manualshive.com logo in svg
background image

23 

 
 
 
 

8 - MAINTENANCE

 

 

 

 

(

Turn the key, remove it from the control panel 

and  disconnect  the  battery  from  the  machine 

wiring.

 

(

All work on the electrical system as well as all

 

maintenance  and  repair  operations  (especially

 

those not explicitly described in this manual) should 

be carried out only by Vax service technicians.

 

 

Performing  regular  maintenance  on  the  machine, 

and  carefully  following  the  manufacturer’s 

instructions,  is  the  best  guarantee  for  obtaining 

the  best  performances  and  extended  machine 

service life.

 

 

8.1

 

TANKS

 

Drain  the  two  tanks  as  described  in  the  relative 

sections.

 

Remove  any  solid  dirt  by  filling  and  draining  the 

tanks  until  all  dirt  has  been  eliminated:  use  a 

washing hose or similar tool to do this.

 

(

!

) Water hotter than 50°, a high-pressure

 

cleaner or excessively powerful sprays may

 

damage the tanks and the machine.

 

Leave the plugs of the tanks open (only while the 

machine is not being used) so that they can dry and 

thus prevent the formation of foul odors.

 

 

8.2

 

SOLUTION FILTER CLEANING

 

Remove  the  transparent  cap  (Photo  29  -  A)  then 

remove the metal strainer.

 

Clean them, reinstall the metal strainer in its seat 

and close the water filter screwing the transparent 

cap.

 

 

8.3

 

SUCTION HOSE

 

Detach the suction hose from the squeegee (Photo 

23 - B). Now you can wash the hose and remove 

any obstructions.

 

Firmly insert the hose on the squeegee body.

 

 

8.4

 

SQUEEGEE

 

(

!

Do not handle the squeegee with bare  hands: 

wear  gloves  and  any  safety  clothing  needed  to 

carry  out  the  operation  (as  determined  by 

appropriate risk assessment). 

 

Detach the squeegee from the machine and clean 

it  under  running  water  using  a  sponge  or  a  soft

 

brush.  Check  the  efficiency  and  the  wear  on  the 

strips  in  contact with the floor. They are designed 

to  scrape  the film of  detergent and  water  on  the 

floor and to  isolate that  portion of the  surface  to 

enhance  the  vacuum  of  the  suction  motor:  this 

ensures  that  the  machine will dry very  efficiently. 

Working constantly  in this manner tends to round 

or to deteriorate the  sharp edge of the strip, thus 

reducing  drying  efficiently.  This  is  why  the 

squeegee strips must be replaced.

 

To replace the worn blades, follow the instructions 

in the  relative section. Turn  the blades around to 

wear down the other sharp corners or to install new 

ones.

 

 

8.5

 

ACCESSORIES

 

Remove  and  clean  the  brush  or  the  abrasive  pad 

disk. 

 

(

!

To avoid damaging the floor and the machine,

 

carefully check if foreign matter, such as metallic

 

parts, screws, chips, cords or similar items, has be- 

come jammed. 

 

Check that the brushes are flat as they work on the 

surface  (check  for  any  irregular  wear  on  the 

brushes  or  on  the  abrasive  disks).  If  necessary, 

adjust the slant of the action on the floor.

 

 

Use  only  the  accessories  recommended  by  the 

manufacturer:  other  products  may  reduce 

operating safety.

 

 

8.6

 

MACHINE BODY

 

Use a sponge or a soft cloth to clean the exterior of 

the  machine  and,  if  necessary,  a  soft  brush  to 

eliminate  tough  dirt.  The  machine’s  shockproof 

surface  is rough to make it harder to see scratches 

caused  during use. However, this does not make it 

easier to  remove tough stains on the surface. It is 

prohibited  to  use  steam  machines,  hoses 

with  running  water  and  high-pressure 

cleaners.

 

 

8.7

 

BATTERIES*

 

PB-Acid batteries

 

Carry  out  maintenance  operations  in  accordance 

with the manufacturer’s instructions and with all the 

other instructions provided in this manual. 

 

Exposing  the  element  plates  (not  completely 

immersed  in  the  acid  solution)  will  lead  to  rapid 

oxidation  and  irreparably  reduce  the  element’s 

operating capacities. 

 

An overflowing  acid solution may corrode the ma- 

chine. 

 

Use  battery  chargers  recommended  by  the 

manufacturer  and,  in  any  case,  those  that  are 

suitable  for the type of battery to be charged.

 

Always  charge  batteries  in  well-ventilated  rooms: 

there is an explosion risk! 

 

The  use  of  gel  or  maintenance-free  batteries  is 

highly recommended.

 

 

GEL batteries

 

Carry  out  maintenance  operations  in  accordance 

with the manufacturer’s instructions and with all the 

other instructions provided in this manual.

 

Use  only those  battery  chargers  recommended  by 

the manufacturer.

 

* Only applies to VCSD-02 model 

Содержание VCSD-01

Страница 1: ...0121 347 6047 sales vaxcommercial co uk vaxcommercial co uk User Guide VCSD 01 Mains Powered Scrubber drier VCSD 02 Battery Powered Scrubber drier...

Страница 2: ...2...

Страница 3: ...NT 7 9 FILLING AND DRAINING THE SOLUTION TANK 7 10 DRAINING THE RECOVERY TANK 7 11 ADJUSTING THE SOLUTION WATER FLOW 7 12 DRIVING THE MACHINE 7 13 WORK METHOD 7 13 1 PREPARATION AND WARNINGS 7 13 2 BA...

Страница 4: ...us damage to the machine and to the environment in which it operates DANGER SYMBOL Vital information provided to avoid serious or extreme consequences affecting the health of persons and causing damag...

Страница 5: ...n 2 For small slopes do not use the machine sideways always handle it with caution and never move back wards When transporting the machine on steeper ramps or slopes be very careful to avoid tipping a...

Страница 6: ...gs carpeting etc If foaming or leakages occur immediately turn off the suction motor Wax foaming detergents or dispersions along the hoses may cause serious problems for the machine or clog the hoses...

Страница 7: ...se identified by a qualified risk assessment The machine is packed with in a cardboard housing placed on a wooden crate to unpack the machine carry out the following steps Use scissors or clippers to...

Страница 8: ...BOLS USED ON THE MACHINE General ON OFF switch Brush motor switch Suction motor switch Solenoid valve switch Symbol of the solution water flow adjustment Symbol of the recovery tank drain hole Symbol...

Страница 9: ...ery water tank C Suction compartment cover D Solution water tank A Suction filter B Automatic shut off float C Recovery tank inspection plug B A A Control lever Photo 2 A Handlebar release pedal B Squ...

Страница 10: ...et D Brush motor switch A Suction motor switch B Solenoid valve switch for solution water outlet C Brush motor switch C A Power supply cable A General ON OFF key battery cut out switch B Protecting ca...

Страница 11: ...5 TECHNICAL INFOMATION 11 5 3 DIMENSIONS All dimensions are in centimetres 114 81 79...

Страница 12: ...bar opened it is necessary to operate the handlebar release pedal Photo 9 A press the pedal pull the handlebar towards you and place it in the appropriate working position The handlebar can be set in...

Страница 13: ...onnection diagram in Photo 15 Take care to avoid short circuits over the battery terminals After checking that all the controls on the panel are in position 0 or at rest connect the battery connector...

Страница 14: ...k in continuous and parallel rectangular areas Choose a straight work trajectory and begin working from the farthest area to avoid passing over areas that have already been cleaned 7 2 BATTERY CHARGIN...

Страница 15: ...f the abrasive disks to become less than 1 cm Working with excessively worn brushes or excessively thin abrasive disks may damage the machine and the floor Regularly check the wear on these parts befo...

Страница 16: ...knob A B A Photo 23 A Squeegee fixing pin B Suction hose coupling pipe 7 7 SQUEEGEE BLADES DISASSEMBLY AS SEMBLY Disassemble the squeegee from its support see 7 5 Unscrew the knobs Photo 24 A and remo...

Страница 17: ...possible to rotate the wheel up or down and move the blade When the squeegee is perfectly adjusted the rear squeegee blade sliding as it moves bends in all points forming an angle of 45 with the floo...

Страница 18: ...d get sensitive parts of the machine wet Close the tank with its foam plug A Photo 28 A Solution tank filling opening To drain the tank Unscrew the cap of the water filter placed in lower part of the...

Страница 19: ...in plug 7 11 ADJUSTING THE SOLUTION WATER FLOW To adjust the flow of the solution water it is necessary to operate the water valve placed over the brush unit Set the solution flow control lever in an...

Страница 20: ...WORK METHOD 7 13 1 PREPARATION AND WARNINGS Remove any loose solid residue from the surface to be treated using suitable tools such as vacuum cleaners sweepers etc If this is not done the solid dirt...

Страница 21: ...tric cables that are defective or worn Before gaining access to the electrical system it is always necessary to disconnect the machine from the electrical source In the case of defective damaged or cr...

Страница 22: ...er tends to round or to deteriorate the sharp edge of the strip thus reducing drying efficiently This is why the squeegee strips must be replaced To replace the worn blades follow the instructions in...

Страница 23: ...the profile of the squeegee blades and replace them if necessary Check that the suction hoses and conduits are not clogged Thoroughly clean the solution and recovery tanks For other models with the P...

Страница 24: ...case replace the motor 9 5 INSUFFICIENT SUCTION L The cover of the suction compartment is not perfectly closed J Close it correctly L The suction hose or the squeegee conduit are obstructed J Clean ou...

Страница 25: ...d with by unauthorised third parties the warranty shall be considered void The warranty shall also be considered void if the user is not able to produce an original legible and complete document provi...

Страница 26: ...27 Vax Commercial Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 0QH UK info vaxcommercial co uk vaxcommercial co uk...

Отзывы: