II
• E
01
/2
00
9
39
The steps involved in measuring and testing
Road measurement
6.1.1
Automatic Measured Track
1
Position the vehicle in front of the start reflector stand.
2
Press
to start the "Automtic measuring track" menu.
The CTC II reads the tachograph type.
3
Drive along the measured track at a steady speed.
4
End of measurement. Continue program.
When the vehicle has been driven past the end reflector
stand, an acoustic tone sounds and the determined values
are displayed.
5
Press
to adjust the K value to match the determined W value.
The CTC II programs the determined W value in the
tachograph.
Remark:
The K value may deviate by ± 2 imp/km from the determined
W value, due to electronic splitting.
6
End the program.
If the determined characteristic coefficient "W" deviates by
±1% from the set device constant, the K value must be
adjusted accordingly.
◄
Important