background image

 

 

1  Overwiew  

All devices of brand 

uni

qu

om

 

are battery-operated, electric handhelds to control special 

devices with RR 485-based interfaces (i.e. EC-Drives from different brands).  

2  General Description 

A clear and simple menu guide has been realised bilingual (English/German). The amber 
lighted  full  graphic  display  is  designed  for  comfortable  use  at  all  lighting  conditions.  The 
Mini-USB-link  can  be  used  for  Battery  charge  as  well  as  a  data  interface.  A  5V-Power 
supply with a wide selection of variable, removable adapters that fit numerous different AC 
outlet  sockets.  The  flexible  design  offers  possibilities  for  a  customized  OEM-solution  in 
front design and software.     
 

 

 

3  Operation 

3.1  Operating conditions 

 

All  devices  of  series 

uni

qu

om

  are  designed  for  an 

indoor usage. Make sure to protect from humidity and 
rain if you use it outside.  

Shock 

 

 

Warning 

Do not drop the device or expose to sudden shock.   
 
Do not use the device in an area where it is likely to 
be exposed to constant vibration higher than  
2,5 mm*s

-1

.   

 

Temperature 

 

 

Warning 

Do not use or store device outside temperature range 
of 

0°C … 40°C.   

 
 
 
 
 

Содержание Uniquom

Страница 1: ...vbk technology uniquom Manual uniquom EN 2 04 2017 07 ...

Страница 2: ...ning caution marks incl all warning labels placed at the equipment Make sure that the warning labels are kept in good condition and replace missing or damaged labels For further Information vbk technology GmbH Verlängerte Goethestraße 9 08209 Auerbach Tel 49 0 3744 22 47 914 Fax 49 0 3744 22 35 595 info vbk technology de www vbk technology de ...

Страница 3: ...ed personal only Only qualified person s must operate with the present device This qualified personal must be familiar to these types of products and associated with danger and risks authorized to install mount commission and use these types of product Intended Use Use this device only in the manner intended by the manufacturer according to the manual and only in combination with the described pro...

Страница 4: ...ng instructions within easy reach of the equipment and make them available to all users Whenever measuring or testing has to be performed on live equipment suitable electronic tools should be used Before installing and commissioning please read these safety instructions and warnings carefully and all the warning labels attached to the equipment Transport and Storage Warning Correct transportation ...

Страница 5: ...and Service on the device may only be carried out or advised by vbk technology Warning Li Ion chargeable battery inside The battery may explode when mistreated Do not overload shortcut disassemble or dispose of in fire ...

Страница 6: ... 7 3 2 General Properties of the Device 8 3 3 Inputs and Outputs 9 3 4 Interface General Information 9 4 Menu Structure 10 4 1 Software 10 4 2 Menustructure Basisvariation 10 5 Technical Data 11 6 Additionnel Hints 12 6 1 Manufacturing 12 6 2 Packing and Shipping 12 6 3 Service 13 7 Notices 14 ...

Страница 7: ... A 5V Power supply with a wide selection of variable removable adapters that fit numerous different AC outlet sockets The flexible design offers possibilities for a customized OEM solution in front design and software 3 Operation 3 1 Operating conditions All devices of series uniquom are designed for an indoor usage Make sure to protect from humidity and rain if you use it outside Shock Warning Do...

Страница 8: ...300mAh USB interface incl 5V power supply automatic charge state detection incl safety switch off Battery fully charged Battery in charge Battery low Use Handheld for inside application protection grade IP20 acc EN 60529 Temperature 0 C 40 C ambient temperature at stock and usage Display Amber coloured full graphic display Access easy access push encoder IGR Time base Real time clock ...

Страница 9: ... for battery charge and as data link 3 4 Interface General Information Hardware Structure according RS485 Specification Half duplex 1 8 Load up to 256 points max 400m wiring length Characteristic Baud rate 9600 19200 38400 57600 Parity none even odd Stop bits 1 2 Supported Features According connected device RS485 Fieldbus USB Interface ...

Страница 10: ...edback Broadcast Control Parameterizing of all connected devices without feedback broadcast Datalog Log function for single device and save in the external flash 4 2 Menustructure Basisvariation Main level Sublevel 1 description Properties Back to main level Change Language English Deutsch Set Clock date rime Timeout Light Time to switch off display lighting Update Firmware Service feature coded S...

Страница 11: ...le colour full graphic display with background lighting Access easy access push encoder IGR Dimensions in mm Weight 350g Accessory included 5V Power supply with a wide selection of variable removable adapters that fit numerous different AC outlet sockets Accessory on demand Data cable 1 50m Phoenix Contact RJ45 USB Data cable 1 80m USB A mini USB B 38 185 98 ...

Страница 12: ...rogrammer tool contents a single Lithium Ionen Battery Energy 100Wh For Airfreight of more than 2 devices per package packing and marking are in accordance to IATA Dangerous Goods Transport Regulations required Some forwarders Airlines refuses airfreight of Lithium Ionen Batteries in general For Export uniquom is categorized to the following HS code 85176200 Machines for the reception conversion a...

Страница 13: ... 3 Service Technical queries about uniquom under vbk technology GmbH Verlängerte Goethestraße 9 08209 Auerbach Tel 49 0 3744 22 47 914 Fax 49 0 3744 22 35 595 info vbk technology de www vbk technology de ...

Страница 14: ...7 Notices ...

Страница 15: ......

Страница 16: ...vbk technology info vbk technology de www vbk technology de ...