FOR HOUSEHOLD USE ONLY.

When using the vacuum cleaner, basic safety precautions
should always be observed, including the following:

1.

Do not leave the carpet washer unattended when
plugged in. Unplug it from socket when not in use.

2.

To prevent electric shock do not use outdoors.

3.

Not to be used as a toy. Children should be supervised to
ensure that they do not play with the appliance.

4.

This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning the use of the appliance by a person
responsible for their safety.

5.

Use only as described in this manual.

6.

Do not use with a damaged cord or plug. If the supply
cord and/or plug is damaged, they must be replaced
by the manufacturer, a Vax Service Agent or similarly
qualified persons in order to avoid hazard.

7.

Do not pull or carry by the cord, use the cord as a
handle, allow the cord to come into contact with hot
or sharp surfaces or close a door on the cord.

8.

Do not unplug by pulling on the cord.

9.

Do not handle the plug or carpet washer with wet
hands.

10. Do not put any objects into openings or operate with

openings blocked, keep them free of anything that
may reduce airflow.

11. Keep hair, loose clothing, fingers and all parts of the

body away from openings and moving parts.

12. Do not use the carpet washer on any glowing,

burning or smoking particles.

13. Do not use without the solution tank and dirty water

tank in place.

14. Do not use the vacuum without the dust bag in place.

15. Turn off all controls before unplugging.

16. Do not use to pick up flammable or combustible

liquids such as petrol, or use in areas where they may
be present.

17. Keep the unit on the floor.

18. Do not use an extension cord.

19. Do not attempt to remove blockages with sharp

objects as they may cause damage.

20. Store indoors put away after use to prevent tripping

accidents.

21. Using improper voltage may result in damage to the

motor and possible injury to the user. The correct
voltage is listed on the rating label.

22. A hazard may occur if the carpet washer runs over

the power supply cord.

23. To prevent dirty water from running into motor, do

not hold the appliance upside-down or lay on its side.
Use appliance in normal vacuuming position.

24. Use extra care when cleaning on stairs.

25. Do not carry appliance while motor is running.

NOTE: Carpets should be dry vacuumed thoroughly
before washing.

NOTE: The unit must be unplugged from the mains
socket outlet after use, and before cleaning or
maintaining the unit.

IMPORTANT: This unit is not intended for
commercial use.

PLEASE KEEP THESE INSTRUCTIONS
FOR FURTHER USE.

!

V-027U User Guide.qxd:V-027U User Guide  11/3/08  11:46  Page 3

All manuals and user guides at all-guides.com

Содержание XL Pro V-027U

Страница 1: ...he mains cable before use Retain for future reference Vax careline 0870 6061248 instruction manual Carpet washer Vax model number V 027U ULTRA SOLUTION V 027U User Guide qxd V 027U User Guide 11 3 08...

Страница 2: ...k latch 17 Detachable tool storage 18 Hose 19 Water supply connector 20 Upholstery wash tool 21 Upholstery tool trigger 22 Solution hose clip 23 Quick cord release 24 Carrying handle 25 Clean water ta...

Страница 3: ...duce airflow 11 Keep hair loose clothing fingers and all parts of the body away from openings and moving parts 12 Do not use the carpet washer on any glowing burning or smoking particles 13 Do not use...

Страница 4: ...e cord through the slots on the back of the handle and push into place Fig 3 4 Place a nut into the recess in the back of the upper handle While holding the nut in place insert one of the large screws...

Страница 5: ...ig 3 10 NOTE The tool caddy can be removed for storage on a wall Connect upholstery attachment to end of hose by pressing until it clicks into place Fig3 11 Push upholstery attachment into the left ho...

Страница 6: ...ig 4 2 Return clean water tank by lining up the grooves of the clean water tank with the support posts on the inside of the handle Rock clean water tank inward until it locks into place Fig 4 3 Note U...

Страница 7: ...ig 4 8 Remove the hose from its stored position on the back of the cleaner Lift the hose attachment cover located on the top of the dirty water tank Fig 4 9 Insert the end of the hose into the tool op...

Страница 8: ...hose from the fitting by twisting it counterclockwise to unlock Close the hose attachment cover until it snaps into place Fig 4 15 Disconnect water supply connector from the water supply port by press...

Страница 9: ...Empty the water into the sink Fig 4 21 Dirty water tank can be rinsed out with hot tap water to remove any remaining debris Wipe and let dry thoroughly before storing to prevent mildew from forming F...

Страница 10: ...e Fig 5 1 Use a Phillips screwdriver to remove two 2 screws Fig 5 2 NOTE Phillips screwdriver required Remove the belt cover Remove the broken belt Fig 5 3 Belt or brush removal and replacement Fig 5...

Страница 11: ...n brushbar out of the cleaner Fig 5 7 To install a new brushbar Feed the brushbar through the opening until the screw plate and screw hole are lined up as above Fig 5 8 NOTE The black cap behind the s...

Страница 12: ...e page 10 PROBLEM Liquid escaping from the vacuum Cause Dirty water tank is full Solution Switch off and unplug cleaner Empty dirty water tank as shown in Section 4 Cause Dirty water tank not installe...

Страница 13: ...ge 220 240V 50Hz Wattage 750 W Capacity Clean water tank 4 0 litres Dirty water tank 3 7 litres Cord length 7 5 metres Weight 11 30kg Subject to technical change without notice V 027U User Guide qxd V...