background image

7

Vax Careline

0870 606 1248

dirt container & filter / maintenance

The HEPA filter may be washed by running it under the
tap. We recommend washing it once a month or when
suction appears reduced. Always allow to air dry for 24
hours before replacing into the vacuum.

PLEASE NOTE:

The white material in the HEPA filter will

discolour over time -This is NORMAL and will NOT affec
tthe performance of the filter.

WARNING:

Always empty the dirt container and

clean the HEPA filter before each use and during
prolonged usage. Never over fill the dirt container,

remove dirt and clean the HEPA filter each time the dirt
container is emptied during prolonged usage or risk motor
damage.

Cleaning the Pre-Motor Filter

Underneath the dirt container is a pre-motor filter. If found
to be defective, please replace (Fig.6/4).

Cleaning the Dirt Container

WARNING:

To reduce the risk of electric shock, the

power cord must be disconnected before removing

the dirt container, HEPA filter, changing the filters or
performing maintenance/troubleshooting checks.

• The dirt container can be washed in lukewarm water
(max 40ºC).

• Do not use strong detergents.

• Ensure that the dirt container is fully dry before putting
back on the vacuum cleaner. Do not wash in dishwasher.

7. Maintenance

Cleaning and Changing the Belt

TOOLS REQUIRED: Phillips screwdriver.

WARNING:

To reduce the risk of electric shock, the

power cord must be disconnected before removing
the dirt container, HEPA filter, changing the filters

or performing maintenance/troubleshooting checks.
Occasionally, the power nozzle drive belt will require
changing, the frequency will depend upon the amount of
vacuum use.

Turn vacuum off and unplug from power supply. Press
handle release button and lay vacuum cleaner on a flat,
level surface.

Using a Phillips screwdriver, remove the four (4) screws on
the underside of the cleaner to release the top cover of
the vacuum head (Fig.7/1).

Lift the right side of the brushbar and lift the left hand
side and remove the brushbar from the power head
(Fig.7/2).

Remove the worn or broken belt from the motor drive
shaft.

Carefully remove any belt residue that may exist in the belt
area before replacing with a new belt.

Loop the new belt first over the motor drive shaft and
then over the agitator pulley.

Fig.6/4

Fig.7/1

Fig.7/2

!

!

!

V-044B Infinity By Vax User Guide.qxd:V-044B Infinity User Guide  18/6/09  16:04  Page 7

Содержание Ultra handvac

Страница 1: ...ly rotating brush bar which when left in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax recommends that you raise the height of the...

Страница 2: ...release pedal 20 Two 2 short screws 21 Two 2 long screws 1 2 14 15 16 10 5 12 13 17 6 9 3 4 7 8 20 21 WARNING This cleaner has a constantly rotating brush bar which when left in contact with lino par...

Страница 3: ...es or any hot smoking or burning objects 13 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours 14 Do not vacuum...

Страница 4: ...ontainer push the top in place there will be an audible click when it is secure Fig 3 3 Assembly of the Hose Align the tabs on the lower hose inspection tube with the slots on the hose Push and turn t...

Страница 5: ...until the vacuum is comfortable to push The brushbar must reach the carpet for effective cleaning Fig 4 3 IMPORTANT When the vacuum cleaner is stood in the upright position or when using the hose and...

Страница 6: ...outlet before opening the dirt container IMPORTANT Do NOT use the vacuum without the HEPA filter in place To remove the dirt container press the dirt container release button and lift away from the v...

Страница 7: ...max 40 C Do not use strong detergents Ensure that the dirt container is fully dry before putting back on the vacuum cleaner Do not wash in dishwasher 7 Maintenance Cleaning and Changing the Belt TOOLS...

Страница 8: ...cleaner Leave for one 1 hour before switching the vacuum cleaner back on Cause Blown fuse tripped breaker Solution Reset circuit breaker or replace fuse PROBLEM Cleaner won t pick up loss of suction C...

Страница 9: ...ng There are over 400 approved Vax Service Agents in the UK For the nearest Service Agent please call the Vax Careline vax co uk 10 Technical Specification Voltage 230 240V 50Hz Wattage 1400 1500W Cap...

Страница 10: ...www vax co uk 10 This page has been left intentionally blank V 044B Infinity By Vax User Guide qxd V 044B Infinity User Guide 18 6 09 16 04 Page 10...

Страница 11: ...11 Vax Careline 0870 606 1248 This page has been left intentionally blank V 044B Infinity By Vax User Guide qxd V 044B Infinity User Guide 18 6 09 16 04 Page 11...

Страница 12: ...C Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for...

Отзывы: