYHYDWLRQ GMXVPHQW UDFNHW IURP WKH KDVVLV UDFNHW E UHPRYLQJ WKH IRXU VFUHZV RQ HDFK VLGH 5 029 5 029 KDVVLV UDFNHW OHYDWLRQ GMXVWPHQW UDFNHW WWDFK WKH KDVVLV UDFNHW WR WKH 2 5 XVLQJ IRXU EROWV...

Страница 13: ...DOOHG YLHZHG IURP WKH IDFH WKDW ZLOO PRXQW WRZDUGV WKH 2 5 6TXDUH FROODU RQ FDUULDJH EROW 7R SUHYHQW WKH VTXDUH FROODU QHDU WKH KHDG RI WKH FDUULDJH EROWV IURP VOLSSLQJ EDFN WKURXJK WKH VTXDUH KROHV I...

Страница 14: ...acket onto the opposite side as shown in Figure 2 3 Fasten a lock washer and nut onto all four carriage bolts and tighten until the OBR3500 is suitably secured in place Figure 2 4 Attaching the OBR350...

Страница 15: ...made cable assembly such as a CAT5CABLE OD 25 CAT5CABLE OD 50 CAT5CABLE OD 75 or CAT5CABLE OD 10 from Vecima Networks then a cable assembly will have to made using the Molex backshell included with t...

Страница 16: ...lap the tape by approximately one half of its width so that it can form a seal with itself Extend the wrapping to approximately one inch past the end of the connector Figure 2 6 Apply Rubber Sealing T...

Страница 17: ...ongly recommends adding a 6 to 8 inch loop for strain relief as shown in Figure 2 5 This will minimize strain to the connector resulting from changing environmental conditions Figure 2 9 Adding a Stra...

Страница 18: ...embling the OBR3500 Base Station Grounding Attach the earth ground to the grounding lug located on the base station Provided parts 1 x 5 8 inch washer 1 x 1 4 inch grounding lug Required parts 1 x 6 A...

Страница 19: ...2 11 Grounding the OBR3500 CAUTION Vecima Networks requires that the CAT5E cable to the OBR3500 is connected to a lightning surge protector at the entrance to the building prior to connection to the W...

Страница 20: ...or slice the insulation down to the five 5 inch scoring 7 Remove the insulation from the cable 8 Gently twist the metal shield to form metal ground strip 9 Make a straight through cable with the wire...

Страница 21: ...00 to the tower via the grounding lug on the back of the unit See Grounding the Base Station 2 Use a shielded CAT5 cablefeed to connect the OBR base station to the surge suppressor 3 Use an inline sur...

Страница 22: ...tation to the surge suppressor 3 Use two inline surge suppressors one for all OBR3500 cablefeed installations at the base of the tower and another for the first surge suppressor and the WES800 Connect...

Страница 23: ...interface of the OBR3500 system may be viewed with a standard web browser such as Mozilla or Internet Explorer no additional add ins are required 3 1 OBR3500 Base Station Interface The following scre...

Страница 24: ...when you change a configuration or to restart the system Select Yes to confirm the reboot Figure 3 2 Reboot page Select Apply Configuration to apply changes made to the subscriber station configurati...

Страница 25: ...obr3500_ml_01_sd Approved C H 3 3 Select Reset Configuration to reset the configuration to the basic default configuration Select Yes to confirm the reset Figure 3 4 Reset Configuration page...

Страница 26: ...H 3 4 3 2 OBR3500 Base Station Logs Select Show Log to display the log activity for the base station Figure 3 5 Show Log page Select Show SNMP Log to display the SNMP activity on the base station Fig...

Страница 27: ...e Transfer Protocol server In the top text entry box enter the address where the upgrade file is located This directs the base station to use that file to upgrade Select the Force the update check box...

Страница 28: ...ice flow is part of the Quality of Service QoS feature of the base station Use this page to assign the service class to the subscriber station MAC or to remove a QoS from a subscriber station Select S...

Страница 29: ...obr3500_ml_01_sd Approved C H 3 7 Select Classifier Template Table to define the classifier template for the QoS Figure 3 10 Classifier Template Table page...

Страница 30: ...proved C H 3 8 3 5 SNMP Configuration Select SNMP Configurations to define the SNMP community strings Currently setting the SNMP is the only way that the base station can communicate Figure 3 11 SNMP...

Страница 31: ...sd Approved C H 3 9 3 6 Subscriber Station Modulation Table Select SS Modulation Table to show the current downlink and uplink modulations for all registered SS Figure 3 12 Subscriber Station Modulati...

Страница 32: ...on Status Select General Status to display the statistics of a base station Figure 3 13 General Status page Select SS Table to display the status of subscriber stations that are connected to the base...

Страница 33: ...page This page shows the Security Association ID SAID number for MAC Addresses and displays Private Key information for those MAC addresses Select PKM TEK Table to display information about the traffi...

Страница 34: ...obr3500_ml_01_sd Approved C H 3 12 This page intentionally left blank...

Страница 35: ...e station To configure the network 1 Open a web browser and connect to the web GUI for the OBR3500 base station by entering the following IP address in the address line of your browser https IP of the...

Страница 36: ...ccess the web GUI If you have entered the information correctly the following page displays 3 Click on the Configuration folder in the left side menu This will expand the folder content Click on the R...

Страница 37: ...kHz Frame Duration The combined Downlink and Uplink frame length in milliseconds Click the drop down menu arrow and select the duration 5 0 ms Cyclic Prefix The redundant symbol percentage used to co...

Страница 38: ...de to the system is listed here Click the Yes button to apply the changes 8 If you have made Radio Configuration changes click the Reboot link on the left side menu This will reset the Base Station wi...

Страница 39: ...address of you Base Station To change the IP address on the base station 1 Open a web browser 2 Enter the current IP address of the Base Station into the address line https 192 168 101 2 cgi bin index...

Страница 40: ...is point you may need to change the IP configuration of the computer which you are using to access the base station If you have completely changed the domain for the Base Station was 192 168 101 1 now...

Страница 41: ...displayed on the window to indicate the change When the IP address changes the address on the browser will change to reflect the new IP address 13 If you were not able to reconnect and click the here...

Страница 42: ...ation from more than one domain By entering the different IP addresses into the Base Station you will be able to access the Base Station from various different domains To add a Virtual IP Address 1 Op...

Страница 43: ...ace into the Virtual Interface Name field 7 Enter virtual IP address for the new domain that you wish to add into the IP Address field 8 Enter the subnet for the new address into the Subnet Mask field...

Страница 44: ...ystem To upgrade the Base Station through the web GUI 1 Open the browser 2 In the Address line enter the IP address of the Base Station 3 Click the Upgrade BS Software link on the left side menu 4 Cli...

Страница 45: ...ny errors close the browser If Then The upgrade file is located on the tftp server in the tftproot folder 1 Enter the IP address and upgrade file name in the tftp location of upgrade line tftp ip of N...

Страница 46: ...obr3500_ml_01_sd Approved C H 4 12 This page intentionally left blank...

Страница 47: ...e one pictured below R M A service is available Monday to Friday from 8 30 a m to 4 30 p m CST statutory holidays excepted To obtain an R M A do one of the following Call 306 955 7075 press 0 for Oper...

Страница 48: ...hat no fault is found the item is subject to the current Test Fee and will be exempt from warranty 5 Any product exhibiting external damage either from shipping improper handling or use will be subjec...

Страница 49: ...tower site Once the Ethernet cable termination is repaired the cable feed will no longer be susceptible to interfering radiation and the data will be secured Figure A 1 JMRJ45S 15 Modular Plug NOTE Ot...

Страница 50: ...that comes with the package Figure A 2 Molex Backshell Elements Molex backshell component parts 1 Coupling ring 2 Cable seal assembly might already be threaded to into part 3 3 Plug holder 4 Basket se...

Страница 51: ...WKH SDFNDJH 6WHS 3ODFH WKH DEOH 6HDO VVHPEO RXSOLQJ 5LQJ DQG 3OXJ ROGHU RQWR WKH FDEOH DV VKRZQ W LV YLWDO WKDW WKH LWHPV DUH SODFHG RQ WKH FDEOH LQ WKH FRUUHFW RUGHU 127 RRVHQ WKH EDFN HQG RI WKH DE...

Страница 52: ...them Fold the stranded wire back over the foil See Figure Figure A 5 below for a picture of wires prepared for insertion into the connector sleeve Figure A 5 Preparing the wires for insertion in conne...

Страница 53: ...e A 6 2 You can see the copper ends of the wires If the wires are not snug against the connector end the connection will be intermittent After ensuring that the cable is prepared correctly crimp the c...

Страница 54: ...A 6 Step 5 After crimping the cable cut a two inch piece of ZTHS 50 01 heat shrunk protective sheath and place it over the connector and a leading piece of cable See Figure A 10 Figure A 10 Connector...

Страница 55: ...6HDO VVHPEO 6WHS 3XVK WKH 5 FRQQHFWRU LQWR WKH 3OXJ ROGHU XQWLO LW LV VQXJ DJDLQVW WKH 5HDWDLQHU HGJH DQG WKHQ WLJKWHQ WKH UHDU RI WKH DEOH 6HDO VVHPEO WR KROG WKH FDEOH LQ SODFH KHQ LQVHUWLQJ WKH 5 F...

Страница 56: ...obr3500_ml_01_sd Approved C H A 8 This page intentionally left blank...