background image

140919

T0101 / T0102 --- Page 2 / 2

Mounting Screw (A)

Mounting Screw (B)  

Mounting Bracket Screw (D)

Fixture Mounting Screw (G)

Decorative Cover(F)

Mounting Strap (E)

Mounting Screw (C)

Wire Nut (H)

Turn on the power at the main fuse or circuit breaker box.

2. Install the mounting strap with the stamped word “FRONT” facing 

    away from the outlet box, using two mounting screws that best fit the 

    outlet box.

3. Pull out the source wires from the outlet box. Make wire connections 

     using wire nuts as follows:

     ---Connect the black wire from the fixture to the black wire from the 

         power source.

     ---Connect the white wire from the fixture to the white wire from the 

         power source.

     ---Connect the grounding wire from the fixture to the grounding wire 

         from the power source. (usually green / yellow insulation)

     Carefully tuck the wires back into the outlet box.

4. Place mounting bracket against the outlet box, insert the mounting 

    bracket screw through the mounting bracket hole, thread mounting 

    bracket screw into the center hole of the mounting strap. Tighten the 

    mounting bracket screw securely.

    ▲   When mounting to a wall, the “UP” arrow must point upward. 

          (See Fig. 1)

    ▲   When mounting to an eave, the “UP” arrow must point toward 

           the building.

5. Attach the back plate of the light fixture to the mounting bracket, secure it with the fixture mounting screw. 

6. Push the decorative cover firmly into the fixture mounting screw hole on the light fixture.

7. With silicone caulking compound, caulk completely around where the mounting bracket meets the wall surface.

  CAUTION: Be sure to caulk completely where the mounting bracket meets the wall surface to prevent water 

     from seeping into the outlet box.

8. Gently grasp the light heads and move them up or down, left or right to adjust the light coverage area. (See Fig. 2)

9. 

Keep the light heads 30˚ below horizontal to avoid water damage and electrical shock.

Fig. 2

Note: When power is first applied, the light will turn on immediately. Wait for 15 seconds to allow the sensor to 

warm up.

Assembly Kit

5076MM 

(1 SET)

The following parts are available for re-order if damaged or missing.

Fig. 1

A: 9-3/8"
B: 5-1/4"
C: 5-1/4"

Отзывы: