3. Lift the right side of the brushbar and lift the left
hand side and remove the brushbar from the power
head (Fig.7/3).
4. Remove the worn or broken belt from the motor
drive shaft.
5. Carefully remove any belt residue that may exist in
the belt area before replacing with a new belt.
6. Loop the new belt first over the motor drive shaft
and then over the agitator pulley.
7. Insert the right side of the brushbar in first by
placing the end cap down in the slot and then so
the same with the left side. Press firmly to make
sure that each end is completely inserted.
8. Check to make sure that the belt is centred on the
agitator pulley and that the brushbar turns.
9. Replace the vacuum head cover by screwing in the
four (4) screws on the underside of the vacuum
cleaner.
Fig.7/3
Fig.7/2
Maintenance
Vax V-047 10th.qxd 3/10/05 4:14 PM Page 8