* Parameters ALFANET 71

Para-
Meter

Description Parameter

Range

Standard
value

01

02

03

Function Relay 1

Function Relay 2

Function Relay 3

1=Cool
2=Heat
3=Alarm
1=Cool
2=Heat
3=Alarm
1=Cool
2=Heat
3=Alarm

1

2

3

05

06
07

Function sensor-2

Offset temperature sensor-1
Offset temperature sensor-2

0=Not
1=Control
2=Alarm
-15.0..+15.0°C
-15.0..+15.0°C

0

0.0
0.0

10

11

12
13
14
15
16
17
18
19

Switch on relay 2 by

Switch on relay 3 by

Switch on delay relay 2
Switch on delay relay 3
Switching differential relay 1
Setpoint offset relay 1
Switching differential relay 2
Setpoint offset relay 2
Switching differentia relay 3
Setpoint offset relay 3

0=Temperature
1=Time
0=Temperature
1=Time
0..99 Minutes
0..99 Minutes
0.1..15.0
-15..+15
0.1..15.0
-15..+15
0.1..15.0
-15..+15

0

0

15
15

0.5
0.0
0.5
0.0
0.5
0.0

20
21
22

23
24

Switch on delay cooling
Switch off delay cooling
Parameter 20/21 in Sec. or Min.

Minimum on-time cooling
Minimum off-time cooling

0..99
0..99
0=Seconds
1=Minutes
0..99 Minutes
0..99 Minutes

0
0
0

0
0

25
26
27

Minimum setpoint
Maximum setpoint
Read-out above -10°C per 1°C

-50.0..+50.0°C
-50.0..+50.0°C
0= No
1= Yes

-50
+50

0

30

31
32
33
34
35

36

37

Alarm type (to setpoint)

Minimum alarm setpoint
Maximum alarm setpoint
Time delay minimum alarm
Time delay maximum alarm
Relay function alarm relay

Reset alarm relay after recovering alarm

Reset alarm relay after manual reset

0= None
1= Absolute
2= Relatief
-50.0..+50.0°C
-50.0..+50.0°C
0..99 min.
0..99 min.
0= Watch
1= Control
0= No
1= Yes
0= No
1= Yes

1

-50
+50

0
0
0

0

0
0

40
41

Start up delay after power failure
Forced relay function, at sensor failure

0..99 Minutes
0= None 
1= Cool
2= Heat

0
0

50

Time correction (at realtime clock)

-99..+99

0

90
95
96
97
98
99

Network number
Software version
Production year
Production week
Serial number (x1000)
Serial number (units)

1..250
0..255
00..99
1..52
0..255
0..999

1
0
0
1
0
0

Содержание ALFANET 71

Страница 1: ...t By pushing the SET key the setpoint appears in the display The decimal point of the last display starts blinking A few seconds after releasing the SET key the setpoint disappears and the measured temperature is shown again in the display Changing setpoint Push the SET key and the setpoint appears in the display Release the SET key Now push the SET key again together with the UP or DOWN keys to c...

Страница 2: ...ctly E1 Sensor 1 failure Check sensor 1000Ω at 25 C E2 Sensor 2 failure Replace sensor EEE Settings are lost Solution EEE Reprogram the settings L In case of sensor short circuit the display alternates between error code E and L as indication for a short circuit sensor H In case of open circuit sensor the display alternates between error code E and H as indication for a open circuit sensor Reset A...

Страница 3: ...delay cooling Switch off delay cooling Parameter 20 21 in Sec or Min Minimum on time cooling Minimum off time cooling 0 99 0 99 0 Seconds 1 Minutes 0 99 Minutes 0 99 Minutes 0 0 0 0 0 25 26 27 Minimum setpoint Maximum setpoint Read out above 10 C per 1 C 50 0 50 0 C 50 0 50 0 C 0 No 1 Yes 50 50 0 30 31 32 33 34 35 36 37 Alarm type to setpoint Minimum alarm setpoint Maximum alarm setpoint Time dela...

Страница 4: ...4 Connections Dimensions Address VDH Products BV Tel 31 0 50 30 28 900 Produktieweg 1 Fax 31 0 50 30 28 980 9301 ZS Roden Email info vdhproducts nl The Netherlands Internet www vdhproducts nl ...

Отзывы: