background image

T0103 --- Page 5 / 5

Assembly Kit

5077MM 

(1 SET)

The following parts are available for re-order if damaged or missing.

Troubleshooting

---The light does not come on at all:

1. Make sure the wall switch and circuit breaker are on.

2. Make sure the wiring is correct.

3. Cover the sensor with dark color cloth to verify that the ambient light level is not too high.

---In TEST mode, the light stays on over 5 seconds after motion is no longer detected:

1. Cover the sensor with a dark color cloth to verify that motion is not detected.

2. The TEST mode may have expired. If you want to reactivate the TEST mode, reboot the power

---In AUTO Mode, the light stays on during the day:

1. The light may be in TEST mode. Stay out of the detection range for 5 minutes, which will allow conversion to 

    AUTO mode.

---In 3H or 6H Mode, the light is still on full brightness, even though it has been 3 hours or 6 hours after dusk:

1. Make sure there has not been an interruption in the electrical power, i.e. the wall switch has not been switched off 

    and turned back on at some point or the circuit breaker had not shut down. 

---After performing 3H or 6H Mode, the light stays on full brightness after 3 minutes:

1. Make sure there is no movement that could be picked up by the sensor.

2. Adjust the delay time knob counterclockwise to reduce the delay shut-off time.

---In Manual override, the light stays on after dawn:

1. The ambient light level may be too low due to overcast skies.

Mounting Screw (A)

Mounting Screw (B)

Mounting Bracket Screw (D)

Fixture Mounting Screw (F)

Mounting Strap (E)

Mounting Screw (C)

Wire Nut (G)

140919

A: 13-1/8"
B: 9"
C: 6-3/8"

Содержание T0103

Страница 1: ...Wall Mounted Eave Mounted Light fixture and sensor should be mounted as shown above when installed depending upon type of installation Before installing the light fixture under an eave the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock For eave mounted only Swing the sensor head towards the mounting bracket Rotate the senso...

Страница 2: ...all the UP arrow must point upward See Fig 1 When mounting to an eave the UP arrow must point toward the building 5 Attach the back plate of the light fixture to the mounting bracket secure it with the fixture mounting screw 6 With silicone caulking compound caulk completely around where the mounting bracket meets the wall surface CAUTION Be sure to caulk completely where the mounting bracket meet...

Страница 3: ...on stops the light will then revert to low level brightness after the shut off delay time you set 5 180 seconds The light will turn off automatically at dawn Note You can adjust the low level brightness 0 50 by using the low level brightness knob See Fig 7 2 3 HOURS 3H MODE nighttime operation only The light will turn to high level brightness 100 at dusk and will stay ON for 3 hours The light will...

Страница 4: ...ht will turn to high level brightness 100 at dusk and will stay ON for 6 hours The light will then turn to low level brightness The light will turn to high level brightness 100 when motion is detected and will stay on as long as motion continues When motion is no longer detected the lights will remain on for the predetermined shut off delay time you set 5 180 seconds and then turn to the predeterm...

Страница 5: ...out of the detection range for 5 minutes which will allow conversion to AUTO mode In 3H or 6H Mode the light is still on full brightness even though it has been 3 hours or 6 hours after dusk 1 Make sure there has not been an interruption in the electrical power i e the wall switch has not been switched off and turned back on at some point or the circuit breaker had not shut down After performing 3...