28
© 2009 VBrick Systems, Inc.
Passthrough State: Initiator
Operational State
Describes the current status of a Passthrough connection, including
error conditions, if any. Refer to the Monitor > Network page. This
will display "Active" if in Passthrough mode.
Passthrough State
Initiator – In this case it will continuously attempt to automatically
initiate a Passthrough connection to the remote destination. This
mode also offers metadata destination options.
Destination
Read-only: Dedicated.
Dedicated Destination The VBrick appliance (whose serial port is the destination of this
COM port) can be configured and identified using either an IP
address or a host name.
Dedicated Port
Default - 4439.
Baud Rate
Rate of Passthrough port. Rate can be set to the following (Default
= 9600): 110, 300, 600, 1200, 2400, 3600, 4800, 7200, 9600, 14400,
19200, 28800, 38400, 57600, 115200.
Stop Bits
Number of stop bits for Passthrough port (1 or 2).
Parity
None, Even, Odd.
RTS Control
Force OFF, Force ON or Automatic. If automatic, the control will
be on when Passthrough is active.
Note
:
DTR and RTS are not available for COM. Under no
conditions are RTS or DTR controls passed through end-to-end.
All control handling is local.