Vax VZL-6015 Скачать руководство пользователя страница 16

www.vax.co.uk

16

clearing blockages

7. Clearing blockages

IMPORTANT: Disconnect cleaner from electrical
outlet before attempting to clear blockages.

Low suction or pick up may be due to a blockage in the
system. Refer to the following steps to check for blockages
continuing with each step until the blockage is found:

Check fullness of dirt cup; empty if needed.

Checking Airflow Path

Plug cleaner in and turn ON. Check for suction at end of
hose (A) (Fig.7/1). If there is suction, continue with next
step.

Turn cleaner OFF and unplug. Check connection at hose
tube (B); remove any blockage.

Checking Airflow Path Through Hose Inlet Tube on
Back of Cleaner

Turn cleaner OFF and unplug.

If blockage can be seen in tube (A), remove 5 screws using
a Phillips screwdriver. Pull tube from cleaner, remove
blockage (Fig.7/2).

Reposition tube on back of cleaner, replace 5 screws.

Checking Under Hood

Turn cleaner OFF and unplug.

Remove hood, belt and brushbar as described in previous
section. Look into opening (A) for blockages and remove
(Fig.7/3).

Replace belt, brushbar and hood.

If a Blockage Occurs During TurboTool Use

Disconnect TurboTool from hose. Remove bottom plate,
belt guard and turbine as described in previous section.

Remove any blockage from turbine channel (A) (Fig.7/4).

Replace belt turbine, brush roll, belt guard and bottom plate.

!

Fig.7/1

Fig.7/2

Fig.7/3

Fig.7/4

A

A

A

B

Содержание VZL-6015

Страница 1: ...ays fully extend the mains cable before use Retain for future reference Vax careline 0870 6061248 Bagless upright 5 1 8 7 9 11 10 15 14 12 13 17 18 19 20 21 25 22 23 24 21 16 6 4 3 2 26 27 Vax model n...

Страница 2: ...event damage to lino parquet and other hard flooring See page 5 details Vax will not be held responsible for damage to hard floors including lino if the customer fails to switch the brush bar off on t...

Страница 3: ...rette butts matches or any hot smoking or burning objects 12 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours...

Страница 4: ...er base Fig 3 3 Using a Phillips screwdriver fasten 3 screws located at the bottom of the upper housing Fig 3 4 Place bottom of dirt container into cleaner body first Pivot container into cleaner body...

Страница 5: ...igning with opposite end of plug and push firmly UNTIL YOU HEAR A SNAP OR A CLICK Fig 3 10 After ends are connected pull on plug to make sure it is securely attached NOTE The plug will only fit togeth...

Страница 6: ...To turn cleaner ON push ON OFF switch once To turn cleaner OFF push switch again Fig 4 1 The cleaner is shipped with the brushbar in the OFF position To turn the brushbar ON step on the pedal A The i...

Страница 7: ...room put handle in upright position tilt cleaner back on rear wheels and push forward Fig 4 5 Carrying Cleaner The cleaner can also be moved by using the carrying handle Fig 4 6 Handle Positions The...

Страница 8: ...shown and will prevent rug from clinging to cleaner Fig 4 11 Continue to lift up nozzle so that when you have reached the edge it is completely off the rug Move cleaner back to start again lower nozz...

Страница 9: ...rs and carpeted stairs Crevice tool may be used in tight spaces corners and along edges in such places as dresser drawers upholstered furniture stairs and baseboards Extension tubes are used to give e...

Страница 10: ...ctrical outlet Do not use the cleaner without dirt cup or filters in place Press dirt cup release button A and pivot cup out Fig 5 2 Holding dirt cup over trash receptacle press dirt cup door release...

Страница 11: ...op of the housing to the right and pull down to remove gray filter frame Remove black foam filter Rinse filter frame cartridge and foam filter under cold water Allow both filter frame and filter to ai...

Страница 12: ...e flat wide belt is described below the other belt is described under Brushbar IMPORTANT Disconnect cleaner from electrical outlet Brushbar can start suddenly Unplug cleaner before turning it over To...

Страница 13: ...lowest setting Turn cleaner over and remove bottom plate Lift up brushbar and slide V belt A off brushbar Fig 6 9 Inspecting the V belt The V belt is designed to last for a long time and is not normal...

Страница 14: ...ss the latches on both sides of tool and remove bottom plate A Fig 6 13 Unscrew the two Phillips screws and remove belt guard Fig 6 14 Remove brushbar including end plates A and discard Inspect belt t...

Страница 15: ...placed Remove tool from hose The belt can be seen through the top of the nozzle or by removing the bottom plate and belt guard Fig 6 19 Remove tool from hose Remove bottom plate belt guard and brushba...

Страница 16: ...age Checking Airflow Path Through Hose Inlet Tube on Back of Cleaner Turn cleaner OFF and unplug If blockage can be seen in tube A remove 5 screws using a Phillips screwdriver Pull tube from cleaner r...

Страница 17: ...refer to section 7 PROBLEM Cleaner hard to push Cause Incorrect carpet height setting Solution Move carpet height adjuster to higher setting PROBLEM Smoky burning smell detected Cause Belt broken or...

Страница 18: ...cification 10 Technical Specification Voltage 220 240V 50Hz Wattage 1500W Capacity 2 6l Filters Washable pre motor filter assembly HEPA post motor assembly Cord Length 8 3m Weight 10 68kg Subject to t...

Страница 19: ...19 Vax Careline 0870 606 1248 This page has been left intentionally blank...

Страница 20: ...with the following Directives Safety 2006 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste P...