Do not tip or tilt the steam cleaner by more than 45°
during use and ensure that the appliance always stands
on a firm base. One full tank is enough for a maximum of
50 minutes use. Do not leave the machine unsupervised
while switched on and if necessary use the child-proof
lock to secure the steam switch. To do this, press the
triangular pin on the left-hand side of the steam gun in
to the right.

IMPORTANT

: The housing and accessories

become hot during operation. Allow the steam
cleaner to cool down before changing the

accessories. Never open the tank cap whilst the steam
cleaner is switched on as the tank is under pressure.

Topping Up with Water

The tank must be topped up if the steam flow emitted
starts to decrease. Switch off the steam cleaner by
pressing the on/off switch. The green operating pilot
lamp goes off. Press the steam button on the steam gun
to release the remaining pressure and then lock the gun.
Remove the mains plug from the socket and allow the
appliance to cool down. Vax recommend allowing the
steam cleaner to cool for at least 15 minutes. Open the
tank cap by pressing it down and turning it anti-
clockwise.

WARNING

: Hot steam may escape on opening.

There is a risk of burns from the cap thread and

the tank.

Top up with water using the measuring jug and funnel
then carefully close the tank cap again. The steam
cleaner can now be plugged in again and switched on.
The steam cleaner is ready for use as soon as the heating
pilot lamp goes off.

5. Accessories

Floor Nozzle

Attach the floor nozzle to the end of the extension tube.
Ensure that the nozzle clicks into place on assembly
(Fig.5/1).

The floor nozzle is ideal for cleaning washable wall and
floor coverings. It may be used with or without the
cleaning cloth. However, Vax recommend using the cloth
to protect coverings in the case of sensitive surfaces
such as wood or linoleum.

Place the floor nozzle on the cleaning cloth and secure
the overhanging material under the cleaning cloth clips
on the left and right. Press on the inner sides of the
holder, then open the clips and the cleaning cloth can be
secured in place (Fig.5/1).

To take the floor nozzle off again, press in the
appropriate release button (see Fig.5/2) and pull the
nozzle off with a downward movement.

MIN

MAX

Fig.4/6

Fig.5/1

Fig.5/2

!

!

Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308

V-081 Series User Guide.qxd:User Guide  22/4/10  17:26  Page 7

All manuals and user guides at all-guides.com

Содержание V-081 SERIES

Страница 1: ...use Retain for future reference instruction manual Steam Cleaner Vax model number V 081 Series compact cleaner Vax Careline UK 0844 412 8455 ROI 1 800 928 308 Version 1 0 V 081 Series User Guide qxd U...

Страница 2: ...attachment 7 Nylon brush 8 Metal brush 9 2 in 1 attachment steam attachment 10 Cotton cover 11 2 in 1 attachment window attachment 12 Large cleaning cloth 13 Floor nozzle 14 3 extension tubes 15 Stea...

Страница 3: ...eaner without water in the tank Always top up with water in good time 23 Empty the water tank when the steam cleaner is not in use 24 Never fill the tank with anything other than water Never put addit...

Страница 4: ...ssories compartment off towards the front Figs 3 1 and 3 2 the cover Slide the nose of the cover into the recess above the steam socket and press it down firmly at the back until the cover clicks into...

Страница 5: ...without additives of any kind e g perfume cleaning agents alcohol as they could damage the machine and make it dangerous to use It is advisable to use limescale deposits if your water is very hard ove...

Страница 6: ...nly Cleaning can now begin NOTE Always test the steam cleaner first on inconspicuous or invisible areas of the surfaces or fabrics to be cleaned to check their tolerance to hot steam Steam may result...

Страница 7: ...wn and turning it anti clockwise WARNING Hot steam may escape on opening There is a risk of burns from the cap thread and the tank Top up with water using the measuring jug and funnel then carefully c...

Страница 8: ...the sequence to take the detail nozzle off again twist the nozzle a quarter turn in the opposite direction to the arrow and pull it off with a downward movement Jet Nozzle Simply push the jet nozzle f...

Страница 9: ...alcohol since they may damage the housing Vax recommend that the tank be rinsed out after 5 filling operations at the latest if water hardness is above 1 8 mmol l 10 dH Information regarding local wat...

Страница 10: ...perating pilot lamp fails to light Cause The steam cleaner is not plugged into a socket or is not switched on Solution Insert the mains plug into a socket or switch the steam cleaner on Cause The sock...

Страница 11: ...and model For the nearest Service Agent please call the Vax Careline vax co uk 10 Technical Specification Voltage 220 240V 50Hz Wattage 1500 W Steam pressure 3 5 bar max Permissible pressure 5 bar Wat...

Страница 12: ...108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retaile...

Отзывы: