The following parts are available for re-order if damaged or missing.
Mounting Strap
Decorative cover
Fixture Mounting Screw
A: 6-3/4"
B: 10-3/4"
C: 5-3/4"
Troubleshooting
---The light does not work.
1. Make sure the wall switch and circuit breaker are on.
2. Make sure the wiring is correct.
3. Cover the sensor with dark color cloth to verify that the ambient light level is not too high.
---The light comes on for no apparent reason:
1. Re-aim the motion sensor.
2. Decrease the sensitivity setting.
3. Do not use a dimmer or timer to control the light fixture. Replace the dimmer or timer with a standard on/off wall
switch.
---The light flashes on and off:
1. Reposition the light head away from the motion sensor.
2. Reposition the motion sensor.
3. The motion sensor is in “TEST” mode and warm up.
Mounting Screw X2
#8/32X1/2 in
Mounting Screw X2
#6/32 X1/2 in
Mounting Screw X2
#10/24 X1/4 in
Assembly Kit
6613MM (1 SET) FOR T0700
6614MM (1 SET) FOR T0701
Wire Connector
Gasket
4. The sensor will be more sensitive to motion across its detection
path than motion directly towards it. (See Fig.9)
5. To reduce possible nuisances, do not mount the fixture near a heat
source like an air conditioner, vent or furnace exhaust, or in a
direction facing any reflective object or other nearby light source.
Fig.9
Motion
Least sensitive
Motion
Most sensitive
Sensor