background image

TROUBLESHOOTING

PROBLEM

PROBABLE CAUSE

SOLUTION

On giving a command with

the remote

control  or  with  the

key-switch, the gate

doesn’t open or the motor

doesn’t start

230  volt  mains  voltage

absent

Check master switch

Emergency STOP present

Check  for  any  STOP

selectors or commands.

If not used, check jumper

on STOP contact input on

the control board

Fuse blown

Replace with one of same

value.

Power cable of motor or

motors not

connected or faulty.

Connect  the  cable  to

appropriate

terminal or replace.

The  photocell  is  not

functioning or the

beam is interrupted

Check  the  connection,

remove any

obstacle across the beam

On giving a command with

the remote control, the

gate doesn’t open but

works  with  the  key

command

The remote control has not

been

memorised or the battery

is flat

Carry  out  the  remote

control learning

procedure on the radio
receiver  or  replace  the
battery with a new one..

The gate starts, but stops

immediately

The force of the motor or

motors is insufficient

Modify the value with the

FORCE trimmer on the

control unit

One wing opens and the

other closes

The  connection  is  not

correct

Invert the connection of

the  cable  of  the  motor

which rotates in the wrong

sense

N.B. - If the problem persists, contact your Retailer or the nearest Service
Centre

Содержание AMICO 400DG

Страница 1: ...horoughly read this manual that is an integral part of the pack The CE mark conforms to European directive EEC 89 336 92 31 93 68 D L 04 12 1992 N 476 Our products if installed by qualified personnel capable to evaluate risks comply with norms UNI EN 12453 EN 12445 AMICO 400DG ...

Страница 2: ...3 TECHNICAL DATA 3 DIMENSIONS 4 TYPICAL CONNECTION AND CABLE SECTION 4 CONSIDERATIONS FOR INSTALLATION 5 INSTALLATION 5 6 TROUBLESHOOTING 7 SAFETY PRECAUTIONS 8 PACKING CONTENTS 1 OPERATOR 1 KIT FASTENING PLATES AND RELATIVE ACCESSORIES 1 UNLOCKING KEY 1 CONDENSER 230Vca ...

Страница 3: ...ng temperature 20 C 55 C weight 8 5 Kg Protection rating IP 55 Opening time 90 20 sec Rod stroke 400 mm Force of thrust 1500 N Motor current input 3 A 1 A 2 5 VIEW OF TYPICAL AUTOMATION AND NAMES OF COMPONENTS 4 3 1 1 5 6 7 8 Optimal installation 1 Operator 2 External photocell 3 Flashing warning light 4 Antenna 5 Internal photocell 6 Electronic control unit 7 Key switch 8 Remote control TECHNICAL...

Страница 4: ...DIMENSIONS TYPICAL CONNECTION AND CABLE SECTION 2X1 5mm2 24 Vdc 4X1 5mm2 230 Vca 2X0 75mm2 4X0 75mm2 4X0 75mm2 2X0 75mm2 105 mm 825 mm 110 mm 400 mm 3X1 5mm2 230V Line RX Photocell TX Photocell ...

Страница 5: ...ngs well on its hinges and is suitably lubricated It must also comply with the safety standards in force in the country of installation 1 Before fastening the brackets provided establish the coordinates using the data given in Table 1 bearing in mind that they are valid if the operator is at maximum extension minus one centimetre of the available stroke CD when the gate is closed to obtain maximum...

Страница 6: ...S FIG 1 FIG 2 40mm A B Fix the back plate to the pillar FIG 1 Anchor the rear part of the piston to the plate and fasten it firmly FIG 2 1 Fit the anchor plate onto the piston fig 4 2 Close the gate 3 Move the piston with the plate already fitted towards the gate 4 Move the fitting to limit stop then move it back by approximately 1 cm and mark the position of the plate 5 realize the same operation...

Страница 7: ...g or the beam is interrupted Check the connection remove any obstacle across the beam On giving a command with the remote control the gate doesn t open but works with the key command The remote control has not been memorised or the battery is flat Carry out the remote control learning procedure on the radio receiver or replace the battery with a new one The gate starts but stops immediately The fo...

Страница 8: ...rity safety and operation in the event incompatible devices and or components are installed Solely original spare parts should be used for repairs and replacements The installer must provide all the information relating to the operation maintenance and use of the individual parts components and system as a whole WARNINGS FOR THE USER Read the instructions and enclosed documentation carefully The p...

Отзывы: