by
1.11
1.12
1.13
1.21
1.22
1.31
1.32
1.33
Modulator
There are several options for powering the RF Distribution
Module.
Directly via connection of the supplied 12V DC 1.5 Amp
Plug pack to the 12 VDC Power Input jack F on the unit.
(Use in the event that a modulator is not included in the
system)
Remotely via a modulator connected to MOD RF IN input
E on the RF Distribution Module. If powering this way
press Remote Power button on the rear of the IR Modulator
to ‘ON’. In this setup, DO NOT connect a Plug Pack directly
to the RF Distribution Module.
Remotely, via a Power Injector (RL-RF900) connected to
the cable terminating on the MOD RF IN input E (see
Instal Manual for Power Injector). For use in the event
that a modulator is not included in the system, but remote
powering of the RF Distribution Module is required.
Auxiliary Devices such as modem/router can be powered
using 3.5mm to 3.5mm DC lead connected to G .
NOTE - Output power = 12VDC with max. current 800mA.
INSTALLATION MANUAL
RF Distribution
WARRANTY
Vcomm Pty Ltd states that the warrant that the customer can rely on is that
provided by the manufacturer. In the event of any warranty claim please
contact us and we will forward it to the manufacturer. The manufacturer will
then determine the extent of their liability. This expressly negates, to the
extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.
ABN: 99 091 281 524
Vcomm Pty Ltd
www.resi-linx.com
Patented
RL-RF380
Radio Frequency Range
resi-linx
RF Distribution Module
C
B
E
A
D
Remote
Control
IR Target
Antenna
IR Emitter
12V DC 1.5A
G
1.1 DC In Connection
1.2 DC Out Connection
If using Modulator for Pay TV/DVD etc, connect RF output
on rear of modulator to MOD RF IN Input E on RF
Distribution Module. This input must be used to remotely
power the RF Distribution Module and allow IR pass
throughout the system.
A modulator connected to CCTV devices (if required)
can be connected to AUX MOD RF IN Input C on RF
Distribution Module.
Connect the off-air signal (antenna) to the ANT RF IN Input
A on the RF Distribution Module.
Connect up to 8 TV outputs B .
Factory settings are at maximum gain.
In the event of distortion of modulator signals, reduce Gain
Control J by turning knob anti-clockwise until distortion is
gone.
NOTE
- Gain control reduces the (ANT) antenna signal
Optimal results are attained when ANT signal is within
15db of the modulator signal.
1.3 Hardware Connection
1.4 Gain Control
Connect to modem/router
(Max current 800mA)
F
H
I
N15275
®
¸
1.41
1.42
1.43
A Antenna RF Input
B TV Inputs
C Auxilliary Mod RF Input
D Protective Earth Connection
E Modulator RF Input
F 12V DC Input
G 12V DC Output
H IR Emitter Port
I FM Trap
J Gain Control
J