ASSEMBLY  AND  INSTALLATION 

                INSTRUCTIONS

NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements.

           

    2. READ AND SAVE THESE INSTRUCTIONS.  

T0112

Bulb Type A Max.100W

       (not included)

150110

Loop 

Fixture

Mounting Strap (A)

Mounting Screw (B)

Green Grounding 

     Screw (C)

Wire Nut (D)

Canopy (I) 

Loop Lock (K)

Chain (L)

Outlet Box

House Grounding Wire

Wire Nut (D)

Fixture Wire

Fixture Grounding Wire

Mounting Strap (A)

Green Grounding Screw (C)

Mounting Screw (B)

Threaded Pipe(G)

Canopy (I)

Top Loop (H)

Hex Nut (E)

Washer (F)

Collar (J)
Loop Lock (K)

Loop Lock (K)

Chain (L)

Hex Nut (E)

Washer (F)

Threaded Pipe(G)

Top Loop (H)

Collar (J)

1. Attach threaded pipe to the mounting strap, then secure it 

    with a  washer and hex nut.

2. Attach the mounting strap to the outlet box by using two 

    mounting screws.

3. Secure the top loop to threaded pipe.

4. Secure the loop onto the stem of the fixture, thread fixture 

     wires through threaded end of loop first.

5. Connect the chain:

    - Determine length of chain needed to achieve desired fixture

       height. (To remove excess chain section, use plier to bend

       link open.)

    - Weave the fixture wires through the chain, collar and canopy.

6. Connect one end of the chain to the loop using a loop lock.

7. Connect the other end of the chain to the top loop using the

     other loop lock.

8. Thread the fixture wire and fixture grounding wire through the top

     loop, threaded pipe and mounting strap.

9. Pull out the source wires from the outlet box. Make wire connections

     using wire nuts as follows:

     ---Connect the smooth-coated wire (marked) from the fixture to the black wire from the power source.

     ---Connect the ribbed-coated wire (unmarked) from the fixture to the white wire from the power source.

     ---Attach the fixture grounding wire to the mounting strap with the green grounding screw. Then connect it to the house

         grounding wire with a wire nut.

    Carefully put the wires back into the outlet box.

Hardware Package (included):

Turn off the power at fuse or circuit box.

   

   

Installation Steps

 

WARNING: Turn off the main power at circuit breaker before installing fixture.

AVERTISSEMENT: Coupez la source d’alimentation principale au panneau 

central de disjoncteurs avant d’installer le luminaire.