background image

GROUNDING INSTRUCTIONS 

This appliance must be grounded.  If it should malfunction or breakdown, grounding provides 
a path of least resistance for electric current to reduce the risk of electric shock.  This 
appliance is equipped with a cord having an equipment-grounding conductor and grounding 
plug.  The plug must be inserted into an appropriate outlet that is properly installed and 
grounded in accordance with all local codes and ordinances. 

WARNING

Improper connection of the equipment-grounding conductor can result in a risk of electric 
shock.  Check with a qualified electrician or service person if you are in doubt as to whether 
the outlet is properly grounded.  Do not modify the plug provided with the appliance – if it will 
not fit the outlet, have a proper outlet installed by a qualified electrician. 

This appliance is for use on a nominal 120-volt circuit, and has a grounded plug that looks 
like the plug illustrated in sketch A.  A temporary adaptor that looks like the adaptor 
illustrated in sketches B and C may be used to connect this plug to a 2-pole receptacle as 
shown in sketch B if a properly grounded outlet is not available.  The temporary adaptor 
should be used only until a properly grounded outlet (sketch A) can be installed by a 
qualified electrician.  The green colored rigid ear, lug, or the like extending from the adaptor 
must be connected to a permanent ground such as a  properly grounded outlet box cover.  
Whenever the adaptor is used, it must be held in place by a metal screw. 

Note: In Canada, the use of a temporary adaptor is not permitted by the Canadian Electrical 
Code.

GROUNDING 
PIN

GROUNDED
OUTLET

ADAPTER

METAL SCREW

TAB FOR 
GROUNDING SCREW

GROUNDED
OUTLET BOX

(A)

(B)

(C)

Содержание U-Vac UPV12

Страница 1: ...86039870 J 11 14 13 PRV NO 980188 For commercial use only Para uso comercial solamente MODEL UPV12 10120330...

Страница 2: ......

Страница 3: ......

Страница 4: ...have a proper outlet installed by a qualified electrician This appliance is for use on a nominal 120 volt circuit and has a grounded plug that looks like the plug illustrated in sketch A A temporary...

Страница 5: ...ente adecuada El aparato est dimensionado para su conexi n a una red de 120 Voltios de tensi n nominal y cuenta con un enchufe con clavija de puesta a tierra como el que se muestra en la figura A Si n...

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ...CENTURY 400 325 Price Road Chandler AZ 85224 4934 Phone 800 776 2436...

Страница 12: ...PARTS LIST U VAC UPV12 120V...

Страница 13: ...CH SPRING 23 86141880 5809CT FRONT COVER CPL 24 86000500 5300 SENSOR FILTER BAG PACK 25 86005220 5301ER MICRO HYGIENE FILTER 26 86142900 5380DG INTERNAL COVER DK GRY 27 86139290 5164 CABLE CLAMP 28 86...

Страница 14: ...PARTS LIST U VAC UPV12 120V PARTS LIST U VAC UPV12 120V...

Страница 15: ...130 86143910 5174DG PILE ADJUSTMENT WHEEL 131 86137920 2849 AXLE CLAMP 132 86144860 01010 SCREW M 4 x 6 DIN 7985 133 86140620 2860HG COVER 134 86146220 2833 THRUST MEMBER 135 86143890 2862HG PILE ADJU...

Страница 16: ...NOTES...

Страница 17: ...E Parts Service Labor Travel Ninja Sensei Spot Plus Hurricane and Turbo Mist 10 years 1 year 90 days None Polishers Elec Burnishers 3 years 90 days None All others 5 years 1 year 90 days None UPV12 Up...

Страница 18: ...ary to correct any failure due to improper pre delivery service and inspection by the selling dealer 5 Time for cleaning units in preparation for repair 6 Any repairs resulting from poor initial servi...

Страница 19: ...locar su producto vaya www century400 com support warranty register php Para la ayuda del cliente 1 800 776 2436 Warranty Registration Thank you for purchasing a C400 product Warranty registration is...

Страница 20: ...86039870 J 06879 11 14 13...