background image

         5

operation / accessories

Window attachment

- Push the window attachment

onto the rectangular steam nozzle until you hear it click
into place. You can fit the window attachment to the
concentration nozzle by pushing it into place. 

Perfect for cleaning windows, mirrors, ceramic tiles and
surfaces and other non-porous, smooth surfaces.

Apply the steam evenly to the glass surface from a

distance of about 20cm. Switch the steam off and wipe
the moisture off the glass top to bottom in strips using
the  rubber squeegee. Wipe the rubber squeegee and the
lower edge of the window dry after every strip.

WARNING: 

Glass surfaces can be shattered by the

sudden application of excessive heat. Before
cleaning such glass surfaces with the steam

cleaner. warm them up by applying steam to the surface
from a distance of 20-25cm. Continue by applying steam
from a distance of 10-15cm.

4. How to Operate

Over-heating protection

The steamer is equipped with protection against over-
heating. The cleaner will switch itself off automatically
on reaching a temperature of 180˚C, in order to prevent
over-heating. In this event, please remove the plug from
the socket immediately. Allow the cleaner to cool down
for 30 minutes before resuming work.

Filling the water tank

Always ensure that the plug of the steamer is removed
from the socket before filling or refilling the cleaner with
water.  Remove the cover of the water tank by pressing it
down and turning it anti-clockwise. Fill the tank with 1.4L
of water using the measuring beaker. Replace the cover
and close it tightly by turning in the clockwise direction.
The water tank should be emptied after use. Allow the
inside of the water tank to dry out before replacing the
cover.

If the water tank needs to be refilled during use, first
switch the cleaner off and remove the plug from the
socket. Before opening the tank cover to refill the tank,
release the steam switch on the steam gun or allow the
cleaner to cool down completely.

WARNING: 

Even after a cooling period of 5

minutes, the remaining water in the tank and the

tank cover locking screw will still be hot. Always take care
when removing the tank cover locking screw, since hot
steam may be emitted and the thread can still cause
burns. The filler opening of the cleaner must never be
opened during use (CONTAINER UNDER PRESSURE).

WARNING: 

Never fill the tank with anything but

cold water. The use of any other fluids can be

dangerous, and can lead to damage of the heating
element. 

Vax Careline

: (UK) 0844 412 8455

(ROI) 1-800 928 308

!

!

!

!

!

!

!

!

!

!

!

!

water

All manuals and user guides at all-guides.com

Содержание V-085 Series

Страница 1: ...ys fully extend the mains cable before use Retain for future reference Vax Careline UK 0844 412 8455 ROI 1 800 928 308 instruction manual Steam cleaner Vax model number V 085 Series Version 1 0 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...el 10 Hose 11 Steam gun 12 Connection nozzle 13 Steam switch 14 Lock child safety 15 Accessory attachment button 16 Extension tubes 17 Release button 18 Floor nozzle 19 Cloth holder 20 Large cloth 21 Accessory adaptor 22 Concentration nozzle 23 Jet nozzle attachment 24 Round brush plastic bristles 25 Round brush metal bristles 26 2 in 1 combi attachment Rectangular steam nozzle and window attachme...

Страница 3: ... 22 Do not operate the steam cleaner without water in the tank Always top up with water in good time 23 Empty the water tank when the steam cleaner is not in use 24 Never fill the tank with anything other than water Never put additives such as perfume stain remover or products containing alcohol in the water as they may damage the steam cleaner or make it dangerous to use 25 Always remove the main...

Страница 4: ...ration nozzle is pushed directly onto the accessory adaptor until it clicks into place It can be used with various fittings jet nozzle attachment brush attachment 2 in 1 combi nozzle depending on the task Jet nozzle attachment The jet nozzle attachment can be fitted directly to the concentration nozzle Push and twist to fit Ideal for hard to reach places such as corners and joints Brush attachment...

Страница 5: ...wn for 30 minutes before resuming work Filling the water tank Always ensure that the plug of the steamer is removed from the socket before filling or refilling the cleaner with water Remove the cover of the water tank by pressing it down and turning it anti clockwise Fill the tank with 1 4L of water using the measuring beaker Replace the cover and close it tightly by turning in the clockwise direc...

Страница 6: ... micro fibre or cotton cloth if necessary this will also remove any excess moisture for thorough cleaning In order to control the steam temperature and cleaning power at the surface move the steam gun closer to or further away from the surface After use WARNING Before opening the tank cover to empty the tank release the steam pressure by pressing the steam switch on the steam gun or allow the clea...

Страница 7: ...tank is empty Solution Top up with water PROBLEM Only a very small amount of steam flows out Cause The steam controller is set to minimum Solution Turn the steam controller anticlockwise until sufficient steam is emitted PROBLEM The steam cleaner takes a very long time to heat up Cause The water tank is furred up Solution Descale the water tank 7 UK Service Help Vax Careline UK 0844 412 8455 ROI 1...

Страница 8: ...ow Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website vax co uk All manuals and user guides at all...

Отзывы: