background image

1

BatteryMINDer

6 Volt Battery Charger/Maintainer/Conditioner 

with 

PulseMode

Circuit 

and 

AUTOFLOAT CONTROL

Quick-Start Instructions for BatteryMINDer 

Use ONLY after reading full Safety Instructions located inside.

1. Plug battery clip assembly (supplied) into 

mating plug at end of 

BM output cord OR 

attach Ring Terminal Assembly (supplied) 

to your battery’s terminals (Red +  Blue -)

2. Attach battery clips to posts or terminal 

clamps of battery (Red + Black -) (Green 
indicator will light when proper connection 
is made)

3. Plug 

BM into AC electrical outlet.

(Red indicator lites up) 

4. Allow 72 hours MAXIMUM (1 - 4 batteries) 

for Green indicator to blink (If Green 
indicator does not blink within 72 hours 
Press de-sulphation button) 
(blinking = full charge with battery in 
maint desulphation mode) 
(blinking will continue indefinitely, until 
disconnected from battery)

Note: RED indicator will remain lit when plugged into

live ac electrical outlet. It 

should never go out, unless

outlet is switched off or 

BM has failed

HOW TO QUALIFY  YOUR BATTERY

You have purchased the number #1 rated “Computer Chip” charg-
er  / maintainer / conditioner with both Auto-Float Control™ and the
newest technological innovation Pulse Mode™ Circuitry. Although
designed primarily for use with flooded electrolyte -maintenance
type lead acid batteries, including marine deep cycle, it can be
used effectively with ALL maintenance-free types as well. Please
carefully follow these special instructions and the standard safety
and operating instructions for both maximum safety and complete
performance satisfaction.

Note: If your battery does not have a “resting”* voltage of 

5.25

volts MINIMUM

it cannot be charged or de-sulphated. (*Resting

voltage = Voltage in a battery that has not been charged or 
discharged within 8 hours MINIMUM).

It is extremely important that you determine the state of your bat-
tery’s “Health” before attempting to re-charge and re-condition your
battery. If any of your cells are shorted ( no reading on the hydrom-
eter tester) or the difference in charge level is greater than 0.50 SG
between any 2 cells (=  2 ball difference using the hydrometer
tester supplied ), your battery cannot be properly re-charged / re-
conditioned. Discard the battery in an appropriate, lawful manner.

Do not attempt to connect or charge ANY battery with the

BatteryMINDer

Charger / Maintainer / Conditioner before testing

your battery in accordance with the following: Your battery must not
be charged or dis-charged for a minimum of 10 hrs. Testing a bat-
tery which has not been at “rest” for 10 hrs. min. will result in inac-
curate readings.

Maintenance / Maintenance Free lead acid batteries 

(with filler caps or  manifold type covers) 

CAREFULLY

remove all 3 caps or both manifold type covers from

your battery. Carefully check water / electrolyte level. If level is now
or has ever been below top of plates, severe lead plate
“Sulphation” has taken place. Significant re-charge / re-condition-
ing time (weeks to months) will be needed to re- store those plates
to a condition were they can be expected to function normally.
Refill each cell with Distilled Water Only to a level of 1/4” minimum
over the top of the cell’s plates. Recharge the battery using

BatteryMINDer

to ensure it is slowly and completely charged

before determining its condition. If 

Battery-MINDer

fails to “blink”

within 72 hours, your battery may be to far gone to be re-condi-
tioned. However, to be sure press the de-sulphation button to set
the unit in the PulseMode. Allow battery to remain in this mode for

minimum of 72 hrs

before testing for “dead cells”, using the

special Hot / Cold calibrated Hydrometer Tester supplied. Here is
what to do:

NOTE: Read Tester Instructions carefully for best most accurate
readings.

Fill the Tester to a level sufficient to “float” all of the “balls”. Note the
number of balls which float in each of the 3 cells. If no balls float in
a cell, you can consider the cell to be “shorted”. Your battery is
beyond the point of being properly re-charged or re-conditioned.
Dispose of battery. If each cell “floats” 2 or more balls your battery
can be re-conditioned. Simply leave 

BatteryMINDer 

connected to

your battery at all times it is not in actual use, year-round. Your
unit’s special high frequency-current pulses will continue to bom-
bard the crystallized sulfuric acid, which has become deposited on
your battery’s cell plates.

NOTE: You cannot over de-sulphate your battery

.

IMPORTANT !

Read these special instructions before attempting to desulphate your battery.

Содержание BatteryMINDer

Страница 1: ...ttery cannot be properly re charged re conditioned Discard the battery in an appropriate lawful manner Do not attempt to connect or charge ANY battery with the BatteryMINDer Charger Maintainer Conditioner before testing your battery in accordance with the following Your battery must not be charged or dis charged for a minimum of 10 hrs Testing a bat tery which has not been at rest for 10 hrs min w...

Страница 2: ... charger from outlet before attempting any maintenance or cleaning 7 WARNING RISK OF EXPLOSIVE GASES WHENEVER YOU WORK NEAR A LEAD ACID BATTERY IT IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY To reduce risk of battery explos...

Страница 3: ...der the load and perform much like a battery that was not fully charged in the first place Buy a good quality replacement battery and take proper care by keeping your BatteryMINDer connected to your bat tery at all times this means all year round it is not in use for 4 days or more Remember your BatteryMINDer uses less than a dime s worth of electricity per month running 24 hrs per day and it is w...

Страница 4: ...D TO YOUR BAT TERY AT ALL TIMES THE BATTERY IS NOT IN SERVICE WILL AFFECT PERFORMANCE CLAIMS ONE 1 YEAR 100 UNCONDITIONAL MONEY BACK GUARANTEE BatteryMINDer is Guaranteed to perform as claimed or WE will refund your full purchase price including all taxes shipping or handling cost applicable to the purchase Unit must be returned with Proof of Purchase directly to VDC Electronics Inc NOT TO THE DEA...

Отзывы: