Installation Steps

1. Slide off mounting plate in back of the light.

2. Install the mounting plate to the wall or mounting surface by using drywall screws (B).

 

If mounting to a wooden surface, drill three 3/32 in. holes into the mounting surface. Install the two mounting

 

screw, through the mounting plate and into the mounting surface.

 

If mounting to wall board or brick, drill three 7/32 in. holes into the mounting surface. Insert the wall anchors (A)

 

and attach the mounting plate using the three mounting screws.

3. Slide the light fixture back onto the mounting plate.

4. Place the solar panel to the wall and mark drilling location. Use an electrical drill (not included) to drill two holes

    into the mounting surface. Then install the solar panel the same way as the mounting plate to the wall using

    drywall screws (B) with or without anchors (A). (See Fig.1)

    

Note: The solar panel is equipped with a 16ft. (5M) connecting wire, so the light fixture and solar panel

    can be installed up to 16ft. (5M) apart.

5. Connect the cable from solar panel to the bottom of light panel to the bottom of light fixture. Only use the included 

    solar panel to charge the light, any other external charger may damage the light fixture. (See Fig.2)

Page 2 / 5

C

Fig.3

Adjusting the Sensor Head (C): 

1. Aim sensor head toward desired detection area, maintaining a 5° - 40° downward

    angle to allow moisture to drain.

    Note: Make sure sensor head is positioned with controls facing toward the ground.

2. You can rotate the sensor head up and down to change the coverage area.

(See Fig.3)

Note: Range set too high may increase false triggering. 

(See Fig.4 and Fig.5)

Sensor Adjustment Higher For Long Coverage

Sensor Adjustment Lower For Short Coverage

Fig.4

Fig.5

Sensitivity of Motion Sensor 

   (See Fig.10)

Adjusting the Light Head (B): 

1. Adjust the light head up or down, left or right for desired area.  

    Keep the light heads at least 1" (25mm) away from the sensor.

    (See Fig.6)

2. Keep the light heads (B) face down around 30 degrees angle 

    to avoid water damage.

You can adjust the sensitivity of the motion sensor by using the

"SENS" selector located on the right side of the sensor head. 

Adjust motion sensor sensitivity to HIGH (H), MEDIUM (M), 

or LOW (L) to achieve desired performance.

Approximate range for each setting: 50 ft. (H), 32 ft. (M), 16 ft (L).  

For eave mounted only:

Swing the sensor head towards the mounting surface.

Rotate the sensor head unclockwise 180˚ so the controls face down.

Backplate

Controls

Controls

Controls

Fig.6

231130

Содержание T0723

Страница 1: ...Mounting Surface Mounting Plate Drywall Screw Anchors Slide Down Page 1 5 Note Fixture can be wall mounted or eave mounted Wall Mounted Eave Mounted Light fixture and sensor should be mounted as shown...

Страница 2: ...ge the light any other external charger may damage the light fixture See Fig 2 Page 2 5 C Fig 3 Adjusting the Sensor Head C 1 Aim sensor head toward desired detection area maintaining a 5 40 downward...

Страница 3: ...detected the light turns to high level brightness 5000K and stays on as long as there s motion being detected After there s no further motion being detected the high level brightness 5000K will remain...

Страница 4: ...timate that the batteries will last between 75 and 450 days using the assumptions below 450 days per day 450 days 75 days per day 75 days 2 Insert the Alkaline batteries or replace the rechargeable ba...

Страница 5: ...wer supply power surges or dips For coastal locations some corrosion is considered normal for the environment Vaxcel reserves the right to repair replace or issue a credit for any properly installed p...

Страница 6: ...o Anclajes Deslice hacia abajo Nota El artefacto se puede instalar en la pared o en el alero Montaje en la pared Montaje en el alero El artefacto de iluminaci n y el sensor deben montarse como se mues...

Страница 7: ...ar el artefacto de iluminaci n Vea la Fig 2 C Fig 3 Ajuste m s alto del sensor para cobertura extensa Ajuste m s bajo del sensor para cobertura corta Fig 4 Fig 5 Solo para el montaje en un alero Mueva...

Страница 8: ...odo de prueba La luz se enciende al brillo de nivel alto 5000K cuando se detecta movimiento y permanece encendida mientras se detecte movimiento Cuando ya no se detecte movimiento durante 5 segundos v...

Страница 9: ...imento y abrir la cubierta Vea la Fig 13 3 Ajuste los dos tornillos de la parte posterior del artefacto de iluminaci n para asegurar el compartimento Vea la Fig 15 4 Tres bater as alcalinas tipo C t p...

Страница 10: ...cciones uso con suministro de corriente inadecuado sobretensiones o ca das de energ a En las zonas costeras una cierta corrosi n se considera normal para el medio ambiente Vaxcel se reserva el derecho...

Страница 11: ...vers le bas Remarque Le luminaire peut tre fix au mur ou sur l avanc e de toiture Montage mural Montage sur l avanc e de toiture Le luminaire et le d tecteur doivent tre mont s comme indiqu ci dessus...

Страница 12: ...olaire est quip d un fil de connexion de 5 m 16 pi de sorte que le luminaire et le panneau solaire peuvent tre install s une distance maximale de 5 m 16 pi l un de l autre 5 Connectez le c ble du pann...

Страница 13: ...mouvement est d tect Si aucun mouvement n est d tect pendant 5 secondes la lumi re revient une luminosit faible 2700 K puis s teint automatiquement apr s 5 secondes suppl mentaires si aucun autre mouv...

Страница 14: ...compartiment et tirez sur le couvercle pour l ouvrir Voir Fig 13 3 Serrez les deux vis l arri re du luminaire pour fixer le compartiment Voir Fig 15 4 Trois piles alcalines C courantes dureront 10 he...

Страница 15: ...e des surtensions ou des baisses de tension Dans les r gions c ti res une certaine corrosion est consid r e comme normale pour l environnement Vaxcel se r serve le droit de r parer de remplacer ou d a...

Отзывы: