background image

T0099 / T0100 --- Page 2 / 5

Sensor

1. Aim sensor head toward desired detection area, maintaining a 

    5° - 40° downward angle to allow moisture to drain.

    Note: Make sure sensor head is positioned with control knob facing 

    towards the ground.

2. You can move the sensor head up and down to change the coverage 

    area. (See Fig. 2) Walk through the detection zone at the farthest 

    distance you wish to detect motion.

    

Note: Range set too high may increase false triggering.

 

    (See Fig. 3 and Fig. 4 on Page 3)

Adjusting the Sensor Head: 

Turn on the power at the main fuse or circuit breaker box.

sensor

Fig. 2

Installation Steps

Turn off the power at fuse or circuit box.

Mounting Strap (E)

Mounting Bracket

Outlet Box

Wire Nut (H)

Back Plate

Mounting Screw (A)

Light Head

Fixture Mounting Screw (G)

Mounting Bracket Screw (D)

FRONT

Decorative cover (F)

1. The fixture mounting bracket is pre-assembled on the light fixture. Unscrew both the decorative cover and the fixture 

    mounting screw in order to remove the mounting bracket.

2. Install the mounting strap to the outlet box with the stamped word “FRONT” facing away from the outlet box, using 

    two mounting screws that best fit the outlet box.

3. Pull out the source wires from the outlet box. Make wire connections 

     using wire nuts as follows:

     ---Connect the black wire from the fixture to the black wire from the 

         power source.

     ---Connect the white wire from the fixture to the white wire from the 

         power source.

     ---Connect the grounding wire from the fixture to the grounding wire 

         from the power source. (usually green / yellow insulation)

     Carefully tuck the wires back into the outlet box.

4. Place mounting bracket against the outlet box, insert the mounting 

    bracket screw through the mounting bracket hole, thread mounting 

    bracket screw into the center hole of the mounting strap. Tighten the 

    mounting bracket screw securely.

    ▲   When mounting to a wall, the “UP” arrow must point upward. 

(See Fig. 1)

    ▲   When mounting to an eave, the “UP” arrow must point toward the building.

5. Attach the back plate of the light fixture to the mounting bracket, secure it with the fixture mounting screw.

6. Push the decorative cover firmly into the fixture mounting screw hole on the light fixture.

7. With silicone caulking compound, caulk completely around where the mounting bracket meets the wall surface.

  CAUTION: Be sure to caulk completely where the mounting bracket meets the wall surface to prevent water 

     from seeping into the outlet box.

Fig. 1

L (Black)

N (White)

GND

140919

Содержание T0099

Страница 1: ...eeps the light OFF during daylight hours 4 When in manual override mode use wall switch to keep the light ON during the night WARNING TO AVOID RISK OF ELECTRICAL SHOCK BE SURE TO SHUT OFF POWER WHILE INSTALLING OR SERVICING THIS FIXTURE Note Fixture can be wall mounted or eave mounted Wall Mounted Eave Mounted Light fixture and sensor should be mounted as shown above when installed depending upon ...

Страница 2: ...s that best fit the outlet box 3 Pull out the source wires from the outlet box Make wire connections using wire nuts as follows Connect the black wire from the fixture to the black wire from the power source Connect the white wire from the fixture to the white wire from the power source Connect the grounding wire from the fixture to the grounding wire from the power source usually green yellow ins...

Страница 3: ... at low level brightness 0 50 The light will turn to high level brightness 100 when motion is detected It will then revert to low level brightness about 5 seconds after motion is no longer detected After expiration of the TEST mode the light will automatically enter AUTO mode and be on at low level brightness 0 50 The light will turn to high level brightness 100 when motion is detected When the mo...

Страница 4: ...light will turn to high level brightness 100 at dusk and will stay ON for 6 hours The light will then turn to low level brightness The light will turn to high level brightness 100 when motion is detected and will stay on as long as motion continues When motion is no longer detected the lights will remain on for the predetermined shut off delay time you set 5 180 seconds and then turn to the predet...

Страница 5: ...the detection range for 5 minutes which will allow conversion to AUTO mode In 3H or 6H Mode the light is still on full brightness even though it has been 3 hours or 6 hours after dusk 1 Make sure there has not been an interruption in the electrical power i e the wall switch has not been switched off and turned back on at some point or the circuit breaker had not shut down After performing 3H or 6H...

Отзывы: